My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
1687
>
1600 - Food Program
>
PR0542219
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/11/2024 3:37:19 PM
Creation date
10/1/2021 12:38:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0542219
PE
1623 - RESTAURANT/BAR 1-20 SEATS
FACILITY_ID
FA0024252
FACILITY_NAME
SUBWAY #67236
STREET_NUMBER
1687
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\ymoreno
Supplemental fields
Site Address
1687 2 N CALIFORNIA ST STOCKTON 95204
Suite #
2
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HOT WATER DEMAND CALCULATIONS <br />GPH HOT WATER DEMAND <br />1. JAN SINK:--------------- 15 GPH <br />2. THREE COMPARTMENT SINK: ------42 GPH <br />3. HAND SINK AND PREP. SINK: -----(3) 5=15 GPH <br />4. LAVATORY:---------------- 5 GPH <br />SUB TOTAL:----------------- 77 GPH <br />FOR SINGLE ESTABLISHMENT <br />TOTAL:- 0.8x82=66 GPH <br />BTUH INPUT REQD =----------66x60°Fx8.33 LB/GAL = 40,724 BTUH <br />0.81 <br />WATER HEATER, AO SMITH CYCLONE -HE- 50 GALLON, 76,000 BTUH IS SELECTED <br />ROOF TOP CONCENTRIC <br />COMB. AIR INTLET & EXHAUST OUTLET <br />(FACTORY FURNISHED) FLASH ROOF & SEAL <br />WATER TIGHT <br />3" PVC <br />1" HOT WATER SUPPLY SHUT OFF VALVES <br />3 GAL. AMTROL <br />EXPANSION TANK <br />3" PVC <br />3/4" COLD WATER SUPPLY <br />WALL STRAP CHECK VALVE <br />TEMPERATURE AND <br />PRESSURE RELIEF <br />VALVE VALVE <br />VACUUM RELIE+,_ _ 1 <br />1/8"xl 1/2" STEEL <br />STRAPS SECURE TO 3/4" <br />FRAMING W/ 1/2"1 <br />1/2" LAG SCREWS. <br />(STRAPS -ICBG <br />APPROVED) ST <br />\ T & P DRAIN LINE <br />\ I / SPILL TO MOP SINK <br />\ / WOLDRITE" WALL <br />"HOLDRITE" WALL SUPPORT \BANGER CABLES <br />WITH SPILLAGE HOLDING \\ // <br />PAN PLATFORM AND FRAMING <br />1" GA <br />/ SEE ARCH PLAN <br />/ I <br />SPILLAGE_I i_6'-0" MIN. TO FLOOR <br />HOLDING PAN <br />3/4" PVC DRAIN <br />TO MOP SINK <br />SINK BELOW <br />GAS WATER HEATER I SCALE: <br />NO SCALE <br />WATER CALCULATIONS <br />O®®om®®assm <br />BUILDING FIXTURE UNITS 17.5 = 13 GPM <br />WATER <br />CW LINE - V <br />SSUNIT <br />BUILDING EXTERNAL PRESSURE LOSS <br />QT <br />PRV SET AT 80 PSI (EXIST.) LOW PRESSURE <br />= 70 PSI. (EXIST.) <br />SIZED FOR 60 PSI (SAFE PRESSURE) <br />0 WATER METER (EXIST.) <br />11-8 PSI <br />0 BACK FLOW PREVENTER (EXIST.) <br />12 PSI <br />0 PRESSURE REDUCING VALVE (EXIST.) <br />- PSI <br />PRESSURE AVAILABLE AT BUILDING ENTRANCE 46.2 PSI <br />BUILDING INTERNAL PRESSURE LOSS <br />1 2.5 <br />BUILDING STATIC PRESSURE HEIGHT <br />MOP SINK <br />14 HEIGHT X 0.434 = <br />6.1 PSI <br />PRESSURE REQUIRED AT FIXTURE: <br />3 <br />FLUSH VALVE: <br />- PSI <br />FLUSH TANK: <br />20 PSI <br />BUILDING TOTAL LOSS: <br />26.1 PSI <br />AVAILABLE PRESSURE FOR FRICTION LOSS <br />HAND SINK (2) <br />TOTAL LENGTH 150 FT X F 1.2 = TOTAL EQUIVALENT LENGTH (T.E.L.) 180 FT <br />(46.2-26.II PSI X 100 FT=180 T.E.L. = 11.2 PSI PER 100 FT <br />4 <br />PIPES SIZED FOR 8 PSUl00LF <br />2 <br />KITCHEN SINK <br />P147 <br />911111 <br />O®®om®®assm <br />®®®�ssassm <br />WATER <br />QUANTITY <br />SSUNIT <br />TOTAL <br />QT <br />TOTAL <br />W <br />SEWER WASTE BELOW <br />------------------ <br />mmomommassm <br />VENT LINE <br />- - <br />WATER CLOSET <br />1 <br />4 <br />4 <br />1 2.5 <br />2.5 <br />MOP SINK <br />1 <br />mmommmmassm <br />3 <br />3 <br />3 <br />FLOOR SINKS / FD <br />4 <br />2 <br />8 <br />_ <br />_ <br />HAND SINK (2) <br />mmmm000sssm <br />2 <br />4 <br />2 <br />2 <br />KITCHEN SINK <br />1 <br />3 <br />3 <br />5 <br />5 <br />o <br />mmmmmmsssm <br />- <br />1 <br />2 <br />4 <br />ICE M/C <br />- <br />CO <br />1 <br />0.5 <br />WASTE & WATER FIXTURE UNITS <br />FIXTURE <br />®®®�ssassm <br />WATER <br />QUANTITY <br />SSUNIT <br />TOTAL <br />QT <br />TOTAL <br />W <br />SEWER WASTE BELOW <br />------------------ <br />mm©®®vovvom <br />VENT LINE <br />- - <br />WATER CLOSET <br />1 <br />4 <br />4 <br />1 2.5 <br />2.5 <br />MOP SINK <br />1 <br />3 <br />3 <br />3 <br />3 <br />FLOOR SINKS / FD <br />4 <br />2 <br />8 <br />_ <br />_ <br />HAND SINK (2) <br />m©©m©vovvom <br />2 <br />4 <br />2 <br />2 <br />KITCHEN SINK <br />1 <br />3 <br />3 <br />5 <br />5 <br />m©©©©vovvom <br />- <br />- <br />1 <br />2 <br />4 <br />ICE M/C <br />- <br />CO <br />1 <br />0.5 <br />WASTE & WATER FIXTURE UNITS <br />FIXTURE <br />WASTE <br />WATER <br />QUANTITY <br />SSUNIT <br />TOTAL <br />QT <br />TOTAL <br />W <br />SEWER WASTE BELOW <br />------------------ <br />V <br />VENT LINE <br />- - <br />WATER CLOSET <br />1 <br />4 <br />4 <br />1 2.5 <br />2.5 <br />MOP SINK <br />1 <br />3 <br />3 <br />3 <br />3 <br />FLOOR SINKS / FD <br />4 <br />2 <br />8 <br />_ <br />_ <br />HAND SINK (2) <br />2 <br />2 <br />4 <br />2 <br />2 <br />KITCHEN SINK <br />1 <br />3 <br />3 <br />5 <br />5 <br />PREP. SINK <br />- <br />- <br />1 <br />2 <br />4 <br />ICE M/C <br />- <br />CO <br />1 <br />0.5 <br />1.5 <br />CW OUTLETS <br />- <br />POC <br />- <br />1 <br />2 <br />LAV <br />1 <br />1 <br />1 <br />2 <br />2 <br />TOTAL <br />CO CLEANOUT ORD OVERFLOW ROOF DRAIN <br />HDR HEADER PRV PRESSURE REDUCING VALVE <br />25 <br />I.E. INVERT ELEVATION (E) EXISTING <br />17.5 <br />SEWER LINE - 4" (25 FU) <br />CURVE (FLUSH TANK) - WATER LINE =1J' (17.5 FU), 15 GPM <br />(EXISTING) <br />GPM <br />13 <br />GENERAL NOTES P14A <br />1. ALL WORK SHALL CONFORM TO 2016 CPC. <br />INCLUDING INSTALLATION OF ALL REQUIRED CLEANOUTS PER, 2016 CPC <br />2. VERIFY SIZE, DEPTH, LOCATION AND ADEQUACY OF ALL UTILITIES, <br />INCLUDING METER LOCATIONS AND SEWER INVERTS, BEFORE <br />STARTING WORK. <br />3. ALL PIPING IN FINISHED AREAS SHALL BE CONCEALED WHERE <br />POSSIBLE,AND EXPOSED PIPING SHALL BE RUN AS HIGH AS POSSIBLE <br />AND TIGHT TO WALLS. <br />4. ALL LINES TO BE AWAY FROM BEARING FOOTINGS, OR AS DIRECTED BY <br />STRUCTURAL ENGINEER. <br />5. INSTALL BACKFLOW PROTECTION DEVICES AS REQUIRED BY <br />LOCAL CODES. <br />6. INSTALL PRESSURE REDUCING VALVE(S) WITH SHUT-OFF WHERE CITY <br />PRESSURE EXCEEDS 80 PSI. <br />7. ALL APPLIANCE AND PLUMBING VENTS SHALL BE AT LEAST TEN (10) <br />FEET IN HORIZONTAL