Laserfiche WebLink
SAN-JOAQUIN Environmental Health Department <br /> COUNTY <br /> —"` •- Time In: 10.00 am <br /> Greotness grows here. <br /> Time Out: 11:00 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: SHERWOOD VILLAGE TOWNHOMES COA Date: 06/10/2021 <br /> Address: 42 W LANCASTER DR, STOCKTON 95207 <br /> Owner/Operator: SHERWOOD VILLAGE ASSOCIATION Telephone: <br /> Program Element: 3611 -PUBLIC POOL/SPA-PRIMARY <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #2 Pool Enclosure <br /> OBSERVATIONS:A couple of metal bars are bent. Repair(re-bent)by 1-2 weeks. <br /> CALCODE DESCRIPTION:Pool area shall be enclosed by one or more of the following:a fence,portion of a building, wall, or other <br /> approved durable enclosure.Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br /> installed no more than 2 inches above the finished grade. Holes,gaps,or openings in the enclosure shall not allow the passage of a <br /> 4-inch diameter sphere.Doors, openable windows,or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br /> 31198) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br /> perpendicular height of 5 feet and shall be constructed so that it cannot be climbed by small children.Horizontal members shall be spaced <br /> at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br /> arc. Chain link openings shall not be larger than 1314 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br /> are allowed if the enclosure was constructed prior to July 1994. (CBC 31196) <br /> #3 Safety Signs <br /> OBSERVATIONS:Write in on safety sign site address, capacity, and phone number of nearest hospital. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31208) <br /> #5 Restrooms and Showers <br /> OBSERVATIONS:Pool is currently closed. Before it reopens, clean and provide supplies. <br /> CALCODE DESCRIPTION:Pool operator shall ensure the following facilities are maintained and kept clean:showers,toilets, dressing <br /> facilities, drinking fountains,diaper-changing stations, floors, walls,partitions, doors, and lockers. Showers(except outside)shall be <br /> provided with soap in dispensers. Toilet facilities shall be provided with toilet tissue,hand soap, and paper towels or hot air blowers in <br /> permanently installed dispensers.Pool operator shall provide a minimum of one waste receptacle in each toilet facility. Wooden slats, <br /> duckboards and footbaths are prohibited. (CCR 65535, 65551)Showers and lavatories shall be provided with hot and cold water faucets. <br /> Maximum water temperature at showers and lavatories shall not exceed 110*F. (CBC 31166) <br /> FA0002169 PR0360129 SCO01 06/10/2021 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />