June 9, 2021 <br />Lab ID : STK2137320 <br />San Joaquin Co. Environmental Health Dep Customer : 3-17919 <br />Quality Control - Inorganic <br />Constituent Method Date/ID Type Units Conc. QC Data DQO Note <br />Wet Chem <br />Nitrate 300.0 (VI 2143484-002) MSD mg/L 40.00 88.0% 85-119 <br />MSRPD mg/L 10.00 1.0% <19 <br />300.0 05/25/21:207838MCA ICB mg/L 0.000 0.5 <br />ICV mg/L 20.00 101% 90-110 <br />CCB mg/L 0.000 0.5 <br />CCV mg/L 20.00 102 % 90-110 <br />Nitrate + Nitrite as N 300.0 05/25/21:205821MCA Blank mg/L ND <0.1 <br />Nitrate Nitrogen 300.0 05/25/21:205821MCA Blank mg/L ND <0.1 <br />Nitrite 300.0 05/25/21:205821MCA Blank mg/L ND <0.5 <br />LCS mg/L 15.00 101% 90-110 <br />MS mg/L 30.00 104% 74-126 <br />(CH 2173257-001) MSD mg/L 30.00 104% 74-126 <br />MSRPD mg/L 10.00 0.3% <0 <br />MS mg/L 30.00 103 % 74-126 <br />(VI 2143484-002) MSD mg/L 30.00 101 % 74-126 <br />MSRPD mg/L 10.00 2.1% <0 <br />300.0 05/25/21:207838MCA ICB mg/L 0.000 0.5 <br />ICV mg/L 15.00 101% 90-110 <br />CCB mg/L 0.000 0.5 <br />CCV mg/L 15.00 102% 90-110 <br />Nitrite Nitrogen 300.0 05/25/21:205821MCA Blank mg/L ND <0.2 <br />Sulfate 300.0 05/25/21:205821MCA Blank mg/L ND <0.5 <br />LCS mg/L 50.00 101% 90-110 <br />MS mg/L 100.0 93.3 % 82-124 <br />(CH 2173257-001) MSD mg/L 100.0 93.9% 82-124 <br />MSRPD mg/L 10.00 0.4% <3 <br />MS mg/L 100.0 98.2 % 82-124 <br />(V12143484-002) MSD mg/L 100.0 96.6% 82-124 <br />MSRPD mgL 10.00 1.2% <3 <br />300.0 05/25/21:207838MCA ICB mg/L 0.171 0.5 <br />ICV mg/L 50.00 101% 90-110 <br />CCB mg/L 0.171 0.5 <br />CCV mg/L 50.00 102% 90-110 <br />MBAS 5540C 05/26/21 :208187jba CCB mg/L -0.0351 0.25 <br />CCV mg/L 1.000 94.5 % 90-110 <br />CCB mg/L -0.0226 0.25 <br />CCV mg/L 1.000 94.9% 90-110 <br />MBAS Extraction 5540C 05/25/21:206063jba Blank mg/L ND <0.1 <br />LCS mg/L 0.5000 94.5 % 86-114 <br />BS mg/L 0.5000 95.1% 86-114 <br />BSD mg/L 0.5000 93.8 % 86-114 <br />BSRPD mg/L 0.5000 0.0063 <0.1 <br />Definition <br />ICV : Initial Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br />ICB : Initial Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br />CCV : Continuing Calibration Verification - Analyzed to verify the instrument calibration is within criteria. <br />CCB : Continuing Calibration Blank - Analyzed to verify the instrument baseline is within criteria. <br />Blank : Method Blank - Prepared to verify that the preparation process is not contributing contamination to the samples. <br />LCS : Laboratory Control Standard/Sample - Prepared to verify that the preparation process is not affecting analyte recovery. <br />MS : Matrix Spikes - A random sample is spiked with a known amount of analyte. The recoveries are an indication of how that sample <br />matrix affects analyte recovery. <br />MSD : Matrix Spike Duplicate of MS/MSD pair - A random sample duplicate is spiked with a known amount of analyte. The recoveries <br />are an indication of how that sample matrix affects analyte recovery. <br />BS : Blank Spikes - A blank is spiked with a known amount of analyte. It is prepared to verify that the preparation process is not <br />affecting analyte recovery. <br />Page 8 of 9