Laserfiche WebLink
r I Environmental Health Department <br /> SANJOAQU <br /> CUBIT <br /> Greotrr$55 grows here Time In: 10.45 am <br /> Time Out: 11:00 am <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: WESTPOINTE APARTMENTS NE SPA Date: 07/28/2021 <br /> Address: 6465 N WEST LN, STOCKTON 95210 <br /> Owner/Operator: PATMON COMPANY INC Telephone: (209)951-4391 <br /> Program Element: 3612-PUBLIC POOL/SPA-ADDITIONAL <br /> Inspection Type: ROUTINE INSPECTION -Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #10 Disinfectant Residual MAJOR <br /> OBSERVATIONS:Free residual chlorine was above 10 ppm. Maintain chlorine levels between 3.0 ppm and 10 ppm. <br /> CALCODE DESCRIPTION:Public pools, when open or in use,shall be disinfected continuously by approved chemicals and shall maintain <br /> the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br /> or 2.0 ppm bromine. Spas, wading pools,and spray grounds shall maintain the following concentrations:3.0 ppm to 10.0 ppm free <br /> chlorine or 4.0 ppm bromine. (CCR 65529) <br /> #37 Electrical Hazards MAJOR <br /> OBSERVATIONS:GFCI is not operational. Install operating GFCI. <br /> CALCODE DESCRIPTION:Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply with <br /> California Electrical Code. (CEC 680.4)Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a ground <br /> fault circuit interrupter. (CBC 31608) <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:Spa light is not operational. Replace/repair light. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31156) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 70 gpm Chlorine: Above 10 ppm Temp: ° F <br /> Cyanuric acid: 100 ppm pH: 7.4 Combined chlorine: ppm <br /> NOTES <br /> Influent: 19 psi <br /> Effluent: 14 psi <br /> Spa closed. Contact for re inspection. <br /> FA0002425 PR0360593 SCO01 07/28/2021 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />