TELEPHONE SYSTEM NOTES: ELECTRICAL SYMBOL LEGEND (SOME MAY NOT BE USED)
<br /> SYMBOL DESCRIPTION SYMBOL DESCRIPTION
<br /> GENERAL CONTRACTOR SHALL CONTACT STARBUCKS GLOBAL NETWORK $ WALL MOUNTED SINGLE RECEPTACLE, NEMA 5-20R ® PANELBOARD, UTILITY POWER
<br /> OPERATIONS CENTER (GNOC) PRIOR TO BEGINNING CONSTRUCTION TO ORDER POWER DISTRIBUTION PANEL OR q►
<br /> TELEPHONE LINES. WALL MOUNTED DUPLEX RECEPTACLE ® SWITCHBOARD, UTILITY POWER
<br /> © REPORT ANY TELEPHONE INSTALLATION ISSUES IMMEDIATELY TO STARBUCKS WALL MOUNTED DEDICATED DUPLEX RECEPTACLE g METER AND SOCKET
<br /> GLOBAL NETWORK OPERATIONS CENTER (GNOC) VIA EMAIL: GNOC@STARBUCKS.COM. WALL MOUNTED DUPLEX RECEPTACLE, ONE RECEPTACLEJ WALL MOUNTED JUNCTION/OUTLET BOX
<br /> SWITCHED OR SPLIT—WIRED
<br /> © CONFIRM PRIOR TO BEGINNING CONSTRUCTION THAT LANDLORD HAS :# WALL MOUNTED QUADRUPLEX RECEPTACLE FLUSH FLOOR MOUNTED JUNCTION/OUTLET BOX
<br /> FURNISHED AND INSTALLED (1) 1� CONDUIT INCLUDING PULL STRING FROM WALL MOUNTED DEDICATED QUADRUPLEX RECEPTACLE J CEILING MOUNTED JUNCTION/OUTLET BOX
<br /> THE TELEPHONE POINT OF PRESENCE TO THE STARBUCKS WORKROOM. NOTIFY D c
<br /> STARBUCKS CONSTRUCTION MANAGER (SEE SHEET G1.0) ©2017 STARBUCKS COFFEE COMPANY
<br /> IMMEDIATELY IF CONDUIT AND PULL STRING ARE NOT INSTALLED. � WALL MOUNTED QUADRUPLEX RECEPTACLE, SPLIT—WIRED Q JUNCTION BOX MOUNTED ABOVE CEILING
<br /> AS NOITED NTED SPECIAL RECEPTACLE, NEMA CONFIGURATION � MULTI—OUTLET ASSEMBLY STARBUCKS COFFEE
<br /> OD ALL TELEPHONE/NETWORK CABLING IS THE SCOPE OF WORK OF THE WALL MOUNTED RANGE RECEPTACLE NEMA 14-50R UNLESS
<br /> TELEPHONE/NETWORK CABLING VENOR AND THE SECURITY SYSTEM VENDOR. INDICATED OTHERWISE 1 CORD AND PLUG COMPANY
<br /> TELEPHONE/NETWORK CABLING VENDOR SHALL BE SCHEDULED SUCH THAT FLUSH FLOOR MOUNTED SINGLE RECEPTACLE, NEMA 5-20R MOTOR
<br /> CABLING IS COMPLETE PRIOR TO ARRIVAL OF SECURITY SYSTEM VENDOR. 2401 UTAH AVENUE SOUTH
<br /> FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE XX/X SEATTLE,WASHINGTON 98134
<br /> E GENERAL CONTRACTOR SHALL SCHEDULE ON-SITE WORK PERFORMED BY THE ® XXA SAFETY O
<br /> SWITCH, SIZE AS INDICATED ON PLAN (206)318-1575
<br /> TELEPHONE/NETWORK CABLING VENDOR AND THE SECURITYSYSTEM VENDOR. FLUSH FLOOR MOUNTED DEDICATED DUPLEX RECEPTACLE FUSES
<br /> THESE DRAWINGS AND SPECIFICATIONS ARE
<br /> THE TELEPHONE/NETWORK CABLING VENDOR SHALL BE SCHEDULED SUCH FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE, SPLIT—WIRED XXX CONFIDENTIAL AND SHALL REMAIN THE SOLE
