Laserfiche WebLink
Glossary of Terms and Qualifiers <br />Work Order Number: <br />Qualifier Definition <br />12-01-1082 <br />See applicable analysis comment.* <br />Less than the indicated value.< <br />Greater than the indicated value.> <br />Surrogate compound recovery was out of control due to a required sample dilution. <br />Therefore, the sample data was reported without further clarification. <br />1 <br />Surrogate compound recovery was out of control due to matrix interference. The <br />associated method blank surrogate spike compound was in control and, therefore, the <br />sample data was reported without further clarification. <br />2 <br />Recovery of the Matrix Spike (MS) or Matrix Spike Duplicate (MSD) compound was out <br />of control due to matrix interference. The associated LCS and/or LCSD was in control <br />and, therefore, the sample data was reported without further clarification. <br />3 <br />The MS/MSD RPD was out of control due to matrix interference. The LCS/LCSD RPD <br />was in control and, therefore, the sample data was reported without further clarification. <br />4 <br />The PDS/PDSD or PES/PESD associated with this batch of samples was out of control <br />due to a matrix interference effect. The associated batch LCS/LCSD was in control and, <br />hence, the associated sample data was reported without further clarification. <br />5 <br />Surrogate recovery below the acceptance limit.6 <br />Surrogate recovery above the acceptance limit.7 <br />Analyte was present in the associated method blank.B <br />Sample analyzed after holding time expired.BU <br />Concentration exceeds the calibration range.E <br />Sample was extracted past end of recommended max. holding time.ET <br />The chromatographic pattern was inconsistent with the profile of the reference fuel <br />standard. <br />HD <br />The sample chromatographic pattern for TPH matches the chromatographic pattern of <br />the specified standard but heavier hydrocarbons were also present (or detected). <br />HDH <br />The sample chromatographic pattern for TPH matches the chromatographic pattern of <br />the specified standard but lighter hydrocarbons were also present (or detected). <br />HDL <br />Analyte was detected at a concentration below the reporting limit and above the <br />laboratory method detection limit. Reported value is estimated. <br />J <br />LCS/LCSD Recovery Percentage is within Marginal Exceedance (ME) Control Limit <br />range. <br />ME <br />Parameter not detected at the indicated reporting limit.ND <br />Spike recovery and RPD control limits do not apply resulting from the parameter <br />concentration in the sample exceeding the spike concentration by a factor of four or <br />greater. <br />Q <br />The sample extract was subjected to Silica Gel treatment prior to analysis.SG <br />% Recovery and/or RPD out-of-range.X <br />Analyte presence was not confirmed by second column or GC/MS analysis.Z <br />Solid - Unless otherwise indicated, solid sample data is reported on a wet weight basis, not <br />corrected for % moisture. All QC results are reported on a wet weight basis. <br />MPN - Most Probable Number <br /> 7440 Lincoln Way, Garden Grove, CA 92841-1427 TEL:(714) 895-5494 FAX: (714) 894-7501..Return to ContentsPage 23 of 29