My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ACACIA
>
301
>
3600 - Recreational Health Program
>
PR0360117
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 3:32:57 PM
Creation date
6/15/2021 3:30:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0360117
PE
3616
FACILITY_ID
FA0000729
FACILITY_NAME
RIPON USD-RIPON HIGH SCHOOL
STREET_NUMBER
301
Direction
N
STREET_NAME
ACACIA
STREET_TYPE
AVE
City
RIPON
Zip
95366
APN
25904005
CURRENT_STATUS
01
SITE_LOCATION
301 N ACACIA AVE
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
October 26, 2011 <br />Mr. Steve Dunn <br />Vice President <br />Commercial Pool Systems, <br />252 Appalachian Dr <br />Martinez, CA 94553-6206 <br />W2�,2rsin2P2 c— <br />Inc. <br />SENT VIA EMAIL: steve@commercialpooisystems.com <br />RE: AEGIS MODEL 3030AEC USED IN ADJACENT INSTALLATIONS <br />Letter of Approval <br />Dear Steve, <br />CPS -06 <br />This letter approves the use of multiple Neptune Benson AEGIS 3030AEC suction outlet covers <br />located adjacent to each other when the specific limitations outlined below are followed. <br />1. Suction outlet covers were designed and tested to have all four edges supported. <br />When covers are used in adjacent installations, a beam is required to support the <br />adjacent edges that bridge the sump. For sump widths up to 24", a high-density <br />polyethylene beam measuring 4" wide and 2" deep may be used. This beam has a <br />moment of inertia of I=2.67 in A4 and a section modulus of 5=2.67 in A3. Using a <br />flexural strength of Fb=1400 psi, the beam has a moment capacity of M=3733 in - <br />lbs. For a simply supported beam spanning 24", the beam will support a point load <br />of 622 lbs which exceeds the required 600 Ib load. <br />2. Sumps that meet the depth criteria of 1.5 x pipe diameter may use any number of <br />covers in a linear arrangement and the total allowable flow rate is the sum of the <br />ASME A112.19.8 listed flow rate. For example, a single floor outlet is approved for <br />1432 gpm, so a pair of floor outlets is approved for 2864 gpm and three floor outlets <br />is approved for 4,296 gpm and so on. A single wall outlet is approved for 1120 gpm, <br />so a pair of wall outlets is approved for 2240 gpm and so on. In jurisdictions that <br />limit the flow-through velocity to 1.5 fps, a single outlet is approved for 600 gpm, so <br />a pair of outlets is approved for 1200 gpm and so.on. <br />3. These covers are tested and approved for use directly over pipes up to 10" diameter <br />without any sump. However, this assumes that the cover is approximately centered <br />over the pipe. If a pair of covers is placed directly over a pipe where the beam <br />crosses the pipe, the velocity through the cover will be higher in the vicinity of the <br />pipe. To equalize the flow through the perimeter of the pair of covers, it is <br />important to use a diffuser plate between the pipe and the covers. The diffuser <br />plate should be square or rectangular and measure at least 1.5 x pipe diameter in <br />the shortest dimension. For example, a 10" pipe requires a 15" square diffuser plate <br />located below the beam. The diffuser plate should be at least 1/2" thick high-density <br />polyethylene fastened with type 316 stainless steel anchors. The gap between the <br />pipe and the diffuser plate shall provide at least the same cross-sectional area as the <br />pipe itself. <br />"., . nn <br />140 Lomas Santa Fe Drive, Suite 202 Solana Beach, California 92075-12��1, 11SA't)S58. 0;1001 "Fs 8.720.9001 <br />- -- <br />
The URL can be used to link to this page
Your browser does not support the video tag.