COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRESNO
>
1524
>
2300 - Underground Storage Tank Program
>
PR0506545
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2022 11:36:12 AM
Creation date
7/7/2021 9:11:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0506545
PE
2361
FACILITY_ID
FA0007491
FACILITY_NAME
VALLEY PACIFIC FRESNO AVE CARDLOCK
STREET_NUMBER
1524
STREET_NAME
FRESNO
STREET_TYPE
AVE
City
STOCKTON
Zip
95206
APN
16337025
CURRENT_STATUS
01
SITE_LOCATION
1524 FRESNO AVE
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CGRS UST Spill Bucket <br /> SOLUTIONS DEUVEFIED • <br /> Integrity Testing Form <br /> Underground Storage Tanks ( UST) Program <br /> Instructions on Page 3 <br /> Purpose : This procedure is to test the leak integrity of single - and double -walled spill buckets . See reverse side for <br /> basic hydrostatic testing instructions . Consult PEI/RP1200 , Section 6 . 2 for hydrostatic test method , Section 6 . 3 for <br /> single -walled vacuum test method , and Section 6 .4 for double -walled vacuum test method . <br /> Testing Information <br /> 1 . Tank number T1 :Diesel <br /> 2. Product stored Diesel <br /> 3. Spill bucket capacity 5 Gallons <br /> 4, Manufacturer OPW <br /> E Single-walled ❑ Single-walled ❑ Single-walled ❑ Single -walled ❑ Single-walled ❑ Single-walled <br /> 5. Construction ❑ Double-walled ❑ Double-walled ❑ Double-walled ❑ Double-walled ❑ Double-walled ❑ Double-walled <br /> ❑ Hydrostatic ❑ Hydrostatic ❑ Hydrostatic ❑ Hydrostatic ❑ Hydrostatic ❑ Hydrostatic <br /> ❑ Vacuum ❑ Vacuum ❑ Vacuum ❑ Vacuum ❑ Vacuum ❑ Vacuum <br /> ❑ Single-walled ❑ Single -walled ❑ Single-walled ❑ Single-walled ❑ Single-walled ❑ Single-walled <br /> 6. Test pe ❑ Double-walled ❑ Double-walled ❑ Double-walled ❑ Double-walled ❑ Double-walled ❑ Double-walled <br /> 9 Product ❑ Product ❑ Product ❑ Product ❑ Product ❑ Product <br /> 7 . Spill bucket type ❑ Vapor ❑ Vapor ❑ Vapor ❑ Vapor ❑ Vapor ❑ Vapor <br /> 8 . Liquid and debris <br /> removed from spill <br /> bucket:* © Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No ❑ Yes ❑ No <br /> 9. Visual inspection <br /> (No cracks, loose parts or <br /> separation of the bucket <br /> from the fill pipe.)? J1 Pass [] Fall ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass ❑ Fail <br /> 10. Tank riser cap included in <br /> test? © Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br /> 11 . Is drain valve included in <br /> test? E Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA ❑ Yes ❑ No ❑ NA <br /> 12. Starting level 13.00" <br /> 13. Test start time 11 :40am <br /> 14. Ending level 13.00" <br /> 15. Test end time 12:40pm <br /> 16. Test period 1 hour <br /> 17. Level Chan e 0 <br /> Test results : .❑ Pass ❑ Fail ❑ Pass ❑ Fail [] Pass ❑ Fail ❑ Pass ❑ Fail ❑ Pass [] Fall ❑ Pass ❑ Fail <br /> Pass/fail criteria: Must pass visual inspection. Hydrostatic: Water level drop of less than 1/8 inch; Vacuum single-walled only; <br /> Maintain at least 26 inches water column; Vacuum double-walled; maintain at least 12 inches water column. <br /> Comments : <br /> * All liquids and debris must be disposed of properly. <br /> Testing company CILJI-1S Garrett Warren <br /> name : �% = Testers name : <br /> Date : 01 /03/2019 Tester' s signature : �o <br /> GPH = Gallons per hour, Y = Yes, N = No, NA = Not applicable, VPH = Vacuum/PressureMydrostatic, ID = Identification <br />
The URL can be used to link to this page
Your browser does not support the video tag.