My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
CORRESPONDENCE_2012-2014
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARNEY
>
14750
>
4400 - Solid Waste Program
>
PR0440007
>
CORRESPONDENCE_2012-2014
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/28/2025 2:23:38 PM
Creation date
6/1/2021 2:36:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4400 - Solid Waste Program
File Section
CORRESPONDENCE
FileName_PostFix
2012-2014
RECORD_ID
PR0440007
PE
4434 - LANDFILL DISPOSAL SITE - POST CLOSURE
FACILITY_ID
FA0000595
FACILITY_NAME
HARNEY LANE LANDFILL
STREET_NUMBER
14750
Direction
E
STREET_NAME
HARNEY
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06503006
CURRENT_STATUS
Active, billable
SITE_LOCATION
14750 E HARNEY LN
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\cfield
Supplemental fields
Site Address
14750 E HARNEY LN LODI 95240
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
227
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 1 of 1 <br />Natalia Subbotnikova <br />From: Robert McClellon [EH] <br />Sent: Tuesday, February 07, 2012 8:09 AM <br />To: 'Michael Carroll' <br />Cc: Natalia Subbotnikova [EH] <br />Subject: Gas Probe Modifications <br />Mike here are comments from Calrecycle staff: <br />Hello Natalia: Thank you for forwarding the proposed revision to County landfills gas compliance wells. We do <br />understand the Operator would like to reduce their purge time by inserting polyethylene tubes inside the existing <br />PVC pipes. Based on Calrecycle's landfill gas monitoring procedures, we have recommended against purging <br />the gas probes and have recommended readings once steady state has been achieved. Purging might actually <br />defeat the purpose of true gas monitoring since by purging, gas that might have had the potential to migrate and <br />accumulate within the probes will be purged. Our experience with polyethylene tubing is that they become brittle <br />and break easily and there may not be a way to tell the condition of such plastic tubing once installed within the <br />PVC. However, if the operator wants to install the plastic tubing, they should provide assurance that installing the <br />plastic tubing will not defeat the purpose of gas monitoring and that it will not compromise the integrity of <br />monitoring. <br />Mike please address the comments so that we can get back to Calrecycle. Thanks Robert <br />-)1-7/1012 <br />
The URL can be used to link to this page
Your browser does not support the video tag.