COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MYRTLE
>
2849
>
2300 - Underground Storage Tank Program
>
PR0538822
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2021 3:33:15 PM
Creation date
9/8/2021 11:32:48 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0538822
PE
2351
FACILITY_ID
FA0022301
FACILITY_NAME
Regional Transportation Center
STREET_NUMBER
2849
Direction
E
STREET_NAME
MYRTLE
STREET_TYPE
St
City
Stockton
Zip
95205
APN
157-020-11
CURRENT_STATUS
01
SITE_LOCATION
2849 E Myrtle St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NMI 1 =1 wvtxHulivu : OFF 0 2 : PIPING DT - 2 <br /> PER TEST AVERAGING * OFF ---_ <br /> TYP : 2 . 0i3 . 0IN FIBERGLASS L 4 : DT - 1 FILL BRINE L190DIESEL DISP - 2 SUMP <br /> TANK. TEST NOTIFY : OFF 2 . 0IN DIA LEN : 220 FEET TRI —STATE ( SINGLE FLOAT ) TRI —STATE ( SINGLE FLOAT ) <br /> OTHER SENSORS CATEGORY: DISPENSER PAN <br /> TNK TST SIPHON BREAKOFF 3 , 0IN DIA LEN : 220 FEET CATEGORY <br /> DELIVERY DELAY 1 t°1IN SHUTDOWN RATE : 3 . 0 GPH <br /> PUMP THRESHOLD 10a00% LOW PRESSURE SHUTOFF : NO L 5 : DT - 1 ANNULAR <br /> DUAL POINT HYDROSTATIC L20 : UIESEL DISP - 3 SUMP <br /> LOW PRESSURE • 0 PSI CATEGORY : ANNULAR SPACE TRI —STATE ( SINGLE FLOAT ) <br /> T 2 : DIESEL TANK2 DT - 2 <br /> CATEGORY : DISPENSER PAN <br /> DISPENSE MODE : <br /> STANDARD <br /> SENSOR : NON —VENTED L 6 : DT - 1 DISP SUMP NR D L21 : DIESEL DISP - 4 SUMP <br /> PRESSURE OFFSET : - 5 . OPSI TRI —STATE ( SINGLE FLOAT ) TRI —STATE ( SINGLE FLOAT ) <br /> MECHANICAL BLENDER : NO CATEGORY DISPENSER PAN CATEGORY soDISPENSER PAN <br /> G 3 : PIPING GT — 1 L 7 : DT - 1 DISP BRINE NR D 22@, <br /> LEAK TEST METHOD TRI —STATE ( SINGLE FLOAT ) TRI —SST - 1 STP SUMP <br /> TYP : 2 . 0,� 3 . 01tV FIBERGLASS TRI —STATE ( SINGLE FLOAT ) <br /> 2 OIN UTA LEN : 72 FEET CATEGORY : OTHER SENSORS CATEGORY STP SUMP <br /> . <br /> TEST ON DATE : ALL TANK <br /> OCT I . 2014 3 , 0IN DIA LEIV : 72 FEET <br /> START TIME : DISABLED L23 : GT — 1 STP BRINE <br /> TEST RATE : 0 . 20 GAL/ HR SHUTDOWN RATE : 3 , 0 GPH L 8 : DT - 2 STP SUMP TRI —STATE { SINGLE FLOAT } <br /> DURATION 2 HOURS LOW PRESSURE SHUTOFF : NO TRI —STATE ( SINGLE FLOAT ) CATEGORY OTHER SENSORS <br /> TST EARLY STOP : DISABLED <br /> LOW PRESSURE : 0 PSI CATEGORY STP SUMP <br /> LEAK TEST REPORT FORMAT T 3 : GASOLIIIE TANK1 GT — I L 9 : DT - 2 STP BRINE <br /> NORMAL