Laserfiche WebLink
:1Iva 07 fryl MDIVERgITEC <br /> ProTek-100TM <br /> SECTION 15.REGULATORY INFORMATION(cont.) <br /> Regulatory Status <br /> SARA 302/304:Chemicals with provided CAS numbers in this material are not subject to the reporting requirements of CERCLA. <br /> SARA 3111312:Based upon available information,this material is not classified as a health and/or physical hazard according to Section 311&312. <br /> SARA 313:This material does not contain any chemical components with known CAS numbers that exceed the De Minimis reporting levels established <br /> by SARA Title III,Section 313 and 40 CFR 372. <br /> Component Reporting Threshold <br /> State Reporting: <br /> California Proposition 65:This material is not known to contain any chemicals currently listed as carcinogens or reproductive toxins under at levels <br /> which would be subject to the proposition. <br /> Massachusetts Substances List(MSL)-Extraordinarily hazardous substances must be identified when present in material at levels greater than the <br /> state specified criterion.The criterion is-0.0001%.Hazardous Substances(MSL-HS)on the MSL must be idenfified when present in materials at <br /> levels greater than the state specified criterion.The criterion is-I%. Components with CAS numbers present in this material,at levels specified in <br /> Section 3-composition do not require reporting under the statute. <br /> State of Pennsylvania:Hazardous Substances must be identified when present in materials at levels greater than the state specified criterion.The <br /> criterion is-1%.Components with CAS numbers in this material at a level which could require reporting under the statute are:Propylene Glycoll <br /> CAS#57-55-6.Dipotassium Phosphate/CAS#7758-11-4.Special Hazardous Substances listed by the state of Pennsylvania must be identified when <br /> present in materials at levels greater than the state specified criterion.The criterion is-0.01%.Components with CAS numbers present in this material, <br /> at levels specified in Section 3-composition do not require reporting under the statute. <br /> SECTION 16.OTHER INFORMATION: <br /> Revision Summary:All Sections:New GHS Format <br /> SDS DATE REVISED:10113/2015 <br /> HMIS III Ratings: <br /> HMIS III® <br /> P 0 <br /> Personal Protection IB <br /> This information is,to the best of our knowledge and belief,accurate and reliable as of the date completed.However no representation,warranty or <br /> guarantee is made as to its accuracy,reliability or completeness.It is the user's responsibility to satisfy himself as to the completeness and suitability of <br /> such information for his own particular use.We do not accept liability for any loss or damage that may occur from the use of this information,nor do we <br /> offer any warranty against patent infringement. <br /> DiversiTech Corporation Chemical Emergency:P 800-255-3924 <br /> 6650 Sugarloaf Parkway P 678.542.3600 <br /> Duluth,GA30097 Page 5 of 5 F 678.542.3700 <br />