Laserfiche WebLink
The following is an itemized list of aboveground petroleum storage act violations that <br />have not been addressed for VALLEY PACIFIC LODI PLANT & CARDLOCK as of <br />November 03, 2021. <br />Open violations from January 30, 2019 inspection <br />Violation #627 -Loading/unloading rack containment system not adequate to contain spill. <br />Facility has an area that meets the definition of a loading rack and secondary containment is not sufficient to <br />contain the maximum capacity of the largest single compartment of a truck loaded at the facility, per the SPCC plan. <br />Where loading/unloading rack drainage does not flow into a catchment basin or treatment facility designed to handle <br />discharges, use a quick drainage system for tank car or tank truck loading/unloading racks. You must design any <br />containment system to hold at least the maximum capacity of any single compartment of a tank car or tank truck <br />loaded or unloaded at the facility. Provide an interlocked warning light or physical barrier system, warning signs, <br />wheel chocks or vehicle brake interlock system in the area adjacent to a loading/unloading rack, to prevent vehicles <br />from departing before complete disconnection of flexible or fixed oil transfer lines. Immediately begin implementing <br />the necessary procedures, as described in the Spill Prevention, Control, and Countermeasure Plan, to provide <br />sufficient secondary containment in all tank car and tank truck loading and unloading areas. <br />Note: The SPCC plan has identified the non-compliance and has a proposed secondary containment with sufficient <br />capacity to contain a minimum of 1,800 gallons by May 30, 2019. <br />❑ This violation was corrected <br />❑ Supporting documents included <br />❑ This violation will be corrected by (date): <br />Describe actions taken or will be taken to correct violation: <br />Violation #705 -Container not compatible with oil stored andlor storage conditions. <br />The SPCC plan states that the five, 12,000 gallon diesel storage tanks are re -purposed Underground Storage <br />Tanks (UST) being used as Aboveground Storage Tanks (AST). The SPCC plan states that the ASTs are <br />constructed as USTs and are not compatible as aboveground tanks. Containers shall be compatible with the <br />material stored and the conditions of storage such as pressure and temperature. Immediately transfer the contents <br />to a compatible container, or provide equivalence as allowed by CFR 112.7(a)(2). <br />Note: The SPCC plan has identified the non-compliance and has a proposed replacing the tanks with approved <br />tanks by January 2020. <br />❑ This violation was corrected <br />❑ Supporting documents included <br />❑ This violation will be corrected by (date): <br />Describe actions taken or will be taken to correct violation: <br />Page 1 of 2 <br />