My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SU0014459
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
K
>
KASSON
>
28524
>
2600 - Land Use Program
>
PA-2100209
>
SU0014459
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2022 4:43:58 PM
Creation date
10/6/2021 11:44:32 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2600 - Land Use Program
RECORD_ID
SU0014459
PE
2631
FACILITY_NAME
PA-2100209
STREET_NUMBER
28524
Direction
S
STREET_NAME
KASSON
STREET_TYPE
RD
City
TRACY
Zip
95304-
APN
24138002
ENTERED_DATE
10/5/2021 12:00:00 AM
SITE_LOCATION
28524 S KASSON RD
RECEIVED_DATE
1/6/2022 12:00:00 AM
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\tsok
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
d. PARKING: Off-street parking shall be provided and comply with the following: <br /> 1. All parking spaces, driveways, and maneuvering areas shall be surfaced and permanently <br /> maintained with base material of appropriate depth and asphalt concrete or Portland cement <br /> concrete to provide a durable,dust free surface.Bumper guards shall be provided when necessary <br /> to protect adjacent structures or properties. (Development Title Section 9-1015.5[e]) <br /> 2. A minimum of 2 parking spaces shall be provided for the manure digester facility. (Development <br /> Title Section 9-1015.9) <br /> 3. Parking spaces for persons with disability shall be provided as required by Chapters 11 A and 11 B <br /> of the California Building Code. <br /> 4. Each parking stall shall be an unobstructed rectangle, minimum 9 feet wide and 20 feet long. <br /> (Development Title Section 9-1015.5[b]) <br /> e. ACCESS AND CIRCULATION: The following requirements apply and shall be shown on the Site <br /> Plan: <br /> 1. Access driveways shall have a width of no less than 25 feet for two-way aisles and 16 feet for <br /> one-way aisles, except that in no case shall driveways designated as fire department access be <br /> less than 20 feet wide. (Development Title Section 9-1015.5[h][1]) <br /> f. LIGHTING: Lighting shall be provided and comply with the following: <br /> 1. If the parking area is to be used at night, parking lot lighting shall be installed. (Development <br /> Title Section 9-1015.5[g]) <br /> 2. Any lighting shall be designed to confine direct rays to the premises. No spillover beyond the <br /> property lines shall be permitted except onto public thoroughfares, provided, however, that <br /> such light shall not cause a hazard to motorists. (Development Title Section 9-1015.5[g][4]) <br /> g. MITIGATION MONITORING REPORTING PLAN:A Mitigation Monitoring Reporting Plan (MMRP) <br /> dated February 23, 2022 is approved with this project. Mitigation measures contained in the MMRP <br /> shall be satisfied prior to issuance of any building permits. <br /> h. BUILDING CODE REQUIREMENTS: The following California Building Code (CBC) and San <br /> Joaquin County Ordinance requirements will be applicable to the proposed project. The following <br /> conditions shall be addressed prior to submittal of a building permit application to the Building <br /> Inspection Division: <br /> 1. A building permit for each separate structure or building is required. Submit plans, <br /> Specifications and supporting calculations, prepared by a Registered Design Professional <br /> (architect or engineer) for each structure or building, showing compliance with the applicable <br /> California Building Standards Code in effect on the application date for the building permit(s). <br /> Plans for the different buildings or structures may be combined into a single set of construction <br /> documents. (Please visit https://www.sjgov.org/commdev for building permit checklist(s) and <br /> application forms. <br /> 2. A grading permit will be required for this project. Submit plans and grading calculations, <br /> including a statement of the estimated quantities of excavation and fill, prepared by a <br /> Registered Design Professional. The grading plan shall show the existing grade and finished <br /> grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and <br /> show in detail that it complies with the requirements of the code. The plans shall show the <br /> existing grade on adjoining properties in sufficient detail to identify how grade changes will <br /> conform to the requirements of the code. <br /> PA-2100209—Conditions of Approval 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.