15999
>
2300 - Underground Storage Tank Program
>
PR0231945
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/30/2022 11:17:50 AM
Creation date
6/14/2021 10:56:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0231945
PE
2361
FACILITY_ID
FA0003934
FACILITY_NAME
Lawrence Livermore National Lab - Site 300
STREET_NUMBER
15999
Direction
W
STREET_NAME
CORRAL HOLLOW
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
15999 W CORRAL HOLLOW RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Monitoring System Certification Form <br /> 8. IN-TANK GAUGING TESTING <br /> PI Check this box if tank gauging is used only for inventory control. <br /> ® Check this box if NO tank gauging equipment is installed. Yes No NA <br /> Do not complete this section if either box is checked. <br /> All wiring has been: 1) visually inspected for kinks, breaks and proper entry and 17 17 <br /> termination; and 2 tested for ground faults? <br /> Were all in-tank gauging probes visually inspected for damage and residue buildup 17 17 <br /> to ensure that floats move freely, functionally tested, and confirmed operational? <br /> Was accuracy of system's product level readings tested? ® 17 <br /> Was accuracy of system's water level readings tested? 17 r] 17 <br /> Were all probes reinstalled properly? 17 <br /> Were all items on the equipment manufacturer's maintenance checklist completed? <br /> Probe ID Probe Model Tanks Monitored Pass Fail <br /> T1 846390 TFUG01 F1 r <br /> 32 846390 TFUD01 <br /> 17 17 <br /> ® 17 <br /> r El <br /> 17 <br /> 9. COMMENTS <br /> Describe all answers marked `No"or"Fail"and proposed remedy_ <br /> List all monitoring equipment either replaced or repaired. <br /> TFUG01 Unleaded is a pressure system with positive shutdown on piping sump alarms. <br /> TFUD01 Diesel is a safe suction system, verified for SJEHD during 8-5-2014 monitor cert. <br /> I <br /> FFS DC-400 sensors in UDC's provide dispenser shut off on alarms. <br /> Page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.