Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
1233
>
2300 - Underground Storage Tank Program
>
PR0547072
>
INSTALL_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2023 4:46:46 PM
Creation date
8/5/2021 11:01:30 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2021
RECORD_ID
PR0547072
PE
2351
FACILITY_ID
FA0026688
FACILITY_NAME
7-ELEVEN STORE # 41342
STREET_NUMBER
1233
Direction
E
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95205
CURRENT_STATUS
03
SITE_LOCATION
1233 E DR MARTIN LUTHER KING JR BLVD
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
110
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL NOTES <br /> co <br /> I— <br /> z <br /> Lu <br /> 1 ALL VACUUM TUBING MUST BE VEEDER ROOT <br /> APPROVED VACUUM TUBING. <br /> O <br /> 2 C U � <br /> 2 AN EXTERNAL SIPHON CHECK VALVE (VEEDERz <br /> LLJ <br /> ROOT#3188-241-5) MUST BE USED WHEN MAKING W_ <br /> A VACUUM SOURCE SENSORS AND THE SIPHON US > <br /> PORT CARTRIDGE FOR ALL TURBINES. � L O <br /> 3 ALL PENETRATIONS THROUGH TANKS SUMPS, W >- <br /> STP UDC SUMPS AND VENT SUMPS TO BE MADE BY A W ~ <br /> WITH 1-1/2"X 1/4" 35 STP WITH 1-1/2"X 1/4" 35 QUALIFIED CONTRACTOR. N No <br /> BRASS BUSHING AND BRASS BUSHING AND <br /> 1/4" BRASS BARB 31 4 ALL CONTAINMENT SUMPS TO BE INSTALLED PER ATG 3-ZONE 1/4" BRASS BARB ATG 31 3-ZONE THE MANUFACTURERS INSTALLATION C) N N <br /> FITTING BY GC ° VACUUM KIT FITTING BY GC ° VACUUM KIT INSTRUCTIONS. o <br /> _ N <br /> STP POWER CONDUIT SENSOR CONDUIT STP POWER CONDUIT 5 ALL CONDUIT PENETRATIONS AND J-BOXES TO SENSOR CONDUIT BE INSTALLED ABOVE FUEL LINE PENETRATIONS. as <br /> ° ° ° ° 1 2 ° ° ° 6 CONTRACTOR SHALL POSITION LIQUID ONLY Proto 11-05-18 <br /> PRODUCT PIPING VACUUM PIPING PRODUCT PIPING VACUUM PIPING SUMP SENSORS AT SUMP LOW POINT ON SIDE <br /> ° ° ° ° ° ° 010 ° CLOSEST TO PRODUCT PIPING. <br /> 03 02 02 03 03 02 02 03 <br /> O KEY NOTES co <br /> NOTE: NOTE: LO <br /> LIQUID ONLY SENSOR VACUUM KIT TO BE MOUNTED TO IQUID ONLY SENSOR VACUUM KIT TO BE MOUNTED TO ti 0 <br /> ATG RISER. ATG RISER. U) � <br /> REF SHEET G12.2 FOR ADDITIONAL 1❑ ELECTRICAL CONDUIT(S)TO ENTER SUMP 2" MIN Q Q <br /> REF SHEET G12.2 FOR ADDITIONAL ABOVE HIGHEST PRODUCT PENETRATION. X N > <br /> SUMP SECTION (FOR VACUUM ZONES INFORMATION SUMP SECTION (FOR VACUUM ZONES INFORMATION r ,' W W (n <br /> VACUUM ONLY AND DETAILS. VACUUM ONLY AND DETAILS. �2 LOCATE ELECTRICAL JUNCTION BOX IN UPWARD U M p J I.-_ <br /> POSITION AT HIGHEST LOCATION IN SUMP RISER Z z O Lo <br /> MAINTAIN 8"TO 10"CLR Q <br /> FOR EASY ACCESS FROM ABOVE. > m � Lu <br /> FROM TOP OF MANHOLE COVER MAINTAIN 8"TO 10" CLR ^ 0� Q 0 �- <br /> 19 TO TOP OF WT COVER 19 FROM TOP OF MANHOLE COVER ❑3 SUMP SENSOR TO REST AT LOWEST POINT OF Z — Y U D <br /> 4 WATERTIGHT COVER WITH TO TOP OF WT COVER 0 J - 0- O <br /> SUMP ENCLOSURE ON PRODUCT PIPING SIDE OF W Z Z <br /> OBSERVATION PORT 4 WATERTIGHT