<br /> THAT CABLING IS COMPLETE PRIOR TO ARRIVAL OF THE SECURITY ® XXA COMBINATION MAGNETIC MOTOR STARTER AND
<br /> SYSTEM VENDOR. FLUSH FLOOR MOUNTED QUADRUPLEX RECEPTACLE FUSES DISCONNECT SWITCH, SIZE AS INDICATED ON PLAN PROPERTY OF STARBUCKS CORPORATION,
<br /> ® WHICH IS THE OWNER OF THE COPYRIGHT IN
<br /> ® FLUSH FLOOR MOUNTED DEDICATED QUADRUPLEX RECEPTACLEMOD SWITCH. SPST UNLESS INDICATED WITH MODIFIER. HORSEPOWER THIS WORK. THEY SHALL NOT BE
<br /> RATED WHEN USED FOR MOTOR CONTROL OR DISCONNECTING REPRODUCED(IN WHOLE OR IN PART), SHARED
<br /> NOTES:
<br /> FLUSH FLOOR MOUNTED QUADRUPLEX RECEPTACLE, MEANS. WITH THIRD PARTIES OR USED IN ANY MANNER
<br /> T-MOBILE / T1 SPLT—WIRED FLUSH FLOOR MOUNTED SPECIAL RECEPTACLE, WIT H MODIFIERS, INCLUDING THEREOF: ON OTHER PROJECTS OR EXTENSIONS TO THIS
<br /> ® NEMA CONFIGURATION AS NOTED 3: 3—WAY (SPDT). PROJECT WITHOUT THE PRIOR WRITTEN
<br /> ABOVE FLOOR SERVICE FITTING, HUBBELL #SC3098A OR 4: 4—WAY. CONSENT OF STARBUCKS CORPORATION.
<br /> ALL CABLING AND INFRASTRUCTURE TO SUPPORT THE T-MOBILE T-1 HOTSPOT ® EQUAL; NEMA CONFIGURATION AS NOTED D: DIMMER. THESE DRAWINGS AND SPECIFICATIONS ARE
<br /> F: BOX COVER UNIT, BUSSMANN SSU OR STY SERIES.
<br /> OR WI-FI NETWORK SHALL BE FURNISHED AND INSTALLED BY T-MOBILE. CEILING MOUNTED SINGLE RECEPTACLE, NEMA 5-20R G: GLOW HANDLE (HANDLE GLOWS WHEN SWITCH IS OFF). INTENDED TO EXPRESS DESIGN INTENT FOR A
<br /> MC/DC (C=FLUSH CEILING, DC=DROPCORD H: HORIZONTALLY MOUNTED. PROTOTYPICAL STARBUCKS STORE(WHICH IS
<br /> FILING MOUNTED DUPLEX RECEPTQ CLE K: KE OPERATED.
<br /> OA THE T-MOBILE T-1 CIRCUIT WILL BE ORDERED BY T-MOBILE AND COORDINATED EMC/DC ( _ ) M: MANUAL MOTOR CONTROLLER WITH OVERLOAD HEATER. SUBJECT TO CHANGE AT ANYTIME)AND DO
<br /> C—FLUSH CEILING DC=DROPCORD
<br /> THROUGH STARBUCKS HOTSPOT DEPLOYMENT TEAM. NOT ALL STORES WILL SB: SWITCH BANK (GANGED SWITCHES CEILING MOUNTED DEDICATED DUPLEX RECEPTACLE OS1: OCCUPANCY SENSOR. ) NOT REFLECT ACTUAL SITE CONDITIONS.
<br /> HAVE THIS CIRCUIT INSTALLED AT THE NEW STORE OPENING DATE, BUT A ®C/DC (C=FLUSH CEILING, DC=DROPCORD) OS2: DUAL—RELAY OCCUPANCY SENSOR. NEITHER PARTY SHALL HAVE ANY OBLIGATION
<br /> CABLE EXTENSION FOR THIS CIRCUIT WILL BE PROVIDED BY STARBUCKSCEILING MOUNTED DUPLEX RECEPTACLE, SPLIT—WIRED OSD: OCCUPANCY SENSOR/DIMMER. NOR LIABILITY TO THE OTHER(EXCEPT STATED
<br /> TELEPHONE/NETWORK CABLING VENDOR AT THE SAME TIME AS THE ®C/DC C=FLUSH CEILING, DC=DROPCORD P.
