Laserfiche WebLink
e n g i n e e r in g <br /> L H 6 & Associates, Ltd. <br /> PO Box 1205 <br /> San Luis Obispo,CA 93406 <br /> ph 805.540.5240 <br /> 4 5 4 <br /> OoFESS/o <br /> � � Z <br /> LNo. 78916 <br /> N <br /> E10 7 <br /> January 18, 2021 <br /> O O CONSULTANTS <br /> ° I 3LL <br /> 2❑ 2❑ <br /> � � g <br /> TYP. <br /> LU w <br /> a. <br /> 5 - - w 0 w p QAF <br /> I � I U) Cn <br /> L 1 REVISIONS <br /> O 5 <br /> ❑6 <br /> I L � � I I I 1 6❑ II I I I � I I <br /> SUBMITTAL DATES <br /> L J <br /> OWNER: <br /> T � <br /> REG. AGENCIES 01/18/2021 <br /> 01/18/2021 <br /> O.T.B.: <br /> PROJECT NO. <br /> 15-13-008 <br /> DRAWN BY: <br /> AFS <br /> LINE OF EXISTING—' CHECKED BY: <br /> ENTRY ROOF JRB <br /> OVERHANG ABOVE <br /> 0 4' 8' 12' <br /> ROOF PLAN <br /> SCALE: 1/4" = 1'-0" NORTH <br /> W <br /> z Z c-) <br /> c>7 <br /> LO <br /> W G)U I Z Qa <br /> LU LU < w <br /> J2O <br /> U <br /> REFERENCE NOTES <br /> LLLLI o <br /> Q m a <br /> � Q <br /> C0 <br /> 1❑ EXISTING ROOFING TO REMAIN, PATCH AND REPAIR ALL DAMAGE RESULTING W W <br /> FROM WORK UNDER THIS PERMIT APPROVAL, ENSURE A WEATHER TIGHT a <br /> ASSEMBLY. Lo Z <br /> � � <br /> 2. EXISTING REMOTE COMPRESSOR TO REMAIN. N j <br /> NEW REMOTE COMPRESSOR RIPPED 4x4 REDWOOD SLEEPERS. SPAN SLEEPERS 3. EXISTING MECHANICAL UNIT TO REMAIN. <br /> EQUIPMENT SET ON REDWOOD OVER A MINIMUM 3 EXISTING ROOF JOIST. SET <br /> SLEEPERS SLEEPERS IN ROOFING MASTIC AND FASTEN WITH 4. EXISTING ROOF AND OVERFLOW DRAINS TO REMAIN. <br /> THREE 3/8"0 LAG BOLTS MINIMUM 2" INTO 4x4 BLOCKING. <br /> PATCH AND REPAIR EXISTING CAULK AND SEAL ALONG SLEEPER BASE WITH 5. EXISTING ROOF CRICKET TO REMAIN. U_ <br /> ROOFING AS REQUIRED TO ENSURE NON-SHRINK ROOFING SEALANT FOR A WEATHERTIGHT <br /> A WEATHER-TIGHT ASSEMBLY CONDITION. 6. REMOVE EXISTING REMOTE COMPRESSOR. PATCH AND REPAIR ROOFING E <br /> ° <br /> PENETRATIONS AS REQUIRED FOR A WEATHER TIGHT FINISH o SHEET TITLE <br /> EXISTING PLYWOOD <br /> ROOF SHEATHING 7. NEW REMOTE COMPRESSOR, SEE ROOF EQUIPMENT SCHEDULE FOR ooo <br /> ADDITIONAL INFORMATION. POSITION NEW EQUIPMENT BETWEEN EXISTING <br /> ROOF TRUSSES AS INDICATED. SEE DETAIL 20/A2.1 FOR MOUNTING. <br /> Q <br /> U <br /> ----------- 8. NEW EXHAUST VENT, SEE ROOF EQUIPMENT SCHEDULE FOR ADDITIONAL o <br /> INFORMATION. 0 <br /> MIN' 9. LINE OF EXISTING ROOF TRUSSES, VERIFY SPACING IN FIELD. <br /> ROOF PLAN <br /> TYP. EXISTING PLYWOOD <br /> ROOF SHEATHING <br /> INSTALL NEW 4x4 EXISTING ROOF ROOF EQUIPMENT SCHEDULE g <br /> SOLID BLOCKING TRUSSES, VERIFY <br /> ° <br /> WITH SIMPSON HU44 SPACING IN FIELD MARK DESCRIPTION MANUFACTURER MODEL V/PH MCA MOCP WEIGHT <br /> AT EACH END <br /> C3B ICE MAKER REMOTE CONDENSER TECUMSEH AWA9490ZXTPN 208/1 15 20 320 Y <br /> C6 FROSTERS EXHAUST VENT CAPTIVE AIRE DR30HFA 120/1 4 20 45 a SHEET NO. <br /> a <br /> J <br /> E10 ICE MACHINE REMOTE CONDENSER MANITOWAC CVDT1200-261A 120/1 14.8 20 208 0 <br /> 9 All <br /> ROOF TOP COMPRESSOR MOUNTING <br /> 20 SCALE: 1"= 1'-0" <br />