COVER WITH SUMP. TANK CONTRACTOR TO SUPPLY ALL > a0 LL] O > LLJ <br /> 20 20 OBSERVATION PORT BRACKETS AND CLAMPS FOR 2-POINT MOUNTING 0 � U) J <br /> CONCRETE TANK SLAB u _ ALIGN PORT WITH ATG CONCRETE TANK SLAB ° J >- w � U Y z <br /> ALIGN PORT WITH ATG OF THE 2" FRP SLEEVE. <br /> L1J O Y � U <br /> TRIM MH SKIRT TO MAINTAIN 2"TO 4" a _ <br /> 01 01 a a a � TRIM MH SKIRT TO MAINTAIN U O <br /> BETWEEN SUMP SECURE FOAM PIPE 4 SET MANHOLE COVERS 1"ABOVE THE FINISH LL] Df J O � Q (n <br /> INSULATION TO BOTTOM OF MH SKIRT. 10 d 2"TO 4" BETWEEN SUMP GRADE AND SLOPE CONCRETE AWAY FROM I LU W c U) <br /> SECURE FOAM PIPE INSULATION � m <br /> ADD INSULATION AS REQUIRED TO ° TO BOTTOM OF MH SKIRT MANWAY COVERS AT 2% GRADE. U (W <br /> 2 ° PREVENT CONCRETE FROM BEING POURED E__ ° <br /> EXPLOSION PROOF ON SEALED MANHOLE EXPLOSION PROOF 2 EXPLOSION PROOF J-BOX �5 POSITION BALL VALVE FOR UNOBSTRUCTED USE = N <br /> J-BOX TYP (POWER) J-BOX TYP (POWER) (FOR SENSORS) OF SHUT-OFF HANDLE. <br /> 2 EXPLOSION PROOF J-BOX O <br /> ELEC SEAL-OFFp <br /> -� (FOR SENSORS) ELEC SEAL-OFF— STP POWER CONDUITS MUST BE RUN IN N <br /> 5 30 m m E m m M <br /> 2"SCHED 40 GALV PIPE FITTINGS SEPARATE RACEWAY. ENTIRE WIRING RUN MUST <br /> ELEC SEAL-OFF CONDUIT AND LBY'S TO 6 FOR REGULAR AND PREMIUM BE IN RIGID PVC COATED GALVANIZED STEEL <br /> CONDUIT AND LBY'S TO 6 STP POWER CONNECTION BY GC CONDUIT. USE ONLY ROB ROY CONDUIT TYPES <br /> STP POWER CONNECTION -----E]CONDUIT FROM ANNULAR SPACE CONDUIT FROM ELEC ROOM 6 ELEC SEAL-OFF "PERMA-COAT", "PLASTI-BOND"OR"KORKAP", NO <br /> CONDUIT FROM ELEC 6 MANHOLE FOR SENSORS FOR STP POWER <br /> PVC OR RNC CONDUIT ALLOWED. <br /> ROOM FOR STP POWER 1 7 6 1 7 CONDUIT FROM ANNULAR SPACE <br /> FUEL PLUMBING TREE MANHOLE FOR SENSORS ❑7 USE ONLY ROB ROY CONDUIT TYPES <br /> 1 ° ° ° ° ° ° XERXES DW SUMP SUPPLIED— ° ° ° ° ° "PERMA-COAT", "PLASTI-BOND"OR"KORKAP" <br /> REF 5-G4.1 1 7 <br /> w/TANKS (TYP) ELECTRICAL CONDUITS AT FIBERGLASS TANK <br /> QO ° ° ° ° 06 ° ° ° ° FUEL PIPING TREE SUMPS OR WHERE BRAVO F-17-RR OR F-10-RR <br /> 2" SCHED 40 BLACK IRON ° G0 Qp ° REF 5-G4.1 ENTRY FITTINGS ARE CALLED OUT. <br /> PIPE FITTINGS FOR 2"SCHED 40 GALVANIZED 06 <br /> DIESEL BY GC SUMP SENSOR BRACKET PIPE FITTINGS FOR REGULAR W <br /> U-BOLTED TO ATG RISER (2 LOC) AND PREMIUM BY GC GO <br /> 2" FRP X 33" LONG MIN 03 PIPE CLAMPS, SENSOR BRACKETS 2" FRP X 33" LONG MIN 03 SUMP SENSOR BRACKET W <br /> (BEYOND) FOR SUMP SENSOR AND U-BOLTS BY GC (BEYOND) FOR SUMP SENSOR <br /> U-BOLTED TO ATG RISER (2 LOC) <br /> HOUSING 1" CLR FROM TANK HOUSING 1" CLR FROM TANK PIPE CLAMPS, SENSOR BRACKETS <br /> 05 05 AND U-BOLTS BY GC <br /> 3 3 ZcD <br /> z <br /> 0 <br /> Lu <br /> 58 58 z <br /> 16 55 w N <br /> 11 10 <br /> W � o <br /> a <br /> X � <br /> H 0 <br /> STRIKE PLATES STRIKE PLATES z a <br /> BY TANK MFR BY TANK MFRJ <br /> ui W o 3 <br /> Z o 3 <br /> Z O0 <br /> W <br /> O J JM <br /> W U <br /> FW V H N <br /> tw. y J <br /> r H <br /> SECTION SECTION _ <br /> U <br /> Ono w <br /> ROTATE VIEW AS REQUIRED FOR FIELD CONDITION NOTE: ROTATE VIEW AS REQUIRED FOR FIELD CONDITION NOTE: Q VACUUM KIT(NOT SHOWN) VACUUM KIT(NOT SHOWN) <br /> TO BE MOUNTED TO ATG RISER. <br /> ELECTRICAL PENETRATIONS INTO SUMP ARE SHOWN FOR TO BE MOUNTED TO ATG RISER. ELECTRICAL PENETRATIONS INTO SUMP ARE SHOWN FOR <br /> REFERENCE ONLY-COORDINATE LOCATIONS WITH REF SHEET G12.2 REFERENCE ONLY-COORDINATE LOCATIONS WITH REF SHEET G12.2 M Q O Q = <br /> FOR VACUUM ZONES AND DETAILS. � W N � J <br /> 03 SHEET G9 AND FIELD CONDITIONS FOR VACUUM ZONES AND DETAILS. TYP 03 SHEET G9 AND FIELD CONDITIONS CVP 00 Y � <br /> 02 TYP 02 Q Z O <br /> 11 TYP 11 (1) <br /> 06 MINIMUM 4'-0" STRAIGHT RUN OF TYP 06 MINIMUM 4'-0" STRAIGHT RUN OF ¢ m _0 <br /> 03 PIPING PRIOR TO FIRST CHANGE 03 PIPING PRIOR TO FIRST CHANGE N <br /> OF DIRECTION FITTING TYP OF DIRECTION FITTING U <br /> 16 <br /> ° ° 03 16 ° ° 03 (� N <br /> 2 FRP X 33 LONG MIN TYP ° ° O U L <br /> 2 FRP X 33 LONG MIN <br /> GO ° ° (BEYOND) FOR SUMP SENSOR GC ° ° (BEYOND) FOR SUMP SENSOR (n Q Q (� <br /> HOUSING 1" CLR FROM TANK HOUSING 1" CLR FROM TANK <br /> 11 05 10 05 _0 o c �= <br /> FUEL PLUMBING TREE 3 FUEL PIPING TREE 3 _c_- M U) M N c o: Q o <br /> (BELOW DISCHARGE) o ° ° S1 DESICCANT BAG W/HANGER (2) (BELOW DISCHARGE) ° ° ° S DESICCANT BAG W/HANGER(2) a�vi_° o Q- w I- (� <br /> REF 5-G4.1 o PER SUMP REF 5-G4.1 o PER SUMP - oL.r o c o � o o c <br /> 2 E <br /> CONDUIT AND LBY'S TO 6 ° o 6 SUMP SENSOR BRACKET CONDUIT AND LBY'S TO ° o SUMP SENSOR BRACKET m .� c o L 'U) <br /> a' STP POWER CONNECTION ° U-BOLTED TO ATG RISER (2 LOC) STP POWER CONNECTION ° U-BOLTED TO ATG RISER (2 LOC) a X m <br /> ❑ ° PIPE CLAMPS, SENSOR BRACKETS ❑ o Q o a m �Lo c c >. <br /> o EXPLOSION PROOF 2 AND U-BOLTS BY GC EXPLOSION PROOF 2 AND U BO TS BY G OR BRACKETS _0 O C A m o 0 <br /> "' J-BOX(FOR STP POWER) J-BOX(FOR STP POWER) °° ° c ) cn Q � `� E <br /> N 7 1 S12 7 1 S12 c°`~ a2 ��`_ a) <br /> E °° ° E E ° v 0-f- o cn v� <br /> o cnw� <br /> ° 2 EP J-BOX TYP (SENSORS) ° 2 EP J-BOX TYP (SENSORS) o m � m Q m a o <br /> CONDUIT FROM ELEC 6 0 ° ° ° S1 1 7 CONDUIT FROM ELEC ROOM 6 ° ° ° ° 12 1 7 in 0 p uQi p="�j L <br /> cli ROOM FOR STP POWER 7 CONDUIT FROM ANNULAR SPACE FOR STP POWER 7 CONDUIT FROM ANNULAR SPACEItl o <br /> 0 <br /> MANHOLE FOR SENSORS MANHOLE FOR SENSORS <br /> Q�OFESS/ <br /> o XERXES 42" EIGHT SIDED DW z z LIJ <br /> SUMP-SUPPLIED w/TANK(TYP) Q XERXES 42" EIGHT SIDED DW < 0 <br /> W 35558 m <br /> SUMP- SUPPLIED w/TANK(TYP) J, N <br /> ca_ CHANIGP <br /> T�OF CA1.�FOQL <br /> N REF SECTION PLAN REF SECTION PLAN <br /> 03/23/21 <br /> SHEET: <br /> M <br /> m <br /> D ESEl STP SUMP DETA IS REGULAR AND PREMIUM STP SUMP DETAILS G4 . 0 <br /> z <br /> LLJ 3/4 <br /> cz <br /> FUELING - USA CA <br />