<br /> TI:
<br /> LIGHT (PILOT ON WHEN SWITCH IS ON). ABOVE)UNTIL A WRITTEN AGREEMENT IS
<br /> TELEPHONE/NETWORK EXTENSIONS FOR FUTURE USE. CEILING MOUNTED QUADRUPLEX RECEPTACLE LV: LOW VOLTAGE. FULLY EXECUTED BY BOTH PARTIES.
<br /> ®C/DC (C=FLUSH CEILING, DC=DROPCORD) OR: OVERRIDE.
<br /> CEILING MOUNTED DEDICATED QUADRUPLEX RECEPTACLE OT: OVERRIDE WITH TIMER.
<br /> ®C/DC (C=FLUSH CEILING, DC=DROPCORD) WP: WEATHERPROOF
<br /> DTC: SPDT, CENTER OFF, MAINTAINED CONTACT. ARCHITECT OF RECORD
<br /> ®C/DC (CILFLUSHING OUNTED CEI NG,QDCDDROPCORD)RUPLEX RECEPTACLE, SPLIT—WIRED LOWERCASE LETECENTER FF
<br /> OONTROL LUMINAIMOMENTARY RE WITHT.
<br /> SAME LETTER. mcg architecture
<br /> CEILING MOUNTED SPECIAL RECEPTACLE, NEMA CONFIGURATION S CEILING MOUNTED PHOTOSENSOR y
<br /> MC/DC AS NOTED (C=FLUSH CEILING, DC=DROPCORD) _ z
<br /> U � N
<br /> SECURITY SYSTEM NOTES:
<br /> BRANCH CIRCUITING, CONCEALED IN WALL OR CEILING OS CEILING MOUNTED OCCUPANCY SENSOR Lz i�—�� BRANCH CIRCUITING, CONCEALED IN OR UNDER FLOOR �OS WALL MOUNTED OCCUPANCY SENSOR in
<br /> BRANCH CIRCUITING, EXPOSED XX� TRK LIGHTING LIVE END FEED;
<br /> OA STARBUCKS CONTRACTS DIRECTLY WITH SECURITY VENDOR TO SUPPLY & 'xx"ACINDICATES CURRENT LIMITER RATING IF APPLICABLE 111 Pacifica,Suite 280,Irvine,CA 92618
<br /> SOW,VOLTAGE LIGHTING POWER SUPPLY TRANSFORMER; P:949.553.1117 F:949.474.7056
<br /> INSTALL THE SECURITY SYSTEM. CONTRACTOR TO SCHEDULE INSTALLATION HOMERUN TO PANEL. THE NUMBER OF ARROWS INDICATES THE XXX RPS XXX INDICATES VOLT—AMP RATING
<br /> OF SECURITY SYSTEM FOR TWO TIMES, ROUGH-IN PRIOR TO DRYWALL NUMBER OF CIRCUITS. TWO WIRES UNLESS NOTED OTHERWISE; FLOOR MOUNTED TELEPHONE OUTLET;
<br /> INSTALLATION AND FINAL TRIM PRIOR TO STORE TURNOVER, SECURITY VENDOR SLASHES INDICATE NUMBER OF WIRES. GROUND WIRE IS *P DENOTES NUMBER OF TELEPHONE PORTS ENGINEER STAMP of E SS i
<br /> REQUIRED BUT NOT INDICATED. A 7 INDICATES ISOLATED R o
<br /> REQUIRES A MINIMUM TWO WEEKS LEAD TIME FOR EACH INSTALLATION. SECURITY GROUND CONDUCTOR. CEILING MOUNTED TELEPHONE OUTLET; o Q Nq�
<br /> VENDOR WILL COORDINATE REGIONAL INSTALLERS. ALL ADDITIONAL EXPENSES mflC *P DENOTES NUMBER OF TELEPHONE PORTS ��, �y ROY Scyti Fy
<br /> INCURRED DUE TO THE CONTRACTOR'S FAILURE TO SCHEDULE ACCORDINGLY ] CONDUIT STUB - WALL MOUNTED TELEPHONE OUTLET;
<br /> WILL BE THE RESPONSIBILITY OF THE CONTRACTOR *P DENOTES NUMBER OF TELEPHONE PORTS a--
<br /> VERTICAL
<br /> VERTICAL CONDUIT/CIRCUIT FLOOR MOUNTED DATA OUTLET; 0 CD No. E14631 r m
<br /> *D DENOTES NUMBER OF DATA PORTS w
<br /> SECURITY VENDOR I D BELL *CEILING MOUNTED DATA OUTLET;
<br /> D
<br /> THE DIEBOLD COMPANY C DENOTES NUMBER OF DATA PORTS
<br /> CONTACT: STARBUCKS PROJECT MANAGEMENT TEAM I_Y BUZZER 0 WALL MOUNTED DATA OUTLET; ,� �EcrR,cP`' �P
<br /> *D DENOTES NUMBER OF DATA PORTS
<br /> PHONE: 206 318 6688 FLOOR MOUNTED COMBINATION TELEPHONE AND DATA OUTLET; F of CALkFo
<br /> EMAIL: DOCC.STARBUCKS@DIEBOLD.COM B CHIME *P *D DENOTES NUMBER OF TELEPHONE DATA PORTS
<br /> pS SPEAKER, CEILING CEILING MOUNTED COMBINATION TELEPHONE AND DATA OUTLET;
<br /> C *P *D DENOTES NUMBER OF TELEPHONE DATA PORTS Date. 03/24/2020
<br /> S SPEAKER, WALL WALL MOUNTED COMBINATION TELEPHONE AND DATA OUTLET,
<br /> P D DENOTES NUMBER OF TELEPHONE DATA PORTS
<br /> COMMUNICATION SYS. NOTES: SOG SPEAKER, GROUND—MOUNTED m " SICKPLYODBDRARD'SZEAINDICATED AWI
<br /> VC VOLUME CONTROL TV FLOOR MOUNTED TELEVISION OUTLET
<br /> OA STARBUCKS CONTRACTS DIRECTLY WITH THE LANDLORD TO PROVIDE FOUR (4) AMP ❑SOUND SYSTEM AMPLIFIER Tv CEILING MOUNTED TELEVISION OUTLET
<br /> CATS (WHITE) COMMUNICATION CABLES TO THE SPACE. 0 C
<br /> FOUR (4) CATS CABLES ARE DEDICATED TO STORE OPERATIONS/ TR LOW VOLTAGE CONTROL TRANSFORMER WALL MOUNTED TELEVISION OUTLET
<br /> COMMUNICATIONS.
<br /> TC AUTOMATIC TIMECLOCK 0 PUSHBUTTON STATION, ONE BUTTON q;T
<br /> ® RELAY Eil PUSHBUTTON STATION, TWO BUTTON W 0
<br /> J N
<br /> MUSIC NOTES: PC PHOTOCELL ••• PUSHBUTTON STATION, THREE BUTTON _/'� LO
<br /> L.L w
<br /> ® CARBON MONOXIDE SENSOR Q
<br /> OA PROVIDE AND INSTALL A COMPLETE WIRING SYSTEM FOR ALL SPEAKERS. CC CO Q V
<br /> CONNECT ALL SPEAKERS TO THE OWNER PROVIDED MUSIC SYSTEM. MOUNT G to (�
<br /> OWNER FURNISHED SPEAKERS WHERE SHOWN AND IN COORDINATION WITH
<br /> ARCHITECTURAL PLANS AND DETAILS. FOLLOW MANUFACTURER'S INSTALLATIONLu 06
<br /> A R VIATI N AN M IFI R (SOMEMAY N T o Z
<br /> BB E O S D OD E S 0 BE USED) - p
<br /> REQUIREMENTS. (� Q
<br /> AFF ABOVE FINISHED FLOOR SPST SINGLE POLE, SINGLE THROW WP WEATHERPROOF MODIFIER Z
<br /> AFG ABOVE FINISHED GRADE DPST DOUBLE POLE, SINGLE THROW PT POKE—THROUGH MODIFIER POS1--
<br /> LL U
<br /> / DATA LINE ■ NIC NOT IN CONTRACT 3PST THREE POLE, SINGLE THROW H HORIZONTAL MOUNT MODIFIER ODIFIER w - w
<br /> N F. NON—FUSED UNO UNLESS IED OTHERWISE SPDT SINGLE POLE,4PST FOUR POLE, DOUBLE THNGLE ROW G ISOLATEDW HG TAL DNDMMODIFIER0 v � 0 p
<br /> GFPE GROUND—FAULT PROTECTION OF EQUIPMENT DPDT DOUBLE POLE, DOUBLE THROW TR TAMPER—RESISTANT MODIFIER 0 Q 0� 00
<br /> OA DATA CABLING REFERENCED IN THIS SECTION IS SEPARATE FROM THE ST SHUNT TRIP MODIFIER 3PDT THREE POLE, DOUBLE THROW SP SURGE PROTECTION MODIFIER 10- 0- U)
<br /> TELEPHONE AND T-1 CIRCUITS GND GROUND 4PDT FOUR POLE, DOUBLE THROW GFCI GROUND—FAULT CIRCUIT INTERRUPTER
<br /> EGC EQUIPMENT GROUNDING CONDUCTOR EM EMERGENCY LIGHT MODIFIER MODIFIER
<br /> GEC GROUNDING ELECTRODE CONDUCTOR NL NIGHTLIGHT LUMINAIRE MODIFIER SR SHOW WINDOW RECEPTACLE MOUNTED WITHIN STORE #: 5470
<br /> © STARBUCKS CONTRACTS DIRECTLY WITH THE DATA CABLING VENDOR TO AHJ AUTHORITY HAVING JURISDICTION +XX" MOUNTING HEIGHT MODIFIER 18 INCHES OF TOP OF SHOW WINDOW
<br /> SUPPLY AND INSTALL CATEGORY 5 LAN CABLE AND CONNECTORS FOR THE NEC NATIONAL ELECTRICAL CODE (NEPA 70) CR CONTROLLED RECEPTACLE MODIFIER PROJECT#: 03030-052
<br /> POS SYSTEM. CONTRACTOR TO SCHEDULE INSTALLATION OF DATA CABLING CH CLOCK HANGER RECEPTACLE CASEWORK CONCEPT: CORE
<br /> W/ DATA CABLING VENDOR. DATA CABLING VENDOR REQUIRES A LEAD TIME
<br /> FOR INSTALLATION. DATA CABLING VENDOR WILL COORDINATE REGIONAL ISSUE DATE: CHECKSET 2-10-20
<br /> INSTALLERS. ALL ADDITIONAL EXPENSES INCURRED DUE TO THE CONTRACTOR'S PROGRAM MANAGER: M. DBREBIKA
<br /> FAILURE TO SCHEDULE ACCORDINGLY WILL BE THE RESPONSIBILITY OF THE STORE DESIGNER: M. DBREBIKA
<br /> CONTRACTOR. LEER®AP: N/A
<br /> © AT THE START OF CONSTRUCTION, STARBUCKS CM SCHEDULES DELIVERY OF CHECKED BY: A. FELDMAN
<br /> CASH REGISTER/MANAGER'S WORKSTATION EQUIPMENT AND INSTALLATION BY MCG PROJECT#: 18531
<br /> A DATA CABLING TECHNICIAN FOR TWO DAYS PRIOR TO CONSTRUCTION END. MCG PROJ. MANAGER: C. LEE
<br /> CONTRACTOR TO VERIFY DELIVERY SCHEDULE TWO WEEKS PRIOR TO DELIVERY MCG PROD. SPECIALIST: S.PARK
<br /> AND INSTALLATION DATE. EQUIPMENT IS SHIPPED DIRECTLY TO THE STORE,
<br /> CONTRACTOR TO ACCEPT POS EQUIPMENT DELIVERY, DO NOT REFUSE DELIVERY.
<br /> Revision Schedule
<br /> O DATA CABLING TECHNICIAN TO PROVIDE ALL CATEGORY 5 LAN CABLING AND
<br /> CONNECTIONS TO ALL DESIGNED AND FUTURE CASH REGISTER LOCATIONS, AND Rev Date By Description
<br /> MANAGER'S WORKSTATION.
<br /> O DATA CABLING TECHNICIAN TO REMOVE PACKAGING, INSTALL AND TEST CASH
<br /> REGISTERS, CASH DRAWERS AND MANAGER'S WORKSTATION.
<br /> OF STARBUCKS NEW STORE GROUP IS RESPONSIBLE FOR COORDINATING
<br /> STARBUCKS POS SYSTEM DELIVERY AND INSTALLATION WITH THE DATA SHEET TITLE:
<br /> CABLING VENDOR. THIS N WSTORE@STARBUCKS.COM OUP MAY BE CONTACTED AT: ELECTRICAL NOTES
<br /> AND LEGENDS
<br /> Schnackel SCALE:AS SHOWN
<br /> eNinem® SHEET NUMBER:
<br /> Newyork a Omaha m LoacAr4pks m Seattle m Hondtdu
<br /> 800-581-0963 wwwsdtmmLoom
<br /> 80 South Lake Avenue, Suite 640 Pasadena, CA 91101 E-0004
<br /> SE JOW: 181103