Laserfiche WebLink
14700 W Schulte Rd, Tracy, CA Record ID PRO516327 <br /> 4-14-2016 PHOTO#6 <br /> SourceTable 2 continued <br /> Volume Released Spill Rate - <br /> Direction of Flow Fail-Safe Feature <br /> Salvage/Used OilUp to Several Leaking Pipe or Valve <br /> _ <br /> AST Gallons Gradual Towards oil/water Located within building. Drains in the areas <br /> Diesel Fuel AST UP to Several separator flow back to oilhvater se arators <br /> Gallons Gradual Towards low spot <br /> Diesel Fuel AST Fire p within containment AST is located within a containment berm <br /> to <br /> U Several Towards low spot <br /> Pum Gallons Gradual p <br /> Diesel Fuel AST within containment AST is located within a containment berm <br /> Building D Fire Up to Several Towards Storm water Onsite retention. General secondar, <br /> Pum Gallons Gradual Pond#7 containment is provided by the design of the " <br /> DieselFuel AST area.. <br /> Up to Several Gradual Towards los spot in Onsite retention. General secondary <br /> G <br /> Generator Tanks Gallons <br /> area or building floor. containment is provided by the design of the <br /> Biosol Mixing Up to Several area.. <br /> Tanks Gradual Towards low spot in Located within building. Drains in the areas <br /> Gallons Biosol MixingRoorn now back to oil/water se arators _ <br /> Tank Truck Leak or Failure <br /> Salvage/Used Oil Gradual to Towards oil/water Located within buildings. Drains in the areas <br /> AST 11P to 1,000 gallons <br /> Instantaneous se ara--tor flow back to oil/water separator t <br /> Diesel Fuel AST Up to 1,000 gallons Gradual to Towards low spot <br /> AST is located within a containment bernz <br /> Instantaneous within containment <br /> Diesel Fuel AST Fire Up to 1,000 gallons Gradual to Towards Warehouse A AST is located within a containment benzi <br /> Pump and roadwhicall <br /> ay up to tank and is located to o to y downgradient , <br /> Instantaneous p g' p <br /> Diesel Fuel AST area from property botindary <br /> Building D Fire Up to 1,000 gallons Gradual to Towards Storm water AST is located topographically downgradient <br /> Pump Instantaneous Pond #7 from property boundary <br /> Diesel Fuel AST Gradual to Onsite retention. General secondary <br /> Generator Tanks UP to 1,000 gallons Instantaneous owsp Towards lof containment is provided by the design of the <br /> 3iOsal Mixing Tanks Not Applicable No truck loading area.. <br /> o the tanks Not applicable 'hanks are filled using drums and hand pumps <br /> Elena Manzo. REHS Page 6 of 21 <br />