Laserfiche WebLink
/ `~\ SAN J O A Q U I N Environmental Health Department <br /> P <br /> COUNTY Jasjit Kang, REHS, Director <br /> �.a`_ ���.,, Muniappa Naidu,REHS,Assistant Director <br /> oP•__ Greatness crows here. PROGRAM COORDINATORS <br /> Jeff Carruesco, REHS,RDI <br /> Willy Ng,REHS <br /> Steven Shih,REHS <br /> Elena Manzo,REHS <br /> Natalia Subbotnikova,REHS <br /> June 27, 2024 <br /> Rich Rice <br /> PO BOX 657 <br /> Clements, CA 95227 <br /> RE: Water Well Pump Inspection <br /> 27 June <br /> Well Location: 18650 E. Harney Lane Permit#: WP0041566 Inspection Date: 2024 <br /> The Environmental Health Department conducted a water well pump inspection at the above address and <br /> found the following code violations at the time of the inspection. In order to protect the ground water and your <br /> drinking water source from potential degradation, please take the associated corrective actions. <br /> ❑ Lack of or inadequate concrete platform around wellhead. <br /> (SJC Water Well Standards, Section 4.10.—Surface Seal) <br /> Corrective Action: Install a concrete surface seal (pedestal) that is a minimum of 4 inches above <br /> grade and extends 2 feet in all directions from the well casing. (About 5'X5') <br /> ❑ Lack of or inadequate sanitary seal at wellhead. <br /> (SJC Ord. Code,Title 9, Section 9-1115.5.—Well Regulations) <br /> Corrective Action: Install a sanitary seal between casing and well cover plate/seal all gaps and <br /> openings. <br /> ❑x Lack of or Inadequate Sampling Tap. <br /> (SJC Water well Standards, Section 4.13.—Sampling Tap) <br /> Corrective Action: Install a non-threaded sampling tap between the wellhead and the check valve <br /> or within three (3) feet of the well head. Once sample tap is installed I can take <br /> water samples. <br /> ❑ Lack of or inadequate backflow prevention. <br /> (SJC Water Well Standards, Section 4.14.—Backflow Prevention) <br /> Corrective Action: Install an approved protective device to prevent backflow and/or back siphon <br /> into a well. <br /> ❑ Sounding tube or air vent not sealed. <br /> (SJC Water Well Standards, Section 4.13.—Sounding Tube/Air Vent Pipe) <br /> Corrective Action: Sounding Tube or Fill Pipe-Install a watertight, threaded cap at the upper end <br /> of the pipe. Air Vent-extend pipe 12 inches above with end inverted in a <br /> downward direction and covered with 16-mesh screening. <br /> Please contact Aaron Gooderham, SR. REHS, (209) 616-3062, when corrections have been made, and if <br /> you have any questions. <br /> .1_0 <br /> Steven Shih, REHS <br /> Program Coordinator <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/ehd <br />