Laserfiche WebLink
(-)EXISTING PANEL >, ,9 <br /> LOCATION HA! TITLE 24 CATEGORY: C U I1._k.:T 5 <br /> ELECTRICAL LEGEND <br /> (e)MAIN SERVICE "MS's TOTAL KVA : 28 CONNECT AMPS: 67.4A <br /> ELECTRICAL LEGEND — -- — MOUNTING FLUSH VOLTAGE : 120;"240V, 30, 4W <br /> DRAFTING NOTATIONS ELECTRICAL POWER (e)120/24OV, 30, 4W BUS BUSSING : 20-0A ❑ MCB E] MLO FEEDER ❑ SEE ONE LINE DIAGRAM <br /> M : <br /> N## AIC 10,000 ED EXISTING <br /> #KEY NOTE, SEE SCHEDULE .r f ALL LINE VOLTAGE WIRING IN CONDUIT, SEE GENERAL NOTES DESCRIPTION LOAD <br /> TICKS = OF#12 WIRE, SHORT= HOT, LONG = NEUTRAL, DOT=GROUND, M BRKR BRKR LOAD DESCRIPTION <br /> N## EQUIPMENT TAG, SEE SCHEDULE <br /> UNLESS NOTED OTHERWISE (e)30 1 A 2 (e)1 ,5 a -,52 fe)4�J�LK Ifd '1 F;GE fYAFOR <br /> 120V OUTLET, +18"TO BOTTOM OF BOX 3 <br /> (e)200 (e)100 (e)A. 1920 3 B <br /> - � � <br /> REFERENCE TO A DETAIL VIEW"A"ON SHEET E-2 S= SIGN 2 5 C W M B <br /> E2 F = FLOOR <br /> (e)"O 7 A 40 8160 DISH WASHER <br /> GF! = GROUND FAULT INTERUPTER g B 2 ARCHITECTS <br /> �' — ''(e)AOf��2 1 � <br /> NEW ELECTRICAL COUNTER OUTLET <br /> -- EXISTING ELECTRICAL OR DEMOLISHED WHERE NOTED <br /> 11 C 12 <br /> QUADRUPLEX OUTLET (e) 0) 13 A (6=) }Q <br /> (e) (E) EXISTING DEVICE, TO REMAIN IN OPERATION WM'v' R 1300 113 X60'HALF SWITCHEp OUTLETS 155757 Pacific Avenue <br /> 5 <br /> (r) (R) REMOVE DEVICE, KEEP REMAINDER OF CIRCUIT IN OPERATION ' ET 17 C .3 Suite 226 <br /> OUTLETS ON EMERGENCY SYSTEMS (e)ROOF G!-CI OJ,�r! 180 (e)20/1 19 A (e)20/ ; 1044- (e)SODA DISPENSER Stockton, CA 95207 <br /> (RR) REMOVE, RELOCATE AND RECONNECT DEVICE ON EXISTING CIRCUIT, EXTEND CIRCUIT ke)v )F F MAKER 3096 (I - --' <br /> 211.13 (e)20,-"' 1350 ( )ICE:MAKER <br /> COMMUNICATIONS 2 231 C 2 2000 L Street <br /> ~ TELEPHONE BACKBOARD, PROVIDE#8 GND TO SERVICE GROUND REFRIGERATOR 396 20/1 A )2 1 3 r Suite 125 <br /> / 25 (e;�0/1 800 e DISE kAV C:�S�, CCM,` QUTL.�:1� <br /> P° COMMUNICATIONS OUTLET, PHONE 8,DATA (e)PANEL (e)PANEL27 B 20/1 816 GLASS CHILLER Sacramento, CA 95811 <br /> C <br /> , 1, 29 <br /> PHONE ONLY OUTLET, PREWIRED WITH CAT 5e CABLE A "g" FANS 480 20/1 31 A 32 20/1 500 N OUTLET T 209.944.9110 <br /> BAR OUTLET'S 360 20/1 33 B 20/1 500 TV OUTLET <br /> DATA ONLY OUTLET JACK, PREWIRED WITH CAT 6 CABLE F 209.944.5711II'llJarC111teCtS.Cpm <br /> ONE LINE DIAGRAM WWW.W35 C <br /> C_ _j BUS 1 SWITCHBOARD 5413 �) CIRCUIT BREAKER 50 AMP RATED, 3 POLE <br /> MOUNTING HEIGHTS FINISHED CEILING 37 A <br /> GFI = GROUND FAULT INTERRUPTER AUDIBLE ONELINA DIAGRAM 39B <br /> 41 C <br /> AFCI =AFIRE ALARM APPLIANCE <br /> PANEL NOT LESS THEN 90"AFF OR AT SCALE: N.T.5. 1421 <br /> RC FAULT CIRCUIT INTERRUPTER LEAST 6"BELOW CEILING 1 0�08 VA TOTAL 185C,8 <br /> - GROUND �' DISCONNECT, RATED TO POWER SOURCE <br /> ( "C" SPNC FR L.EG <br /> r VOLTAGE AND AMPERAGE RATING FOR FUSE NOT LESS THAN 80"AFF MIN, <br /> VISUAL APPLIANCE TO BE <br /> O METER OR AS NOTED AND NOT MORE THAN 96"AFF <br /> 12"TYPICAL TO BOTTOM <br /> 19 r�99 <br /> DIMMING ROOM <br /> CR#= CONTROL RELAY i <br /> CR1 RELAY- FERE ALARM MANUAL CONTROLLER WITH <br /> 0*� EXISTING PANEL <br /> TDR=TIME BELAY RELAY SYSTEMS FURNITURE PULL STATION SHALL NOT CATS INPUTS FOR LOCATION : HALL