Laserfiche WebLink
SITE PLAN <br /> R7 11Clatlon # <br /> INv: 7z.z APP - On <br /> Received BY <br /> NOTE <br /> 1. EXISTING 6' CHAIN LINK FENCE ON EAST, SOUTH AND WEST PROPERTY LINES. <br /> EXISTING 4' WROUGHT IRON FENCE ON NORTH PROPERTY LIME. <br /> 2. STORM DRAIN: NATURAL DRAINAGE ULTIMATELY TO STORM PONDS. <br /> SCALE. 1" = 20' <br /> - Tim3. ALL BUILDINGS SHALL REQUIRE A BUILDING PERMIT AS INDICATED ON THE <br /> STATE ROUTE 12 CONDITIONS OF APPROVAL. <br /> F <br /> - - - ' <br /> 80 4 BUILDING PLAN BY <br /> OTHERS (DEFERRED SUBMITTA ) <br /> 5. PARKING STALLS ARE 9'X20'. PARALLEL STALLS ARE 9'X26'. <br /> 6. 100% LEACH FIELD REPLACEMENT AREA RESERVED PER EHD STANDARDS. AREA <br /> 131 <br /> TO BE RESTRICTED FROM DRIVING OR PARKING WHEN USED AS A LEACH FIELD. <br /> t _ s 7 <br /> SCREENING: ALL STORAGE MATERIALS AND RELATED ACTIVITIES, INCLUDING. <br /> 75.8 <br /> STORAGE AREAS FOR TRASH, SHALL BE SCREENED SO AS NOTTO BE VISIBLE <br /> RIM: 76.2 FROM ADJACENT PROPERTIES AND PUBLIC RIGHT-OF-WAY. SCREENING SHALL <br /> 76, 6D INV: 71.85 - - BE 6 TO 7 FEET IN HEIGHT. OUTSIDE STORAGE IS NOT PERMITTED IN FRONT <br /> - RIM: 75.2 YARDS, STREET SIDE YARDS, OR IN FRONT OF MAIN BUILDINGS. (DEVELOPMENT <br /> .a <br /> -- DEPRESSE INV: 70.8 TITLE SECTION 9-1022.4[6][2]} <br /> __-- � <br /> fr <br /> AREA (TYP.) <br /> j 248.9' <br /> RIM 75.5 + + + + + + + + + + + + + + + + + + <br /> 8. CULTURAL RESOURCES: IF IN THE COURSE OF DEVELOPMENT, <br /> CONCENTRATIONS OF PREHISTORIC OR HISTORIC PERIOD MATERIALS ARE <br /> 26 + + + + + + + + + <br /> INv: 70.2 RIM: 76'2 + + + + + + + - + + + + + + + + <br /> INV: 71.9 3�O 6F + + + + + + + + + ENCOUNTERED, ALL WORK IN THE VICINITY OF THE FIND SHALL HALT UNTIL <br /> AN ARCHAEOLOGIST CAN EVALUATE THE MATERIALS AND MAKE <br /> - - <br /> 6.3 + + + + + + + + + + + + + + + + + + + + + + + + RECOMMENDATIONS FOR FURTHER ACTION. IF HUMAN REMAINS ARE <br /> 1 + + ENCOUNTERED, ALL WORK SHALL HALT IN THE VICINITY AND THE COUNTY <br /> +�' � � o � o 0 0 0 o r�--•, o 0 0 � o LEG CORONER SHALL BE NOTICED IMMEDIATELY. AT THE SAME TIME, A QUALIFIED <br /> + +4 ARCHAEOLOGIST SHALL BE CONTACTED TO EVALUATE THE FINDS. IF HUMAN+ �� �, ! 1 I ! 3 I I ! I I r a + + + BURIALS ARE FOUND TO BE NATIVE AMERICAN ORIGIN, STEPS SHALL BE TAKEN <br /> + } i i I I I i I f ! i I f I I J I. + EX. EXISTING PURSUANT TO (SECTION 15064.5(E) OF GUIDELINES FOR CALIFORNIA <br /> + I I f I I I I I I I I + + + AC ASPHALT CONCRETE ENVIRONMENTAL QUALITY ACT.) <br /> + V I I I I I I I I + + A.P.N ASSESSOR'S PARCEL NUMBER <br /> + ` • + + + BLDG BUILDING 9. SOIL ENGINEER SHALL BE RETAINED TO PROVIDE OBSERVATION AND TESTING <br /> + <br /> STATE ROUTE 12 (EX.) 15-PARKING + + CF CUBIC FEET SERVICES DURING THE GRADING PHASE THAT INSPECTION AND TESTING REPORTS <br /> +C; 5.s STALLS TO REMAIN + + + F.F. FINISHED FLOOR SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT. <br /> LP LIGHT POLE <br /> o + + (P) 4-PARALLEL PARKING + - + P PROPOSED 10. CFC 507 FIRE PROTECTION WATER SUPPLY -FIRE FLOW AND HYDRANTS SHALL <br /> N Q � + 11 STALLS 9'X26' (TYP.) + + SF SQUARE FEET BE PROVIDED FOR THE PROPOSED PROJECT BY THE USE OF: CFC APPENDIX B. <br /> T W WATER <br /> J __J + + '4 + 11 . IF FIRE PROTECTION SYSTEMS ARE REQUIRED THEY SHALL BE INSTALLED <br /> J J l ACCORDING TO THE CFC, CHAPTER 9 AND THE APPROPRIATE STANDARDS AND <br /> w a + + + 9'X 3-PARALLEL STALLS + _ + + j 89.2 EXISTING SPOT GRADES GUIDES ADOPTED IN CHAPTER 35 OF THE CALIFORNIA BUILDING CODE AND THE <br /> � Z � 9'X20' (TYP.} (P} 2--PARALLEL PARKING 1 <br /> `� + -� 1 ADA PARKING STALL + CALIFORNIA ELECTRICAL CODE. <br /> (EX.} 4-PARKIN STALLS 9'X26' (TYP.) _ + - LEACH LINE <br /> m + + 10'X20' (TYP.) STALLS TO REMAIN <br /> EMIL ST SITE + + + + 12. CFC, SECTION 503 FIRE APPARATUS ACCESS ROADS - <br /> SHALL BE PROVIDED AS <br /> + + �!5.9 - + REQUIRED BY THIS SECTION. 503.1.2 - A SECONDARY ACCESS MAY BE <br /> + + I I _ + EXISTING FENCE REQUIRED. <br /> I ! I I I '. , 13. CFC, SECTION 906 PORTABLE FIRE EXTINGUISHERS - PROVIDE PORTABLE FIRE <br /> VlC1111�TY MAP I + + + + �, -� I ! I I ; ! ' ��.+ + + � <br /> NOT TO SCALE + + �, 17.2 ` -T - + + CENTER LINE EXTINGUISHERS A5 REQUIRED BY THIS SECTION. <br /> +' + � o _ J 77� -- 14. CFC, SECTION 505 KEY BOX - A KNOXC7$07C SHALL BE INSTALLED ACCORDING <br /> + + 2 � J - - -�7 RAMP 1 I 7.4 - -_, + + - - - w - - - EXISTING PARKING STALL TO THE LOCAL FIRE DEPARTMENT'S INSTRUCTIONS. MAKE APPLICATION F <br /> � � OR THE <br /> + + 77 - + + KEY BOX AT THE FIRE DISTRICT HAVING JURISDICTION OF THIS PROJECT. IF <br /> + + + 4- WATER VALVE THERE IS AN ELECTRONICALLY CONTROLLED ACCESS GATE AT THIS SITE A <br /> + + ` _ rL-7 r 9 + f KNOX®KEY SWITCH WILL ALSO BE REQUIRED. <br /> + + SEE NOTE 1 6'9 15. CFC, SECTION 5001 .3.3.1 PROPERTIES OF HAZARDOUS MATERIALS - A <br /> COMPLETE LIST OF HAZARDOUS MATERIALS USED AND OR STORED AT THIS SITE <br /> + + + + L. EX. SHED ® EXISTING CATCH BASIN EX. BLDG 36' 262 SF SHALL BE PROVIDED. <br /> + � + 57 T J,4g2 SF 76 EXISTING TREE <br /> WATER MAI $ 7 AO 16. A COMPLETE REVIEW, AT BUILDING PERMIT SUBMITTAL, WILL REQUIRE <br /> CONNECTION l + + 8G. 1 F.F. MATCH 76.8 COMPLIANCE WITH APPLICABLE CODES AND ORDINANCES. <br /> EXISTING BUSHES 17. CFC, SECTION 105 PERMITS: OPERATI A <br /> + <br /> ON L PERMITS) MAY 8E REQUIRED PRIOR <br /> � 5+ <br /> + + TO OCCUPANCY. <br /> 1 _74- $ L EXISTING AC 18. INSTALL ADDITIONAL