Laserfiche WebLink
SAN�3JOAQUIN <br />COUNTY <br />.res.r <br />t.or F;:fr��55 III;iw <br />Environmental Health Department <br />Swimming Pool Official Inspection Report <br />Time In: 2'30 pm <br />Time Out: 2:45 pm <br />Name of Facility: DRIFTWOOD APARTMENTS <br />Date: 06/12/2018 <br />Address: 800 W GRANT LINE RD, TRACY 95376 <br />Owner/Operator: DRIFTWOOD INVESTORS <br />Telephone: (510) 676-1966 <br />Program Element: 3611 -PUBLIC POOL/SPA- PRIMARY <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closune pursuant to Califomis Code of Regulations (Title 22) section 65545. <br />#7 Pool Deck <br />OBSERVATIONS: Fill up open areas of the pool deck with cement within two weeks. <br />CALCODE DESCRIPTION: An unobstructed 4 -foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br />#9 Ladders and Handrails <br />OBSERVATIONS: tighten loose handrail at the shallow pool entrance within one week. <br />CALCODE DESCRIPTION: A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br />handrails shall be corrosion resistant and shall be rigidly installed. At least one handrail shall extend from the deck to not less than a point <br />above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 31118) Pool <br />operator shall keep ladders and handrails well maintained. (CCR 65535) <br />#22 Skimmer Assembly <br />OBSERVATIONS: Provide missing flapper in the skimmer assembly within two weeks. <br />CALCODE DESCRIPTION: Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br />maintained in accordance with manufacturer specifications. (CBC 3136B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br />Flow rate: 110 gpm <br />Cyanuric acid: <30 ppm <br />NOTES <br />influent 15psi <br />effluent 5psi <br />Loose hand rails. <br />Skimmer lacking flapper. <br />Chlorine. 9.8 ppm <br />pH: <br />7.2 <br />OF <br />Combined chlorine: 0.4 <br />FA0003225 PR0360344 SCO01 06/12/2018 <br />EHD 36-01 Rev. 06/30/15 Page 1 of 2 Swimming Pool OR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />