My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2021
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ARTHUR
>
23534
>
2800 - Aboveground Petroleum Storage Program
>
PR0524264
>
COMPLIANCE INFO_2021
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2022 9:49:57 AM
Creation date
10/5/2021 9:41:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2021
RECORD_ID
PR0524264
PE
2832
FACILITY_ID
FA0006141
FACILITY_NAME
A L POWELL TRUCKING
STREET_NUMBER
23534
Direction
E
STREET_NAME
ARTHUR
STREET_TYPE
RD
City
ESCALON
Zip
95320
APN
22903010
CURRENT_STATUS
01
SITE_LOCATION
23534 E ARTHUR RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J 0 A Q I I I Irl Environmental Health Department <br /> COUNT <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> A L POWELL TRUCKING 23534 E ARTHUR RD, ESCALON October 04, 2021 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 715 CFR 112.8(c)(8), 25270.4.5(a)Failed to have a high level monitoring and to engineer or update containers to avoid <br /> discharge. <br /> OBSERVATION: Page 40 of the SPCC Plans states all tanks are equipped with manual leak detectors. Manual leak <br /> detectors were not observed on the 250 gallon used oil tank, 250 gallon gasoline tank, 12,000 gallon diesel tank, <br /> and 120 gallon automatic transition fluid tank. <br /> REGULATION GUIDANCE: (c)(8)Engineer or update each container installation in accordance with good <br /> engineering practice to avoid discharges.You must provide at least one of the following devices: <br /> (i) High liquid level alarms with an audible or visual signal at a constantly attended operation or surveillance station. <br /> In smaller facilities, an audible air vent may suffice. <br /> (ii)High liquid level pump cutoff devices set to stop the flow at a predetermined container content level. <br /> (iii)Direct audible or code signal communication between the container gauger and the pumping station. <br /> (iv)A fast response system for determining the liquid level of each bulk storage container such as digital computers, <br /> telepulse, or direct vision gauges. If you use this alternative, a person must be present to monitor gauges and the <br /> overall filling of bulk storage containers. <br /> CORRECTIVE ACTION: Immediately install an approved liquid level sensing device on 12,000 gallon diesel tank, <br /> 250 used oil, 250 gasoline tank, and 120 gallon automatic transition fluid tank in accordance with CFR 112.8 and <br /> implement necessary procedures to ensure that this device is fully functional and in use at all times during tank's <br /> filling operations, provide proof of correction to the EHD. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 11/4/2021. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> ($152). To schedule an appointment, please call (209)468-3420. <br /> The following was observed during this inspection: <br /> - 12,000 gallon diesel fuel <br /> -250 gallon gasoline <br /> -250 gallon used oil <br /> -250 gallon kerosene <br /> - 120 gallon automatic transition fluid <br /> - 100 gallon fuel tank <br /> Reviewed SPCC Plans. <br /> The following was provided during this inspection: Schedule of free CUPA classes, Return to Compliance <br /> Certifications. <br /> FA0006141 PR0524264 SCO01 10/04/2021 <br /> EHD 28-01 Rev.9/16/2020 Page 9 of 10 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.