Laserfiche WebLink
Presto, Carol [EHD] <br /> From: DPaul McWhorter <spccorp@hotmail.com> <br /> Sent: Tuesday, December 21, 2021 8:05 PM <br /> To: Gary delCarlo; Presto, Carol [EHD]; Matt McWhorter <br /> Subject: SPCC Plan/Title 22 Site Assessment <br /> CAUTION:This email is originated from outside of the organization. Do not click links or open attachments unless you recognize the <br /> sender and know the content is safe. <br /> Gary: <br /> Thank you for hosting today's onsite inspection at your facility in Tracy, CA. Please find the following <br /> preliminary findings: <br /> 1. Virtually ALL petroleum-based ASTs passed the periodic integrity testing procedures including a <br /> complimentary 3rd Steel thickness test to monitor historical corrosion. We will not charge for the 3rd <br /> test but felt the prior concerns of San Joaquin-CuPA should be reflected in accordance with directives <br /> from Carol Presto. <br /> 2. We determined you will need to anchor the waste-oil collection facility with either angle-iron <br /> restraints OR water-heating straps as controls against AST movement due to your location in a seismic <br /> zone. We will then require photo proof that the installation is complete. <br /> 3. You will eventually place each of the three (3) 2000-gallon ASTs designated for AvGas, Diesel and <br /> Gasoline on a concrete foundation. We will require either photo proof of the completion of the <br /> concrete foundation or a subsequent inspection by SPC Corp. <br /> 4. You received a Training module which you indicated would be distributed to all of your office-staff, <br /> pilots to insure certification for mandated OSHA/US EPA/APSA training. <br /> 5. SPC Corp will provide a supplemental invoice which will reflect the additional ASTs tested today; Thank <br /> you for having a check prepared for the onsite inspection---we did not anticipate this and are <br /> appreciative. <br /> 6. We will begin documentation including the incorporation of guidelines stipulated by Ms. Janice Witul <br /> of Region IV of US EPA and reviewed, in advance, by Carol Presto of San Joaquin-CupA. <br /> 7. Exempt fertilizer/chemical additive/water tank-distributions were likewise documented and will be <br /> inventoried in the spcc plan although they do not pertain to petroleum-based containers. <br /> 8. The inspection(s) will be reviewed and certified by our PE as a matter reflecting the overall gallonage of <br /> the facility. <br /> Thanks again for coordinating this inspection; have a safe and Merry Christmas. <br /> D. Paul McWhorter, CEO <br /> SPC Corp <br /> i <br />