DISPENSE MODE : TRI —STATE ( SINGLE FLOAT ) TRI �STATL24 : GT - 1 FILL SUMP <br /> STANDARD CATEGORY upOTHER SENSORS <br /> SENSOR : NON —VENTED CATEGORY E : ( SINGLE <br /> SUMP <br /> PRESSURE <br /> PRESSURE OFFSET : 0 , 0PSI <br /> MECHANICAL BLENDER : NOL25 : GT - 1 FILL BRINE <br /> L10 : DT - 2 FILL SUMP TRI —STATE ( SINGLE FLOAT ) <br /> TRI —STATE ( SINGLE FLOAT ) CATEGORY : PIPING SUMP <br /> CATEGORY PIPING SUMP <br /> L26 : GT - 1 ANNULAR <br /> LiI : DT - 2 FILL BRINE DUAL POINT HYDROSTATIC <br /> TRI —STATE ( SINGLE FLOAT ) CATEGORY : ANNULAR SPACE <br /> PRESSURE LINE LEAK SETUP CATEGORY : OTHER SENSORS <br /> 1, 27 : GT - 1 DISP SUMP NR <br /> 0 1 : PIPING DST - 1 L12 : DT - 2 ANNULAR TRI —STATE ( SINGLE FLOAT ) <br /> DUAL POINT HYDROSTATIC CATEGORY DISPENSER PAN <br /> TYP : 't . Of3 . 0IN FIBERGLASS LINE LEAK LOCKOUT SETUP _ CATEGORY ANNULAR SPACE <br /> 2 . OIN DIA LEN : 300 FEET LOCKOUT SCHEDULE <br /> 3 . 0IN DIA LEN : 220 FEET DAILY <br /> START TIME : DISABLED L13 : DIESEL TRAM SUMP L20 : GT - 1 DISP BRINE NR <br /> SHUTDOWN RATE : 3 . 0 GPH STOP TIME DISABLED TRI —STATE ( SINGLE FLOAT ) TRI —STATE ( SINGLE FLOAT ) <br /> CATEGORY OTHER SENSORS <br /> LOW PRESSURE SHUTOFF : NO CATEGORY PIPING SUMP <br /> LOW PRESSURE : 0 PSI <br /> T I : DIESEL TANKI DT - 1 L14 : DIESEL TRAN BRINE 1, 29 : GT - 1 VENT SUMP <br /> DISPENSE MODE : TRI —STATE ( SINGLE FLOAT ) TRI —STATE ( SINGLE FLOAT ) <br /> STANDARD CATEGORY : PIPING SUMP CATEGORY OTHER SENSORS <br /> SENSOR : NON —VENTED <br /> PRESSURE OFFSET : - 5 . OPSI <br /> L150DIESEL VENT SUMP <br /> MECHANICAL BLENDER : NO TRI —STATE ( SINGLE FLOAT ) L30 : GT - 1 SUMP BRINE <br /> CATEGORY : OTHER SENSORS TRI —STATE ( SINGLE FLOAT ) <br /> LIQUID SENSOR SETUP CATEGORY OTHER SENSORS <br /> L I : DT - 1 STP SUMP L16 : DIESEL VENT BRINE <br /> TRI —STATE ( SINGLE FLOAT ) TRI —STATE ( SINGLE FLOAT ) L31 : AST ANNULAR <br /> CATEGORY : STP SUMP CATEGORY : OTHER SENSORS TRI — STATE ( SINGLE FLOAT ) <br /> CATEGORY : ANNULAR SPACE <br /> L 2 : DT - 1 STP BRINE <br /> TRI —STATE ( SINGLE FLOAT ) L17 : FILTER ROOM LOW PNT <br /> CATEGORY : OTHER SENSORS TRI —STATE ( SINGLE FLOAT ) <br /> CATEGORY OTHER SENSORS <br /> L 3 : DT - 1 FILL SUMP LIB : DI1:SEL DISP - 1 SUMP <br /> TRI —STATE ( SINGLE FLOAT ) TRI —STATE ( SINGLE FLOAT ) <br /> CATEGORY 4 PIPING SUMP CATEGORY 0 DISPENSER PAN <br />