Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sagov.org/ehd <br /> ABOVEGROUND PETROLEUM STORAGE ACT (APSA) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility 0-1/0wens Brockway Addres14700 West Schulte Road, Tracy InspDateection May 26, 2011 <br /> Name: s: <br /> VIOLATIONS <br /> # V R Code Section HSC=CA Health and SafetyCode;CFR=Code of Federal Regulations;v=Violation,RV=Repeat violation <br /> Specific requirements of HSC 25270.4.5(a)are identified as CFR code sections beginning with 112 <br /> Failed to:test each aboveground container for integrity on a regular schedule or when repairs were made, <br /> 48 CFR 112.8(c)(6) inspect containers and container supports; or keep records of inspections and tests, or provide <br /> equivalence as allowed by CFR 1112.7(a)(2) <br /> 49 CFR 112.8(c)(7) Failed to provide effective leakage control through defective internal heating coils,or provide equivalence <br /> as allowed by CFR 11 2.7a 2 <br /> 50 CFR 112.8(c)(8) Failed to install and regularly test approved liquid level sensing devices, or provide equivalence as allowed <br /> by CFR 112.7a 2 <br /> 51 CFR 112.8(c)(9) Failed to observe effluent treatment facility frequently enough to detect system upsets that could cause a <br /> discharge,or provide equivalence as allowed by CFR 11 2.7a 2 <br /> 52 CFR 112.8(c)(10) Failed to promptly correct visible discharges and/or remove accumulations of oil in diked areas,or provide <br /> equivalence as allowed by CFR 112.7(a)(2) <br /> 53 CFR 1 12.8(c)(11) Failed to locate portable containers to prevent discharge or provide sufficient secondary containment <br /> capacity that will hold the volume of the largest container plus sufficient freeboard to contain precipitation <br /> Failed to provide buried piping with a protective wrapping and coating and cathodic protection and/or <br /> 54 CFR 112.8(d)(1) inspect buried piping for corrosion damage when exposed, or provide equivalence as allowed by CFR <br /> 112.7 a 2 <br /> 55 CFR 112.8(d)(2) Failed to cap or blank-flange terminal connection at transfer point and mark its origin when piping is not in <br /> service or in standby service for an extended time,or provide equivalence as allowed by CFR 112.7(a)(2) <br /> 56 CFR 112.8(d)(3) Failed to design pipe supports to minimize abrasion and corrosion and to allow for expansion and <br /> contraction, or provide equivalence as allowed by CFR 11 2.7a 2 <br /> 57 CFR 112.8(d)(4) Failed to regularly inspect aboveground valves,piping, and appurtenances, or provide equivalence as <br /> allowed by CFR 112.7(a)(2) <br /> 58 CFR 112.8(d)(4) Failed to conduct integrity and leak test for buried piping at time of installation,modification,construction, <br /> relocation, or replacement, or provide equivalence as allowed by CFR 112.7(a)(2) <br /> r59 CFR 112.8(d)(5) Failed to provide adequate warnings to vehicles entering facility to protect aboveground piping and otheroil transfer o erations,or rovide e uivalence as allowed b CFR 112.7(a)2 Other: See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> Inventory, gallons - contents, size container, location (000 IeLa fit' P—L 4-q,v1k/ <br /> 1750 - salvage used oil, 60h*60w*1201, A/B Basement vm <br /> 1000 - diesel emergency generator 44d*121 <br /> 180 - diesel fire pump 30d*51 <br /> 180*2 - diesel fire pump, 35d*431 (empty), Bldg D <br /> 450 - salvage used oil, 3h*2w*101, C Basement <br /> 140 - diesel emergency generator, furance A <br /> 195*2 - diesel emergency generator, furance B, C <br /> 100, 200 - Biosol tank, biosol Mixing Rm Furance Bldg <br /> 55 - Biosol drum, biosol Mixing Rm Furance Bldg <br /> 96*3 - Com pressor-Ingeroll Rand C-40 #1, C-40 #2, C-55 Compressor Rm <br /> 150 - Compressor-Ingeroll Rand C-70, C-90 Compressor Rm <br /> 65 - SSR screw compressor <br /> 105 - hydraulic cardboard baler warehouse <br /> 3000 - cullet water skimmer pond, oil-water separator <br /> 6600 - lube, oil, torque, transmission oil, Blue Barn <br /> _1833_= estimated total. *(inventory not including transformers) <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY <br /> RATE.THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspect Phoneaceived By: Title, <br /> 7 ' <br /> (209)468-8257 <br /> EHD 28-02 Rev 2/19/10 Page 3 APSA INSPECTION REPORT <br />