Y San -I -Pak Operation Procedure Page 2 of 6 <br />To ensure that Environmental Services (EVS) personnel are competent to operate the San -[-Pak <br />Steam Sterilizer in a safe and systematic manner to keep themselves and others free from harm <br />and danger. <br />Definition: <br />EVS - Environmental Services <br />Text: <br />Biological Testing: <br />1. If a Geobacillus (Bacillus) stearothermophilus indicator has been placed in the load, DO NOT <br />discharge the load by pressing the "Send to Discharge" button. Call a Supervisor or Lead to insert <br />a San -I -Pak master key into the "Sharps" lock. Turn the lock to "Sharps" and then push the "Send <br />to Discharge" button. The chamber will move to the discharge area and wait. Open the blue <br />discharge doors and remove the indicator. Once the indicator has been retrieved, turn the key <br />back to "Off'. The chamber will continue on with the normal procedure of dumping the load and <br />returning home. The master key can be removed now from the "Sharps" lock. <br />2. Biological testing with Geobacillus (Bacillus) stearothermophilus will be done at least monthly. <br />Place the indicator in the middle of the medical waste load. Follow the standard operating <br />procedure to process the indicator. The results will be recorded and kept a minimum of three <br />years. In the case of a positive result (growth), stop operation at this point and notify the EVS <br />Director, Nurse Epidemiologist or Safety Officer. Contact Plant Operations/Engineering if an <br />equipment malfunction is suspected. Indicate on the San -I -Pak Inspection Log what appropriate <br />measures are being taken to correct the problem. Then take those corrective measures before <br />operation is resumed. A successful completion (no growth) of three (3) sterilized indicators in <br />three (3) consecutive cycles must be accomplished before operation can continue. <br />Procedure: <br />Unlock sterilizer door by turning hatch wheel to left until the locking bars release. Pull the door <br />away from the unit until it reaches the end of it's track. <br />On computer pad press "Send to Discharge" then press "OK". Sterilizer chamber will move to the <br />discharge area, dump load, and return home. <br />CAUTION: Keep hands and body completely away from the moving sterilizer chamber. Do not, <br />under any circumstances, touch or try to obstruct the moving chamber. <br />3. To load the chamber — on the computer pad press "Send to Discharge" then press "OK". <br />Chamber will move to the discharge area and wait. <br />4. To tip the chamber up, press "Chamber Load" button (yellow one). <br />5. Open discharge area doors (big blue ones — both of them). <br />6. Bring red tipper cart to compactor and lay the lid completely open against the back of the cart. <br />Prepare autoclave bag by tying all corners — no openings are allowed. Place autoclave tape <br />across the top of the autoclave bag. Note: no sharps containers are to be placed into the sterilizer <br />after 24:00(midnight) the night before the compactor bin is scheduled for pickup. Other medical <br />(infectious) waste can still be sterilized and regular waste can still be compacted. <br />7. Position the tipper in front of the cart lift — front of tipper cart will face the cart lift. Continuously <br />press the "Cart Lift" button (black one). The cart lift will catch the upper part of the tipper cart, lift <br />and dump it into the discharge area. To lower the tipper cart - continuously press the "Cart Lower" <br />button (black one). Lower the tipper cart and move it out of the way. With the tamping pole, push <br />http://dhalts0l /policy/policy.nsf/2b0l 45f9f8 l 80bc2872572760064256414bb8f84767ae 1 f9... 11/15/2016 <br />