ACCESSIBLE PARKING SIGNAGE. <br /> 67.1 <br /> + <br /> i+ + } �� PG so.a a RAMP 0 2 76.s -155' 76.4 77•� 19. EXISTING SANITARY FACILITIES WILL PROVIDE FOR THE PROPOSED FACILITY, PER <br /> 'I 5.8 - - -' EXISTING CON[. THE REQUIREMENTS OF CHAPTER 4 OF THE CALIFORNIA PLUMBING CODE. <br /> + •8 20. LANDSCAPING ACCOUNTS FOR 11% OF THE NET SITE AREA. <br /> 7 ,� 1 + APPROXIMATE LOCATION EPRESSED AREA + <br /> 27' �4Tcti J s.s FQR 1.00% REPLACEMENT 1 5' DEPTH + EXISTING LANDSCAPE 21. TOPOGRAPHY OF THE SITE IS RELATIVELY FLAT. <br /> 90 0 ° AREA FOR SEPTIC TANK <br /> 76.4 76.7 7fi.7 6.9 22. MOKELUMNE RIVER IS APPROXIMATELY 1 MILE FROM THE PROPERTY BOUNDARY. <br /> I 7 d <br /> 7fi.D ° 3 J PROPOSED CON[. <br /> CONSTRUCTION NOTE51K a PROPOSED GRAVEL �a�ES ' <br /> 1 y <br /> EX, W FAUCET �`;Q•GE y��� <br /> 1 INSTALL TRASH ENCLOSURE. SEE SHEET 3 FOR DETAILS, 4 <br /> 2 INSTALL ACCESSIBLE ROUTE TO PROPOSED BUILDING. FO' I -7-7.0 ~ <br /> ��-� GRADE TO DRAIN <br /> 7fi.4 ROCK <br /> 3 INSTALL ADDITIONAL ACCESSIBLE PARKING SIGNAGE. SEE 75.7 l <br /> 76.2 78.4 7 76. 76.9 f 7 .5 - y 1 l <br /> 77.6 �'`J� �� <br /> COVER SHEET FOR DETAILS. 16.4 1 <br /> 4@. SAWCUT 29 LF OF CONCRETE. 0 PROPOSED BLDG 5CY <br /> 5 REMOVE 240 SF OF CONCRETE. <br /> 11 <br /> f <br /> 5 INSTALL FIRE HYDRANT. SEE CFC 507 APPENDIX B. ' ,700 SF ° EX. SEPTIC <br /> 77.3 F.F. <br /> REMOVE LIGHT POLE. < ' <br /> - � <br /> 76., 7C`2 D 76,4 76.2 76.6 76.2 $ 76 DILLON & MURPHY <br /> 7fi.4 r 6,7 ENGINEERING <br /> 1Ex. LP 847 N. CLUFF AVENUE <br /> 6.3 SUITE A-2,D I L LO N & MURPHY (209) 334651[361, CA 95240 <br /> EX. LP <br /> 2 0' 6.3 1 o E N G I N E E R I N G <br /> I M P RCV M ENT_ NOTES 76 75.s 6 3 6.8 7 .6 76.5 76.3 76.5 76.9 <br /> X6.0 LENZI INC. <br /> 1. PARKING: EXISTING PARKING STALL COUNT: 150' <br /> NEIN STORAGE BUILDING <br /> 22 STANDARD STALLS 6645 CF <br /> 1 ACCESSIBLE STALLS 20' <br /> 23 STALLS TOTAL ��� 25 �. ����. a IMPROVEMENT AND SITE PLAN <br /> 9150 E. STATE ROUTE 12 N <br /> PROPOSED TOTAL PARKING STALL COUNT: 76.0 _ _ _ _ v Know what's below. ry <br /> 28 STANDARD STALLS 76., - - - 767 f 76.6 77 76.6 <br /> i 76.8 6•, CaII before you dig. LODI, CALIFORNIA a <br /> 2 ACCESSIBLE STALLS 248.9' 76.7 <br /> AUGUST, 2021 <br /> 30 STALLS TOTAL <br /> Q <br /> RADE SWALE TO DRAIN PROPOSE REV. NO. DESCRIPTION DATE SCALE: 1"=2O' BENCH MARK: JS1106 EL: 79.00 SHEET <br /> POND DESCRIPTION: BRASS DISK "S1106" <br /> DRAWN BY: TH 1960 AT NORTHWEST PORTION OF 2 <br /> DESIGNED BY: HIGHWAY & LOCUST TREE RD. OF 3 SHEETS o <br /> INTERSECTION. SW COR. TOP OF <br /> 71 <br /> CHECKED BY: CONC. CATCH BASIN. NGS <br /> »JS1400» SOB NQ. N <br /> a <br /> AS BUILT BY: DATUM: NAVD 88 2110 N <br /> N <br />