My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2024 2:25:59 PM
Creation date
7/2/2021 3:42:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2018
RECORD_ID
PR0231819
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003732
FACILITY_NAME
GAVINKO PETROLEUM*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
7700 MORELAND ST STOCKTON 95212
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification Form: Addendum for Vacuum/Pressure Interstitial Sensors <br />I. Results of Vacuum/Pressure Monitoring Equipment Testing <br />This page should be used to document testing and servicing of vacuum and pressure interstitial sensors. A copy of this <br />form must be included with the Monitoring System Certification Form, which must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of the Monitoring System Certification Form to the local <br />agency regulating UST systems within 30 days of test date. <br />J. Comments: -8-30-18 <br />If the sensor successfully detects a simulated vacuum/pressure, leak introduced in the interstitial space at the furthest point from the <br />sensor, vacuum/pressure has been demonstrated to be communicating throughout the interstice. <br />R 01/26/06 <br />UN -036A - 1/1 www.umdocs.org cv <br />Model: TLS- <br />350 <br />System Type: <br />❑ Pressure; ® Vacuum <br />Manufacturer: VEEDER ROOT <br />Sensor ID- <br />mmComponent(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ®Pass; <br />87 <br />El <br />PRODUCT LINE <br />Fail Interstitial <br />Communication Test <br />Result: ®Pass; <br />El <br />Fail <br />S-1 <br />S-2 <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ® Pass; <br />VAPOR <br />❑ Fail <br />RETURN LINE <br />Interstitial Communication Test <br />Result: ® <br />Pass; <br />❑ <br />Fail <br />S-3 <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ® Pass; <br />91 <br />❑ <br />PRODUCT LINE <br />Fail Interstitial <br />Communication Test <br />Result: ® <br />Pass; <br />❑ <br />Fail <br />S-4 <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ® Pass; <br />87191 VENT LINES <br />❑ Fail Interstitial <br />Communication Test <br />Result: ® <br />Pass; <br />❑ <br />Fail <br />S-5 <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ® Pass; <br />DIESEL <br />❑ Fail <br />PRODUCT LINE <br />Interstitial Communication Test <br />Result: ® <br />Pass; <br />❑ <br />Fail <br />S-6 <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ® Pass; <br />DIESEL <br />❑ Fail <br />VENT LINE <br />Interstitial <br />Communication Test <br />Result: ® <br />Pass; <br />❑ <br />Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; <br />❑ <br />Fail <br />Interstitial <br />Communication Test <br />Result: ❑ <br />Pass; <br />❑ <br />Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; <br />❑ <br />Fail <br />Interstitial <br />Communication Test <br />Result: ❑ <br />Pass; <br />❑ <br />Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; <br />❑ <br />Fail <br />Interstitial <br />Communication Test <br />Result: ❑ <br />Pass; <br />❑ <br />Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; <br />❑ <br />Fail <br />Interstitial <br />Communication Test <br />Result: ❑ <br />Pass; <br />❑ <br />Fail <br />How was <br />❑ Leak <br />interstitial communication verified? <br />Introduced at Far End of Interstitial Space;' ❑ Gauge; <br />® Visual Inspection; ❑ Other <br />(Describe <br />in See. <br />J, below) <br />Was vacuum/pressure restored to operating levels in all interstitial spaces? ® Yes ❑ No (If no, describe in See. <br />J, below) <br />J. Comments: -8-30-18 <br />If the sensor successfully detects a simulated vacuum/pressure, leak introduced in the interstitial space at the furthest point from the <br />sensor, vacuum/pressure has been demonstrated to be communicating throughout the interstice. <br />R 01/26/06 <br />UN -036A - 1/1 www.umdocs.org cv <br />
The URL can be used to link to this page
Your browser does not support the video tag.