COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4040
>
2300 - Underground Storage Tank Program
>
PR0231963
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2021 3:02:27 PM
Creation date
7/2/2021 4:24:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0231963
PE
2361
FACILITY_ID
FA0006445
FACILITY_NAME
PG&E: Stockton Service Center
STREET_NUMBER
4040
STREET_NAME
WEST
STREET_TYPE
Ln
City
Stockton
Zip
95204
APN
117-020-01
CURRENT_STATUS
01
SITE_LOCATION
4040 West Ln
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SII <br />TAI T <br />p:714156018222 www.toit.com <br />LEAK DETECTOR TESTING <br />Facility ID: PGE095 <br />Street Address: 4040 West Ln. <br />City: Stockton <br />°..431 $. ^::pOSA np:..� n4G1�81"', �.^, °2��5 <br />Test Date: 09/20/2019 <br />Client Name: Pacific Gas and Electric Compa <br />Technician: Craig Feezell <br />ICC #: 8374133 <br />Zip Code /State: 95204 / CA Manufacturer Cert #: A23508 <br />Test Information <br />❑ Check If Action Items) Are Present <br />This letter certifies that the annual leak detector tests were performed at the above referenced facility <br />according to the equipment manufacturers procedures and limitations and the results as listed are to my <br />knowledge true and correct. The leak detector test pass/fail is determined using a low flow threshold trip <br />rate of 3 gph at 10 PSI. <br />Technician Signature: <br />Date: 09/20/2019 <br />CA li[N 588098 ! AZ IieN 095984 ! NV IiCN 00496b6 1 TX IiGN CR0000041 <br />Unleaded <br />Diesel <br />Product <br />Veeder-Root <br />Veeder-Root <br />Manufacturer <br />PLLD <br />PLLD <br />Model <br />New Leak Detector <br />No <br />No <br />Yes/No <br />Serial Number <br />119293 <br />119295 <br />Electronic LD <br />Yes <br />Yes <br />Yes/No <br />Calibrated Test Leak <br />Rate: (189 mil/min <br />Yes <br />Yes <br />10 PSI) (Yes/No) <br />Check Valve Holding <br />22.242 <br />21.703 <br />PSI <br />Resiliency <br />n/a <br />n/a <br />(Bleed Back MIL) <br />Slow Flow <br />n/a <br />n/a <br />Meterin PSI / N/A <br />Turbine Shut Down <br />Electronic LD <br />Yes <br />Yes <br />Yes/No/NA <br />Slow Flow At Nozzle <br />n/a <br />n/a <br />(Yes/No/NA) <br />Opening Time <br />n/a <br />n/a <br />(Seconds) <br />Pass/Fail <br />Pass <br />Pass <br />❑ Check If Action Items) Are Present <br />This letter certifies that the annual leak detector tests were performed at the above referenced facility <br />according to the equipment manufacturers procedures and limitations and the results as listed are to my <br />knowledge true and correct. The leak detector test pass/fail is determined using a low flow threshold trip <br />rate of 3 gph at 10 PSI. <br />Technician Signature: <br />Date: 09/20/2019 <br />CA li[N 588098 ! AZ IieN 095984 ! NV IiCN 00496b6 1 TX IiGN CR0000041 <br />