My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
N
>
NAGLEE
>
2410
>
3600 - Recreational Health Program
>
PR0515193
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/31/2021 2:38:47 PM
Creation date
8/31/2021 2:37:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0515193
PE
3611
FACILITY_ID
FA0012064
FACILITY_NAME
FAIRFIELD INN
STREET_NUMBER
2410
STREET_NAME
NAGLEE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
21205063
CURRENT_STATUS
01
SITE_LOCATION
2410 NAGLEE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Time In: 1005 am <br />Time Out: 10:45 am <br />�,AFtt.N. San Joaquin County <br />a4� EoG <br />a Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br />.. cT Telephone: (209) 468-3420 Fax: (209) 464-0138 Web: www.sjgov.org/ehd <br />4ctae'A" <br />Swimming Pool Official Inspection Report <br />Name of Facility: FAIRFIELD INN <br />Date: 07/06/2015 <br />Address: 2410 NAGLEE RD, TRACY 95376 <br />Owner/Operator: W 2005/FARGO HOTELS (POOL C) <br />Telephone: (209) 833-0135 <br />Program Element: 3611 - PUBLIC POOL/SPA- PRIMARY <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR"pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#3 Safety Signs <br />OBSERVATIONS: Move'keep closed' signs to the exterior of the doors. Correct in 2 weeks. <br />VIOLATION DESCRIPTION: Pool operatorshall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31208) <br />#4 Safety Equipment <br />OBSERVATIONS: Rope of the life ring is tangled. Untangle rope today. <br />VIOLATION DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed -length rescue pole with a permanently attached body hook and one 17 -inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br />#11 Combined Chlorine Concentration <br />OBSERVATIONS: Combined chlorine at 0.8ppm. Maintain combined chlorine at or below 0.4ppm. Correct today. <br />VIOLATION DESCRIPTION: Pool operator shall maintain combined chlorine concentration below 0.4 ppm. (CCR 65530) Chemical quality <br />of pool water and indoor air quality at the pool site shall not cause adverse physiological effects, such as irritation of the eyes, lungs, or <br />skin. (CCR 65531) <br />#22 Skimmer Assembly <br />OBSERVATIONS: Weirs lacking at both skimmers. Replace in 1 week. <br />O-ring on float valve assembly lacking. Replace in 1 week. <br />VIOLATION DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 31368) <br />Flow rate: 95 <br />OVERALL INSPECTION NOTES AND COMMENTS <br />gpm Chlorine: 2.8 ppm Temp: <br />Cyanuric acid: n/d ppm pH: 7.2 Combined chlorine: 0.8 <br />OF <br />FA0012064 PRO515193 SCO01 07/06/2015 <br />EHD Rev. 06/30/15 Page 1 of 2 Swimming Pool OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.