The following is an itemized list of aboveground petroleum storage act violations that <br /> have not been addressed for ESCALON UNIFIED SCHOOL DIST as of November <br /> 30, 2021. <br /> Open violations from August 06, 2021 inspection <br /> Violation#706-Failed to provide and maintain adequate secondary containment for bulk storage tanks. <br /> OBSERVATION:The facility failed to provide and maintain secondary containment for bulk storage tank installations <br /> sufficient to hold the capacity of the largest container, including adequate freeboard for precipitation. <br /> -The 10,000 gallon diesel tank was observed with insufficient secondary containment. In the floor of the dike in the <br /> southwest corner there is a hole with a pipe in it. <br /> -Secondary containment for the used oil, motor oil,gasoline and transmission oil tanks was not discussed in the <br /> SPCC plan. The 1,000 gasoline tank was partially addressed with the oil water separator but portions of the tank <br /> are over soil that does not slope towards the oil water separator. <br /> REGULATION GUIDANCE:(c)(2)Construct all bulk storage tank installations(except mobile refuelers and other <br /> non-transportation-related tank trucks)so that you provide a secondary means of containment for the entire capacity <br /> of the largest single container and sufficient freeboard to contain precipitation.You must ensure that diked areas are <br /> sufficiently impervious to contain discharged oil.Dikes,containment curbs,and pits are commonly employed for this <br /> purpose.You may also use an alternative system consisting of a drainage trench enclosure that must be arranged <br /> so that any discharge will terminate and be safely confined in a facility catchment basin or holding pond. <br /> CORRECTIVE ACTION: Immediately provide and maintain adequate secondary containment for the following bulk <br /> storage tanks: 10,000 gallon diesel tank.Submit proof of correction to the EHD. <br /> ❑ This violation was corrected MThis violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Violation#711 -Plan failed to adequately discuss procedures to test or inspect each container for integrity. <br /> OBSERVATION:The Spill Prevention,Control, and Countermeasure(SPCC)Plan does not adequately discuss <br /> procedures to test or inspect each aboveground container for integrity in accordance with industry standards. The <br /> referenced industry standard,STI SP001,frequency of formal inspections is not mentioned in the SPCC plan. <br /> REGULATION GUIDANCE: (c)(6)Test or inspect each aboveground container for integrity on a regular schedule <br /> and whenever you make material repairs.You must determine, in accordance with industry standards,the <br /> appropriate qualifications for personnel performing tests and inspections,the frequency and type of testing and <br /> inspections,which take into account container size,configuration,and design(such as containers that are: <br /> shop-built,field-erected,skid-mounted,elevated,equipped with a liner,double-walled,or partially buried). Examples <br /> of these integrity tests include, but are not limited to:visual inspection, hydrostatic testing, radiographic testing, <br /> ultrasonic testing,acoustic emissions testing,or other systems of non-destructive testing.You must keep <br /> comparison records, and you must also inspect the container's supports and foundations. In addition,you must <br /> frequently inspect the outside of the container for signs of deterioration,discharges,or accumulation of oil inside <br /> diked areas. Records of inspections and tests kept under usual and customary business practices satisfy the record <br /> keeping requirements of this paragraph. <br /> CORRECTIVE ACTION: Ensure that the SPCC Plan adequately discusses facility's procedures to test and inspect <br /> aboveground/bulk storage containers in accordance with all applicable industry standards.This discussion must <br /> include, but not be limited to, inspection/testing schedule/frequency, and personnel qualifications.Submit proof of <br /> correction to the EHD. <br /> Page 6 of 8 <br />