My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FRONTAGE
>
1002
>
2800 - Aboveground Petroleum Storage Program
>
PR0516198
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/10/2022 2:54:23 PM
Creation date
9/29/2021 9:05:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0516198
PE
2832
FACILITY_ID
FA0000650
FACILITY_NAME
GAS & SHOP
STREET_NUMBER
1002
STREET_NAME
FRONTAGE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
26102012
CURRENT_STATUS
01
SITE_LOCATION
1002 FRONTAGE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJOARIN Environmental Health Department <br /> —COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: I Fee it,Address: Date: <br /> Gemco Ripon Truck Plaza Inc. 1022 E FRONTAGE RD. RIPON February 10, 2020 <br /> General Re"renents for SPCC Plans <br /> 626 CFR 1121(h)(1) Load inglunl deal ng rack containment system not adequateto contain spill .V .R .COS <br /> 627 CFR 1121(h)(2) Failed to provide vehicular departure system for loading and unloading racks .V .R .COS <br /> 628 CFR 112.](ai Falure to pekoe in the Plan discussion of conformance with Federal and State requirements d c oCOS <br /> 112.70 <br /> 629 CFR 112.7(1) Failed to evaluate field constructed container for brittle fracture and take appropriate action mV c oCOS <br /> 630 CFR 112.7(k) Failure to provide general secondary containment or alternative for oil-filled operational equipment mV d oCOS <br /> SPCC Plan Requirements for Onshore Facilities(excluding Production facilities) <br /> 701 CFR 112.8(b)(1) Failureto ensure drainagefrom tllketl areas is restrained by valves or alternative method .V .R .COS <br /> 702 CFR 112.8(bN2) Failed to use manual open-and-closed design valves for the drainage of tllketl areas d d oCOS <br /> 703 CFR 112.8(bN3), Failed to design facility drainage system from untllked areas to retain In the fill mV c oCOS <br /> 112.8t)(4) <br /> 704 CFR 112.8tHS)i Faded to provide two lift pumps fair mere that ane wnMrcus trestmed wt m V m R o COS <br /> 705 CFR 112.8dii Container not compatible with oil stored and storage con tli[i ons mV c oCOS <br /> 706 CFR 112.8di Failed to provide and mai mill n ad aquae secondary containment aV c mCOS <br /> ]0] CFR 112.8di Failu re to toll ow the criteria ofthis section while all owing oral nage of unceaarniated mnwae mV c mCOS <br /> 708 CFR 112.8(cN3Nh1 Failed to maintain records of drainage from tllketl areas m V m R m COS <br /> 709 CFR 112.8di Failed to provide corrosion protection for partially buried tanks m V m R o COS <br /> 710 CFR 112.8di Ran failed to adequately discuss procedures to test or inspect each container for Integrity aV aR oCOS <br /> 711 CFR 112.8di Felled to perform scheduled tank tests or inspections by appropriately qualified personnel mV c mCOS <br /> 712 CFR 112.8di Faded to test or Inspect each container for integrity based on industry standards aV aR mCOS <br /> 713 CFR 112.8di Faded to prowde efective leakage control from detective Internal heating coils mV c mCOS <br /> 714 CFR 112.8di Faded to prowde each container wdh a high level monitoring device a V a R m COS <br /> 715 CFR 112.8(cNBNv) Faded to regularly test liquid level serem,devices to ensure proper operation mV c mCOS <br /> 716 CFR 112.8di Faded to observe effluent treatment frequetly enough to Mee potential discharge mV c mCOS <br /> ]1] CFR 112.8di Fee to promptly wnect visible discharges ani remove accumulations ofodindikad areae aV aR mCOS <br /> 718 CFR 112.8di I Faill locale properly or provide sufficient secondary containmentfor mabik4paGblecWaiters aV aR mCOS <br /> Ull2,8((((((d 112.8di Faledto take corrective action on buried piping when exposed for any remain m V m R m COS <br /> 112.8(dN1) Failed to provide corrosion protection for buried piping •V m R m COS <br /> 112.8(di Failetl to caphlank-fange connection attransferpoint andmarktseign gnarl service aV oR mCOS <br /> 112.8(di Failetl to tlezign pipe zupportzto minimize abrazionlcor antl to allowfe exparreioacanhakion mV mR mCOS <br /> 112.8(di Failetl to regularly Inspect aboveground valves,piping,antl appurtenances mV mR oCOS <br /> 112.8(di Failetl to conduct lntegriry antl leaktesting on burietl piping any time It lis worked on aV aR oCOS <br /> 112.8(di Failetl to atlequately warn vehicles entering facility to protect piping antl othertransfeopestinns oV oR oCOS <br /> 112.8(c)(8) P an failed to adequately dezcrib a overfi 11 p revention method z for each container aV aR .COS <br /> Other 1Rolatiore <br /> 4010 See below Unlisted AdminlstrationlDocumentation violation <br /> FA9WpG50 PA."A'. SCam e'L16202t <br /> FND28u01 R—geno ole Page 3 of Alwve;J Petroleum Sked,Aa OiR <br /> 1868 E. Hazelton Avenue I Stockton,California 95205 1 T 209 488-3420 1 F 209 4840138 1 w.lnv.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.