Laserfiche WebLink
I <br /> Specification sheet Cummins Onan Idogra <br /> w <br /> Commercial <br /> generator set 60 <br /> Quiet Gasoline TM <br /> Series QG 7000 44 <br /> I <br /> Features and benefits Weight, size and sound level <br /> • Integrated hydraulic pump option(pictured) Welghtt: 299 lbs(136 kg) <br /> •Quietest and lowest vibration generator set in Shte: Length 33.6 in(853 mm),width 22.2 in <br /> its class (563 mm),height 16.7 in(425 mm) <br /> • Integrated housing design <br /> • Enclosed muffler for ease of installation Sound: 70 dB(A)at 10 ft(3 m),typical installation, <br /> • Self-diagnostic capability to simplify <br /> full load <br /> troubleshooting <br /> • Runs two ACs with power to spare <br /> • Digital regulation for voltage stability as loads <br /> change <br /> • 2-year limited warranty,5-year drive warranty <br /> Models and ratings <br /> clreud <br /> Model Fuel Hz Wads q12058.3 <br /> PF Phase breaker <br /> 7 HOJAE-2132 Gasoline Tubbed 60 7000 3 1.0 1 2 pole,30 A7 HGJAE-2666e Gasoline Crated 60 7000 2 1.0 1 2 pole,30 A7 HOJAR-1812 Gasoline Tubbed 60 7000 2 1.0 1 2 pole,30 A7 HOJAE-6768• Gasoline Tubbed 60 7000 2 1.0 1 2 pole,30 A7 HGJAE-2127 Gasoline crated 60 7000 8 1.0 3 3 pole,18 A6.5 HGJM-2145 826 LP vapor Tubbed 60 6500 1 1.0 1 2 pole,30 A <br /> 6.5 HGJAE-3664(4666 LP vapor Tubbed 60 6500 120I 54.0 1.0 , 1 2 pole,30 A <br /> - All 60 Hz models operate at 2660 r/min. <br /> - Ratings apply up to 3000 ft(914 m)attitude,85°F(29.40 Q. <br /> - Derating:Power output will decrease 3.5%for each 1000 ft(305 m)above 3000 it(914 m),temperature derete not <br /> required for ambient'temperatures under 120°F(49.2°C).Temperature:Power output decreases 1%for every 10°F <br /> (5.5'C)Increase- <br /> - Ratings are at intermittent power output. <br /> 9 Splined shaft. <br /> Ambient is defined as the air temperature measured at the cooling air inlet to the set. <br /> "Factory OEM packaging <br /> ♦ Evaporative spec:For trailer applications required to meet Tier III Evaporative emissions of the California Air Resources <br /> board. <br /> Effective January 1,2011,gasoline generator sets on trailers,diesel chassis or any other non-motorized mobile <br /> apparatus must have an EVAP generator set,approved tank.EVAP canister,hoses and fittings all meeting the CARB <br /> Tier 3 and EPA phase 3 standards and specifications.This law applies in all 50 states. <br /> Generator weight does not include battery charger or splined shaft. <br /> Performance you mly ori-m cumminsonan.com <br /> 02015 Cummine Pow.Generdlon lm. I A-14411, (any) <br />