Laserfiche WebLink
Environmental Health Department <br />Time In: <br />10:55 am <br />10:30 am <br />Time Out: <br />Program Element: 3611 - PUBLIC POOL/SPA - PRIMARY <br />Telephone: Owner/Operator: PACIFICA STOCKTON SUITES LLC <br />Inspection Type: INSPECTION/REINSPECTION (Chargeable) <br />Address: 3240 W MARCH LN, STOCKTON 95219 <br />Date: 06/30/2021Name of Facility: RESIDENCE INN BY MARRIOT <br />Swimming Pool Official Inspection Report <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br /> #3 Safety Signs <br />OBSERVATIONS: Lack of NO LIFEGUARD ON DUTY sign. Post as soon as order is received. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br /> #7 Pool Deck <br />OBSERVATIONS: Plastic strips between concrete slabs are old and sharp. They shall be replaced or removed. If they are <br />removed, gaps shall be filled in with adequate material. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br /> #22 Skimmer Assembly <br />OBSERVATIONS: Deep skimmer lacks weir door. Install by 1 week. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate:gpm <br />pH: <br />Chlorine:ppm <br />Cyanuric acid:ppm <br />Temp:º F 80 <br />7.4 <br />6.6 <br />Combined chlorine:ppm0 <br />NOTES <br />Free chlorine level and pH levels are acceptable <br />OK to re-open pool <br />Continue to work on pending issues <br />Page 1 of 2EHD 36-01 Rev. 09/16/2020 Swimming Pool OIR <br />FA0007738 PR0507211 SC333 06/30/2021 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD