Laserfiche WebLink
Emergency Response Facilities <br />Fire Station: <br />Police: <br />Lodi Fire Department <br />210 W Elm St <br />Lodi, CA 95240 <br />Telephone: 911 or (209) 333-6735 <br />Lodi Police Department <br />215 W Elm St <br />Lodi, CA 95240 <br />Telephone: 911 or (209) 333-6728 <br />Hospital: Lodi Memorial Hospital <br />975 S Fairmont Avenue <br />Lodi, CA 95240 <br />Telephone: 911 or (209) 334-3411 <br />Poison Control: Lodi Memorial Hospital <br />975 S Fairmont Avenue <br />Lodi, CA 95240 <br />Telephone: 911 or (209) 334-3411 <br />Ambulance: Lodi Memorial Hospital <br />975 S Fairmont Avenue <br />Lodi, CA 95240 <br />Telephone: 911 or (209) 334-3411 <br />DIRECTIONS TO HOSPITAL EMERGENCY ROOM ATTACHED IN APPENDIX A <br />Air Monitoring <br />Air quality in the breathing zone will be monitored continuously with a MiniRae2000 photoionization detector <br />(PID) calibrated to isobutylene. Work will proceed in Level D while PID readings are between 0 and 10 parts per <br />million (ppm). In the event that breathing zone readings exceed 100 ppm, all personnel will discontinue work at <br />the location and withdraw from the work area. The appropriate vapor control measures will be implemented (e.g., <br />application of vapor suppression), the necessary emergency response authorities will be notified, and/or the work <br />area will be re-sampled until vapor levels are within acceptable levels prior to reentering the work zone. <br />Please refer to the table below for the Operational Action Levels. <br />Contaminants Action Level Action to Take <br />VOCs <br />(PID) <br />1 to 10 PPM Above background at the breathing <br />zone and sustained for 5 minutes <br />10 to 100 PPM Above background at the breathing <br />zone and sustained for 5 minutes <br />100 to 300 PPM Above background at the breathing <br />zone and sustained for 1 minute <br />>300 PPM Above background at the breathing zone <br />and sustained for 1 minute <br />Level D, continuous air monitoring <br />Upgrade to Level C, continuous air monitoring and <br />ventilate space <br />Upgrade to Level B, continuous air monitoring and <br />ventilate space, or stop work and ventilate <br />Stop work, Evacuate work zones <br />Combustible <br />Gas in Air <br />(LEL meter) <br />Less than 10% lower explosive limit (LEL) <br />Greater than 10% LEL <br />Continue with caution and air monitoring <br />(combustible gas monitoring) <br />Stop work, immediately withdrawal personnel, and <br />ventilate space with manhole blower <br />Oxygen in Air <br />(02 Meter) <br />Less than 19.5% <br />19.5 to 21.5% <br />Greater than 21.5% <br />Stop work and ventilate or upgrade to Level B <br />Level D, continue work with air monitoring <br />Stop work, immediately withdrawal personnel, and <br />evaluate <br />The PID will be calibrated daily by Partner personnel prior to use. Calibration will be performed in accordance with <br />the manufacturer specifications and recorded in a log book kept with the instrument. Ambient breathing space <br />measurements should be collected every 15 minutes. <br />Partner Site-Specific Health and Safety Plan Page 3 <br />Version 1.02 <br /> June 28, 2017