Laserfiche WebLink
The following is an itemized list of underground storage tank violations that have not <br /> been addressed for PACIFIC SERVICE STATION as of October12 , 2021 . <br /> Open violations from August 11, 2021 inspection <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) . <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #210 - Failure to provide initial training , train every 12 months , and have a trained employee <br /> present. <br /> OBSERVATION The designated operator employee training for Primo Bonilla was not performed . <br /> REGULATION GUIDANCE: The designated operator shall train facility employees in the proper operation and <br /> maintenance of the UST system at least once every 12 months. The training shall be conducted before the <br /> individual performs the duties of a facility employees . The training shall include , but is not limited to : <br /> 1 . Operation of the UST system in a manner consistent with the facility' s best management practices <br /> 2 . Employee' s role with regard to monitoring equipment as specified in the facility' s monitoring plan <br /> 3 . Employee' s role with regard to spills and overfills as specified in the facility' s response plan <br /> 4 . Name of the contact person (s) for emergencies and monitoring equipment alarms <br /> Initial training shall also include a site-specific practical demonstration that provides both sharing information and <br /> leak detection , monitoring alarms , spills and overfills . At least <br /> evaluating knowledge for responding to emergencies , <br /> one of the facility employees present during operating hours shall have current training . <br /> CORRECTIVE ACTION: Ensure that employees have been trained by the designated operator, maintain the list on <br /> site , and submit a copy of the training records to the EHD . <br /> ❑ This violation was corrected ❑ This violation will be corrected by (date) . <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation : <br /> Violation #301 - Failure to operate UST system to prevent unauthorized releases including leaks , spills and <br /> overfills . <br /> OBSERVATION The fuel filters under the dispensers are not located to allow drips and leaks to drain back into the <br /> UDC . <br /> REGULATION GUIDANCE: The underground storage tank system shall be operated to prevent unauthorized <br /> releases , including spills and overfills . <br /> CORRECTIVE ACTION : Immediately provide approved secondary containment for the filters under permit and <br /> inspection by the EHD . <br /> Page 4 of 5 <br />