My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LODI
>
2500
>
2300 - Underground Storage Tank Program
>
PR0231356
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2022 11:24:20 AM
Creation date
6/2/2021 11:32:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231356
PE
2361
FACILITY_ID
FA0003815
FACILITY_NAME
TESORO (SPEEDWAY) 68154
STREET_NUMBER
2500
Direction
W
STREET_NAME
LODI
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
02740006
CURRENT_STATUS
01
SITE_LOCATION
2500 W LODI AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
128
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
U S T <br />M S C F <br />Page 4 of 6 <br />7. LINE LEAK DETECTOR TESTING <br />Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) <br />Simulated release rate verified: (Check all that apply.) <br />3 GPH 0.1 GPH 0.2 GPH Yes No NA <br />Has the testing apparatus been properly calibrated? <br />For emergency generator tank systems, does the LLD create an audible and visual <br />alarm when a leak is detected? <br />For mechanical LLDs, does the LLD restrict the flow through the pipe when a <br />release is detected? <br />For electronic LLDs, does the turbine automatically shut off when a release is <br />detected? <br />For electronic LLDs, does the turbine automatically shut off if any portion of the <br />monitoring system is disabled or disconnected? <br />For electronic LLDs, does the turbine automatically shut off if any portion of the <br />monitoring system malfunctions or fails a tightness test? <br />For electronic LLDs, have all accessible wiring connections been visually inspected <br />for kinks and breaks? <br />Were all items on the equipment manufacturers maintenance checklist completed? <br />Were all LLDs confirmed operational within regulatory requirements? <br />LLD ID LLD Model Lines Monitored Pass Fail <br />Describe all answers marked No or Fail and proposed remedy in Section 9. <br />List all monitoring equipment either replaced or repaired in Section 9 <br />Q1 LD2000 REGULAR <br />Q2 LD2000 PLUS <br />Q3 LD2000 PREMIUM <br />Q4 RJ 116-056-5 DIESEL
The URL can be used to link to this page
Your browser does not support the video tag.