DIRECTION OR THREE (3) FEET ABOVE THE OUTSIDE <br />AIR INTAKES FOR HVAC UNITS. <br />8. SEWER TO BE RUN @ 1/4" SLOPE AS PER 2016 CPC PLUMBING CODE. <br />9. ALL REQUIRED CLEANOUTS SHALL BE INSTALLED <br />AS PER 2016 CPC <br />10. ALL EXTERIOR HOSE BIBS SHALL BE PROVIDED WITH NON REMOVABLE <br />BACK FLOW PREVENTION DEVICES AND VACUUM BREAKERS. <br />11. PROVIDE SHUT OFF VALVES FOR ALL PLUMBING FIXTURES AND GROUPS. <br />12. PROVIDE ACCESS PANELS FOR ALL GROUPS OF TOILET FIXTURES. <br />13. PROVIDE TRAP PRIMERS FOR TRENCH DRAINS. <br />14 USE DIELECTRIC UNIONS TO CONNECT STEEL AND COPPER OR BRASS <br />PIPES & FIXTURES. <br />SYMBOLS AND LEGEND <br />SYMBOLS <br />ABBREV <br />DESCRIPTION <br />TR <br />W <br />SEWER WASTE ABOVE <br />HW <br />----------- <br />W <br />SEWER WASTE BELOW <br />------------------ <br />V <br />VENT LINE <br />- - <br />CW <br />COLD WATER <br />- <br />HW <br />HOT WATER <br />BELOW GRADE <br />HWR <br />HOT WATER RETURN <br />-...-._-...-...-... --- ...-...-...- <br />---------GW--------- <br />GW <br />GREASE WASTE <br />G <br />G <br />GAS <br />CD <br />CD <br />CONDENSATE DRAIN <br />PS <br />1 <br />SOL <br />SOIL ,WASTE ABOVE FLOOR OR GRADE <br />H <br />CWV <br />CWV <br />COMBINATION WASTE & VENT <br />DS <br />DS <br />DOWNSPOUT <br />19 <br />2" <br />NEW TO EXISTING CONNECTION <br />Q <br />FS <br />FLOOR SINK <br />IF) <br />WCO <br />WALL CLEAN OUT <br />$ <br />CO <br />CLEAN OUT TO GRADE <br />® <br />FD <br />FLOOR DRAIN <br />Q <br />POC <br />POINT OF CONNECTION <br />,--TPS <br />TP <br />TRAP PRIMER <br />AP ACCESS PANEL RIC ROUGH -IN & CONNECT <br />ASR AUTO. FIRE SPRINKLER RISER RD ROOF DRAIN <br />BFT BACKFLOW PREVENTER SOC SHUT OFF COCK <br />BC BALANCING COCK SOV SHUT OFF VALVE <br />CB CATCH BASIN NA NOT APPLICABLE <br />COYB CLEANOUT IN YARD BOX N.I.C. NOT IN CONTRACT <br />CO CLEANOUT ORD OVERFLOW ROOF DRAIN <br />HDR HEADER PRV PRESSURE REDUCING VALVE <br />I.D. INDIRECT DRAIN (1) NEW <br />I.E. INVERT ELEVATION (E) EXISTING <br />MH MANHOLE <br />PLUMBING FIXTURE SCHEDULE <br />ITEM <br />DESCRIPTION <br />WST <br />TR <br />VT <br />CW <br />HW <br />SPECIFICATIONS & REMARKS <br />IM <br />1 <br />ICE M/C ABOVE BEVERAGE <br />_ <br />_ <br />STORM <br />DRAIN <br />1/2" <br />_ <br />OWNER FURNISHED - PROVIDE INLINE FILTER <br />DISPENSER <br />BELOW GRADE <br />HOT AND COLD <br />COPPER TYPE "L" <br />WROUGHT COPPER <br />ABOVE GRADE <br />KS <br />I <br />3 COMPARTMENT SINK <br />2" <br />1-1/2" <br />1-1/2" <br />3/4" <br />3/4" <br />OWNER FURNISHED TO GREASE WASTE <br />PS <br />1 <br />PREP. SINK <br />- <br />H <br />INDIRECT WASTE <br />1/2" <br />1/2" <br />OWNER FURNISHED -INDIRECT DRAIN TO FS <br />HS <br />1&2 <br />HAND SINK <br />2" <br />2" <br />1-1/2" <br />1/2" <br />1/2" <br />OWNER FURNISHED, HS -1 TO GREASE WASTE <br />FS <br />1 <br />FLOOR SINK <br />2" <br />2" <br />1-1/2" <br />_ <br />_ <br />JAY R. SMITH OR EQUAL, C.I. ENAMEL -HALF GRATE <br />WITH P -TRAP CONN. <br />GALLON, 76,000 BTUH INPUT, 83 GPM RECOVERY AT 60° F TEMP. RISE, <br />WH <br />WATER HEATER A.O. SMITH50 <br />3/4" <br />I" <br />93% THERMAL EFFICIENCY, (2) 3"0 PVC COMB. AIR & VENT WITH ROOF TOP <br />1 <br />CYCLONE -HE <br />CONCENTRIC UNIT <br />WT:- 650 lbs <br />TRAP PRIMER <br />TP <br />INSTALL IN WALL AS SHOWN WITH <br />1/2" <br />- <br />PRIME PERFECT <br />1 <br />DISTRIBUTION UNITS AS INDICATED <br />PER MFGRS. INSTRUCTIONS. <br />MS <br />1 <br />MOP SINK2" <br />2" <br />1 1/2" <br />1/2" <br />1/2" <br />FIAT, WITH CW/HW MIXING FAUCET WITH MOP HOLDER <br />(SEE FLOOR PLAN FOR SIZE) TO GREASE WASTE <br />FD <br />1 <br />FLOOR DRAIN <br />2" <br />2" <br />1 1/2" <br />J.R. SMITH OR EQUAL TO GREASE WASTE <br />WC <br />1 <br />WATER CLOSET <br />4" <br />INT. <br />2" <br />1/2" <br />- <br />AMERICAN STANDARD -CADET ELONGATED <br />BOWL, BLADDER ASSISTED FLUSH TANK, 1.28 <br />GPF, ADA COMPLIANT, <br />I <br />LeAVATORY <br />2" <br />2" <br />1 1/2" <br />1/2" <br />1/2" <br />AMERICAN STANDARD -"LUCERNE", WALL <br />MOUNTED, 0.5 GPM, SELF CLOSING HW/CW <br />MIXING FAUCET, ADA COMPLIANT. <br />DW <br />1) <br />DISHWASHER <br />2" <br />2" <br />11/2" <br />1/2" <br />I <br />- <br />I <br />OWNER FURNISHED <br />I <br />NOTES: <br />I. ALL PLUMBING WASTE CONNECTIONS SHALL COMPLY WITH LOCAL BLDG. DEPT. <br />2. ALL PLUMBING FIXTURES SHALL BE LOW WATER CONSUMPTION TYPE. <br />3. FLOOR SINKS & FLOOR DRAINS- FLUSH WITH FLOOR <br />PIPE MATERIAL SCHEDULE <br />SERVICE <br />PIPE <br />FITTINGS <br />LOCATION <br />WASTE & <br />CAST IRON NO HUE <br />CAST IRON NO HUB <br />ABOVE GRADE <br />VENT <br />LUCnLI <br />BELOW GRADE <br />STORM <br />DRAIN <br />CAST IRON NO <br />CAST IRON NO HUB <br />ABOVE GRADE <br />ULLz <br />BELOW GRADE <br />HOT AND COLD <br />COPPER TYPE "L" <br />WROUGHT COPPER <br />ABOVE GRADE <br />WATER <br />HARD DRAWN <br />>_�� <br />COLD <br />COPPER TYPE "L" <br />WROUGHT COPPER <br />BELOW GRADE <br />WATER <br />HARD DRAWN <br />H <br />INDIRECT WASTE <br />COPPER TYPE "M" <br />WROUGHT COOPER <br />ABOVE GRADE <br />CONDENSATE DRAIN <br />HARD DRAWN <br />GAS <br />BLACK STEEL <br />SCREWED <br />ABOVE GRADE <br />NOTE:- GAS LINE IS EXISTING. <br />FA <br />ii <br />cn <br />O co <br />04 <br />CD <br />y ' <br />M <br />-1 <br />61 <br />O p <br />r ti <br />d �. <br />U X <br />(0 <br />LL <br />00 n <br />N O <br />0000 <br />ai <br />E <br />c <br />y O <br />c � <br />W O <br />5 C <br />�C Y <br />O N <br />N 0 <br />O <br />� U <br />c <br />ID cn <br />E `) <br />O N <br />U E <br />U <br />L:) ca> <br />d <br />c6 O <br />CL <br />c70 E <br />C J � <br />O N <br />JL � <br />m <br />0 C 0) <br />W <br />(D <br />DATE: 02/06/2017 <br />JOB: PT -ST -05 <br />DWG BY: KS <br />CHK BY: APV <br />P1 <br />W <br />Lu <br />W <br />z <br />2 <br />I--. LU <br />Lu O. -I <br />LUCnLI <br />LU <br />>Qm <br />> <br />�zQ <br />O <br />ULLz <br />QUO <br />azo <br />MZ <br />W <br />�O <br />>_�� <br />m <br />.J <br />EL <br />H <br />F <br />U <br />W <br />0 <br />F <br />a <br />DATE: 02/06/2017 <br />JOB: PT -ST -05 <br />DWG BY: KS <br />CHK BY: APV <br />P1 <br />