Laserfiche WebLink
Appendix VI <br />ONITORING SYSTEM CERTIFICATION, <br />For Use By All Jurisdictions Within the State of CaliforniarP <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulati2018tiIns <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system ENVIRONMENTAL <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date H FAITH DEPS. RTM ENT <br />A. Generallnformation <br />Facility Name: ANGLE — 99 <br />Bldg. No.: <br />Site Address: 7700 MORELAND RD City: STOCKTON Zip: 95212 <br />Facility Contact <br />erson' ANGLE Contact Phone No.: (209) 957-5398 <br />P <br />Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 8-30-18 <br />B. Inventory of Equipment Tested/Certified <br />Chprk the nnnrnnriatp hnxps to indirste snecifir enuinment insnected/serviced: <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every <br />Tank ID: 87 <br />Tank <br />ID: N/A <br />❑ In -Tank Gauging Probe. Model: <br />N In -Tank Gauging Probe, Model: MAG 1 <br />N <br />Annular Space or Vault Sensor, <br />Model: <br />303 <br />❑ <br />Annular Space or Vault Sensor, <br />Model: <br />N <br />Piping Sump / Trench Sensor(s), <br />Model: <br />208 <br />304 <br />❑ <br />Piping Sump /Trench Sensor(s), <br />Model: <br />N <br />Fill Sump Sensor(s). <br />Model: <br />208 <br />304 <br />❑ <br />Fill Sump Sensor(s). <br />Model: <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />N <br />Electronic Line Leak Detector, <br />Model: <br />P L L <br />D <br />❑ <br />Electronic Line Leak Detector. <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor. <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor. <br />Model: <br />❑ <br />Other (specify equipment type and model in Section <br />E on Page 2). <br />❑ <br />Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: DIE <br />Tank ID: 91 <br />N <br />In -Tank Gauging Probe, <br />Model: <br />MAG <br />1 <br />® <br />In -Tank Gauging Probe, <br />Model: <br />MAG 1 <br />N <br />Annular Space or Vault Sensor, <br />Model: <br />303 <br />N <br />Annular Space or Vault Sensor, <br />Model: <br />SAME TANK <br />N <br />Piping Sump / Trench Sensor(s), <br />Model: <br />208 <br />304 <br />N <br />Piping Sump /Trench Sensor(s), <br />Model: <br />208 304 <br />N <br />Fill Sump Sensor(s), <br />Model: <br />208 <br />304 <br />N <br />Fill Sump Sensor(s), <br />Model: <br />208 304 <br />❑ <br />Mechanical Line Leak Detector. <br />Model: <br />❑ <br />Mechanical Line Leak Detector, <br />Model: <br />N <br />Electronic Line Leak Detector, <br />Model: <br />P L L <br />D <br />N <br />Electronic Line Leak Detector, <br />Model: <br />PLL D <br />❑ <br />Tank Overfill / High -Level Sensor. <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor. <br />Model: <br />❑ <br />Other (specify equipment type and model in Section <br />E on Page 2). <br />❑ <br />Other (specify equipment type and model in Section E on Page 2), <br />Dispenser ID: 1/2 <br />Dispenser ID: 314 <br />N <br />Dispenser Containment Sensor(s), <br />Model: <br />208 <br />304 <br />N <br />Dispenser Containment Sensor(s). <br />Model: <br />208 304 <br />N <br />❑ <br />Shear Valve(s). <br />Dispenser Containment Float(s) and <br />Chain(s). <br />N <br />❑ <br />Shear Valve(s). <br />Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: 516 <br />Dispenser ID: 7/8 <br />N <br />Dispenser Containment Sensor(s), <br />Model: <br />208 <br />304 <br />N <br />Dispenser Containment Sensor(s), <br />Model: <br />208 304 <br />N <br />ShearValve(s), <br />N <br />ShearVaive(s). <br />❑ <br />Dispenser Containment Float(s) and <br />Chain(s). <br />❑ <br />Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: VENT <br />Dispenser ID: <br />❑ <br />Dispenser Containment <br />❑ <br />Dispenser Containment Sensor(s), <br />Model: <br />208 <br />304 <br />Sensor(s). <br />Model: <br />❑ <br />Shear Valve(s). <br />❑ <br />Shear Valve(s). <br />❑ <br />Dispenser Containment Float(s) and <br />Chain(s). <br />❑ <br />Dispenser Containment Float(s) <br />and Chain(s). <br />tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): N System set-up ® Alarm history report <br />Technician Name (print): DAVE WINKLER <br />Certification No.: 834975 <br />Testing Company Name: AFFORDA-TEST <br />Testing Company Address: 416 2nd STREET GALT, CA 95632 <br />Signature: n j <br />License No: 04-1676 <br />Phone No. (209) 744 <br />Date of Testing/Servicing: <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />