COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CLUFF
>
54
>
2900 - Site Mitigation Program
>
PR0542041
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2021 12:42:49 PM
Creation date
6/1/2021 12:38:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0542041
PE
2950
FACILITY_ID
FA0024136
FACILITY_NAME
A-1 SAW AND MOTOR INC
STREET_NUMBER
54
Direction
N
STREET_NAME
CLUFF
STREET_TYPE
AVE
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
54 N CLUFF AVE
P_LOCATION
02
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Emergency Response Facilities <br />Fire Station: <br />Police: <br />Lodi Fire Department <br />210 W Elm St <br />Lodi, CA 95240 <br />Telephone: 911 or (209) 333-6735 <br />Lodi Police Department <br />215 W Elm St <br />Lodi, CA 95240 <br />Telephone: 911 or (209) 333-6728 <br />Hospital: Lodi Memorial Hospital <br />975 S Fairmont Avenue <br />Lodi, CA 95240 <br />Telephone: 911 or (209) 334-3411 <br />Poison Control: Lodi Memorial Hospital <br />975 S Fairmont Avenue <br />Lodi, CA 95240 <br />Telephone: 911 or (209) 334-3411 <br />Ambulance: Lodi Memorial Hospital <br />975 S Fairmont Avenue <br />Lodi, CA 95240 <br />Telephone: 911 or (209) 334-3411 <br />DIRECTIONS TO HOSPITAL EMERGENCY ROOM ATTACHED IN APPENDIX A <br />Air Monitoring <br />Air quality in the breathing zone will be monitored continuously with a MiniRae2000 photoionization detector <br />(PID) calibrated to isobutylene. Work will proceed in Level D while PID readings are between 0 and 10 parts per <br />million (ppm). In the event that breathing zone readings exceed 100 ppm, all personnel will discontinue work at <br />the location and withdraw from the work area. The appropriate vapor control measures will be implemented (e.g., <br />application of vapor suppression), the necessary emergency response authorities will be notified, and/or the work <br />area will be re-sampled until vapor levels are within acceptable levels prior to reentering the work zone. <br />Please refer to the table below for the Operational Action Levels. <br />Contaminants Action Level Action to Take <br />VOCs <br />(PID) <br />1 to 10 PPM Above background at the breathing <br />zone and sustained for 5 minutes <br />10 to 100 PPM Above background at the breathing <br />zone and sustained for 5 minutes <br />100 to 300 PPM Above background at the breathing <br />zone and sustained for 1 minute <br />>300 PPM Above background at the breathing zone <br />and sustained for 1 minute <br />Level D, continuous air monitoring <br />Upgrade to Level C, continuous air monitoring and <br />ventilate space <br />Upgrade to Level B, continuous air monitoring and <br />ventilate space, or stop work and ventilate <br />Stop work, Evacuate work zones <br />Combustible <br />Gas in Air <br />(LEL meter) <br />Less than 10% lower explosive limit (LEL) <br />Greater than 10% LEL <br />Continue with caution and air monitoring <br />(combustible gas monitoring) <br />Stop work, immediately withdrawal personnel, and <br />ventilate space with manhole blower <br />Oxygen in Air <br />(02 Meter) <br />Less than 19.5% <br />19.5 to 21.5% <br />Greater than 21.5% <br />Stop work and ventilate or upgrade to Level B <br />Level D, continue work with air monitoring <br />Stop work, immediately withdrawal personnel, and <br />evaluate <br />The PID will be calibrated daily by Partner personnel prior to use. Calibration will be performed in accordance with <br />the manufacturer specifications and recorded in a log book kept with the instrument. Ambient breathing space <br />measurements should be collected every 15 minutes. <br />Partner Site-Specific Health and Safety Plan Page 3 <br />Version 1.02 <br /> June 28, 2017
The URL can be used to link to this page
Your browser does not support the video tag.