Period Influent Effluent
<br />Hourmeter Totalizer System Volume Average Flow Well Field System Flow VOC VOC VOC1
<br />Reading Reading Flow Discharged Flow Rate Rate Temperature Vacuum Rate [FID] [FID] Removed
<br />Date (hours) (gal) (gal) (gal) (gal/day) (gpm)(oF)(inHg) (scfm) (ppmv) (ppmv) (lb/day)pH12 Notes
<br />Table 10
<br />Dual Phase Extraction System - Operating Data
<br />Parcel 2A - L&M OU
<br />666 West Weber Avenue, Stockton, CA
<br />Operating
<br />Temperature
<br />(oF)
<br />10/27/11 5,080.1 4,809,873 6,702,563 53,063 2,645 1.84 -- 631 -- 116.0 420.0 0.0 7.9 7.42 17
<br />11/15/11 5,081.7 4,813,770 6,706,460 3,897 205 0.14 -- -- -- -- -- -- -- 7.60
<br />12/15/11 5,081.7 4,815,174 6,707,864 1,404 47 0.03 -- -- -- -- -- -- -- 7.80
<br />01/19/12 5,081.7 4,815,230 6,707,920 56 2 0.00 -- -- -- -- -- -- -- 8.42
<br />02/28/12 5,081.7 4,817,956 6,710,646 2,726 68 0.05 -- -- -- -- -- -- -- 7.13
<br />03/16/12 5,082.3 4,818,886 6,711,576 930 55 0.04 -- -- -- -- -- -- -- 7.96
<br />Current Reporting Period:Cumulativie Totals: March 18, 2004 through March 16, 2012
<br />Number of Hours Operated During Reporting Period: 0.6 hours Number of Days of Operation 1,564 days
<br />Total Gallons Processed During Reporting Period: 3,712 gallons Total Gallons Extracted 6,711,576 gallons
<br />Average Flow Rate (gpm) During Reporting Period: -- gpm Average Flow Rate (gpm) 2.98 gpm
<br />Period Percent Operational: 0%
<br />Constituent Historical Liquid
<br />lbs. gals lbs. gals lbs. gals lbs. gals lbs. lbs. gals
<br />SPH -- -- -- 5.81 -- 5.81 -- -- -- -- --
<br />TPHd 0.00 0.00 0.04 0.01 0.04 0.01 8.1 1.12 9,534 9,543 1,329
<br />TPHo -- -- 0.02 0.00 0.02 0.00 -- -- 5,136 5,136 674
<br />TPHg 0.00 0.00 0.01 0.00 0.01 0.00 17,872 2,930 152 18,023 2,955
<br />Benzene 0.00 0.00 0.00 0.00 0.00 0.00 11.89 1.62 0.07 11.97 1.62
<br />MtBE 0.00 0.00 0.00 0.00 0.00 0.00 3.44 0.56 0.02 3.47 0.56
<br />TBA -- -- 0.00 0.00 0.00 0.00 -- -- 0.52 0.52 0.08
<br />Equation:
<br />X [86.17 (g/mole)] X [1 lbs/453.59 g] X [1.2641 moles/1 cf] X [Avg of consecutive flow rates (scfm)] X [60 min/hr] X [24 hr/day]
<br />Definitions:
<br />gal = gallons scfm = standard cubic feet per minute PAH = Polycyclic Aromatic Hydrocarbons
<br />gpm = gallons per minute VOC = Volatile Organic Compound acfm = actual cubic feet per minute
<br />oF = degrees Fahrenheit ppmv = parts per million by volume GAC = Granular Activated Hydrocarbon
<br />inHg = inches of Mercury gal = gallons
<br />gpm = gallons per minute ATC = Authority to Construct
<br />Notes:
<br />a = System switched to operate in catalytic mode
<br />b = System switched to operate in thermal mode.
<br />- Column under heading VOC (Hexane) Removed (lb/day)added 2Q10 to track removal rate of total VOCs.
<br />1 = VOC represented as Hexane (molecular weight 86.17) for VOC vapor mass removal rate calculation. Hexane was used because it was most representative of the lower carbon range
<br />organics.
<br />2 = System permitted under ATC number N-4878-1-1. Source test for air board. Extracted groundwater being held in onsite holding tank. System shut down following source test.
<br />3 = System started for 24-hour collection of vapor PAH samples.
<br />4 = System shut down following completion of vapor PAH sample collection. PAH results outside of ATC limits (no detectable PAHs in influent vapor stream); alternate ATC needed to operate.
<br />5 = Approximately 5,840 gallons of groundwater stored in holding tank discharged to sanitary sewer.
<br />6 = ATC Number N-4878-1-2 issued 7/20/2004. System restarted.
<br />7 = Source test for air board. System shut down following source test due to on-site excavation activities.
<br />8 = Samples collected from wastewater treatment system. Carbon change-out needed.
<br />9 = System shut down following completion of vapor PAH sample collection.
<br />10 = System non-operational since 5/2005. No sampling and no discharge activities occurred.
<br />11 = System effluent sampled on 7/6/2005 following startup.
<br />12 = Start-up on fresh GAC
<br />13 = pH measurement recorded in the field beginning December 9, 2009.
<br />14 = Hourmeter and totalizer readings recorded on Feb 4, 2010, all else occurred on Feb 5, 2010.
<br />15 = System shut down on August 28, 2010 due to the failure of the oil-water seperator transfer pump. Repairs were made and the system was restarted on October 4, 2010.
<br />16
<br />17
<br />[Avg of consecutive (Inf Con - Eff Con)(ppmv) ]
<br />VOC Removed/day =------------------------------------------------------
<br />[1,000,000 parts]
<br />= System shut down with regulatory approval for remainder of 4Q11 due to declining influent concentrations. Will be restarted during 1Q12 for rebound testing.
<br />= System hour meter was replaced. DPE wells were closed during pilot test conducted from 11/16/10 to 11/19/10. No well field temperature or flow rate were collected; therefore, values from the most recent visit with the same
<br />system vacuum was used instead (07/12/10).
<br />Historical TotalPeriod Vapor Period Liquid Period Total
<br />December 15, 2011 through March 16, 2012
<br />Historical Vapor
<br />I:\Tidewater\TW Stockton (P2A)\Engineering\O&M\Tables\O&M Tables 2012\Parcel 2A OM Tables 1Q12.xlsx Page 3 of 3
|