Laserfiche WebLink
Appendix D <br />Standard Specifications for Grading <br />Page D-4 <br />6.2 Cut Slopes <br />Unless otherwise recommended by the geotechnical consultant and approved by the <br />regulating agencies, permanent cut slopes should not be steeper than 2:1 (horizontal: <br />vertical). <br />The geotechnical consultant should observe cut slope excavation and if these excavations <br />expose loose cohesionless, significantly fractured or otherwise unsuitable material, the <br />materials should be overexcavated and replaced with a compacted stabilization fill. If <br />encountered specific cross section details should be obtained from the Geotechnical <br />Consultant. <br />When extensive cut slopes are excavated or these cut slopes are made in the direction of <br />the prevailing drainage, a non -erodible diversion swale (brow ditch) should be provided <br />at the top of the slope. <br />Al Part Areae <br />All lot pad areas, including side yard terrace containing both cut and fill materials, <br />transitions, located less than 3 feet deep should be overexcavated to a depth of 3 feet and <br />replaced with a uniform compacted fill blanket of 3 feet. Actual depth of overexcavation <br />may vary and should be delineated by the geotechnical consultant during grading, <br />especially where deep or drastic transitions are present. <br />For pad areas created above cut or natural slopes, positive drainage should be established <br />away from the top -of -slope. This may be accomplished utilizing a berm drainage swale <br />and/or an appropriate pad gradient. A gradient in soil areas away from the top -of -slopes <br />of 2 percent or greater is recommended. <br />Section 7 - Compacted Fill <br />All fill materials should have fill quality, placement, conditioning and compaction as specified <br />below or as approved by the geotechnical consultant. <br />7.1 Fill Material Quality <br />Excavated on-site or import materials which are acceptable to the geotechnical consultant <br />may be utilized as compacted fill, provided trash, vegetation and other deleterious <br />materials are removed prior to placement. All import materials anticipated for use on-site <br />should be sampled tested and approved prior to and placement is in conformance with the <br />requirements outlined. <br />STANDARD SPECIFICATIONS OF GRADING <br />Page 4 of 26 <br />