Laserfiche WebLink
SANd0AQ6,J <br />—COUNTY— <br />Greatness grows here. <br />September 19, 2018 <br />ATTN: Allan Kellerman <br />Pacific Pool & Spa <br />2187 Lighthouse Cir <br />Tracy, CA 95307 <br />Subject: Tracy Hills <br />2230 & 2250 Criseldo Mina Av <br />Tracy, CA 95377 <br />Environmer._.I Health Department <br />Linda Turkatte, REHS, Director <br />Kasey Foley, REHS, Assistant Director <br />PROGRAM COORDINATORS <br />Robert McClellan, REHS <br />Jeff Carruesco, REHS, RDI <br />Michael Kith, REHS <br />Willy Ng, REHS <br />Muniappa Naidu, REHS <br />This letter indicates San Joaquin County Environmental Health Department (EHD) approval of <br />drawings submitted for Tracy Hills subject to the following conditions: <br />1. Fencing shall be a minimum of 5 feet high. Openings, holes or gaps in the <br />enclosure, doors and/or gates shall not allow the passage of a 4 -inch diameter <br />sphere. The enclosure shall be constructed over a hard and permanent material <br />equivalent to concrete: and shall be designed and constructed so that it cannot <br />be readily climbed by small children. Horizontal and diagonal member designs <br />which might serve as a ladder for small children are prohibited. Horizontal <br />members' shall be spaced at least 48 inches apart. No planter or other structures <br />that can be climbed shall be permitted within 5 feet of the outside of the pool <br />enclosure or within a 5 foot arc. <br />2. Hose bibs must be available within 75 feet of all deck areas, and must be <br />protected against backflow. <br />3. Provide the EHD with a photometric plan of the deck area. An adequate amount <br />of deck lighting shall be provided, which is at least three-foot candles. <br />4. The lights in the pool shall be protected by a ground -fault circuit interrupter <br />(GFCI). This will be inspected by the City or County Building Department. <br />5. All deck areas must have a slope of no less than 1 percent (1/8 -inch per foot) but <br />no more than 2 percent (1/4 -inch per foot) away from the pool. <br />6. All pumps, filters, chemical feeders, disinfectant feeders, skimmers and <br />supplemental equipment shall comply with the applicable requirements <br />established by the NSF/ANSI 50-2012. Provide specs. <br />7. Chemical feeders and associated components shall be constructed and installed <br />to prevent uncontrolled discharge or siphoning of chemicals and fumes directly <br />into the pool, its recirculation system, the pool area or ancillary facilities. <br />1868 E. Hazelton Avenue 1 Stockton, California 95205 1 T 209 468-34201 F 209 464-0138 1 www.sjcehd.com <br />