TITLE 24 CATEGORY: OUTLETS <br /> REQUIRE"TIGHT GRASPING, LIGHT SWITCHES, TOTAL KVA 1 CONNECT AMPS: <br /> M = MOTOR STARTER CONNECTIONS+15"TO MOTION SENSORS, 4y�� 6A <br /> PINCHING OR TWISTING OF , <br /> CONTACTOR RELAY BOTTOM of BO THE WRIST LINE VOLTAGE DAY LIGHT PHOTOCELL MOUNTING FLUSH VOLTAGE 120/24OV, 10 4W <br /> ETM= ELAPSE TIME METER INPUT BUSSING 100A ❑ MCB ® MLO FEEDER F-1 SEE ONE LINE DIAGRAM— <br /> FIXTURE NOTATIONS: +15 TO BOTTOM ® EXISTING <br /> ❑ LINEAR FIXTURE A,(b),C-12 FIXTURE TYPE"A", SWITCH "b", CIRCUIT C-12 OF BOX OR WALL PHONE DESCRIPTION LOAD BRKR BRKR LOAD DESCRIPTION Michael's Pizza <br /> • SQUARE= RECESSED LIGHT SWITCHES <br /> )COP�VENlENCE OUTLET 360 (e)20/1 1 A (e)20/1 X1-`18 (e)LIGHTfNG Remodel <br /> • CIRCLE=SURFACE (e <br /> D DD 4$"TO TOP <br /> OF BOX (e)CONVENIENCE OUTLET 720 (e)20111 3 B 1-544. (e)LIGHTING <br /> ® O DOWNLIGHT, SQUARE = RECESSED FINISHED FLOOR TO SECOND TO SECOND ) _!. . ) t 2300 W Alpine Ave <br /> SWITCH SENSOR {.,fk �?Cf,. .�I_.IC k.:F 74*I (e)20/1 5 C 1800 (e)I'A:)I:)I....1_ {-_ANS Stockton, CA 95204 <br /> �, RE.FRI01-_FZA 10 F? 14-40 (e)20/1 A ,200 <br /> Q-I WALL MOUNT 7 (e,(,ONVE.NfENCk:. 01,11]...i::._f <br /> ® CEILING EXHAUST FAN <br /> (e)SDACE (e)20/1 g B 720 (e)HOOD EXHAUST <br /> (e) HAVED, ICE 1440 (e)20/1 11 C BAR LfG iT�a <br /> a.o POLE MOUNT AREA LIGHT (e)ESPRESSO 21 C,,C3 (e) ?L� 13 A (e)li3PAC`1 ONE LINE DIAGRAM, <br /> LEGEND PANEL <br /> ( �)COFF EE GRIND R 960 (e)2.:./�1 17 C SCHEDULES, & ELECTRICAL <br /> EMERGENCY LIGHTING 1` DETAILS <br /> (c-)S ACS WC <br /> A <br /> EXIT SIGN WITH 90 MIN BATTERY BACKUP LINE VOLTAGE f e)� 'ACS B <br /> CONTROL &WALL MOUNT EMERGENCY LIGHT WITH 90 MIN BATTERY BACK 0-10V DIMMER (e)SRACE 241 <br /> CONTROL25A <br /> Q-I EXTERIOR LANDING EMERGENCY LIGHT. CONNECT <br /> TO INTERIOR EXIT SIGN FOR POWER. WALL MOUNT CEILING CEILING 27 B <br /> 281 <br /> 0 H 0 FIXTURES WITH INTEGRAL EMERGENCY BALLAST SWITCH WITH OCCUPANCY PHOTOELECTRIC 29 CONANDFIZ4 SEER SENSOR SENSOR 31 A 30 <br /> LOWER CONTROL <br /> BASIC LIGHTING CONTROLS <br /> 35 C <br /> 371A .3 <br /> LIGHT SWITCH, +48"TO TOP OF BOX <br /> 39 B <br /> D= DIMMER C <br /> • 3= 3WAY 4 <br /> • P= PILOT SWITCH 7824 VA TOTAL 5512 <br /> • os= LINE VOLTAGE OCCUPANCY SENSOR <br /> • T=TIMER <br /> • VS =VACANCY SENSOR <br /> ® WALL MOUNT OCCUPANCY SENSOR (LINE VOLTAGE) <br /> 0-10V DIMMING LIGHTING CONTROLS <br /> TITLE 24 LIGHTING CONTROLS <br /> LIGHT FIXTURES <br /> LIGHT SWITCH <br /> COMPONENTS OF DIMMING ROOM CONTROLLER LINE VOLTAGE (HOT, SWITCH HOT, NEUTRAL, GROUND & 3#14 DIMMING) <br /> LIGHTING CONTROL DETAIL —D� D-1 DV CONTROL CABLE (3#14) <br /> US= LOW VOLTAGE OCCUPANCY SENSOR(CAT 5 OR AS REQUIRED) PUBLISH HISTORY: <br /> • DRC = DIMMING ROOM CONTROLLER —N-- CAT-5 CONTROL CABLE <br /> • PE= LOW VOLTAGE DIMMING PHOTOCELL (CAT 5 OR AS REQUIRED) SCALE: N.T.S. �o. DATE REVISION <br /> D = LOW VOLTAGE DIMMER (CAT 5 OR AS REQUIRED) <br /> 'r = PLUG LOAD CONTROLLER <br /> US CEILING MOUNT OCCUPANCY SENSOR <br /> v 08.19.20 PERMIT SET <br /> • ADR=AUTOMATIC DEMAND RESPOSNE(FOR BUILDINGS OVER 10,000 SF) PC PHOTOCELL <br /> o NOTES: $D DIMMING SWITCH <br /> I 1. FOR SUBMITTAL INCLUDE FACTORY CONTROL DRAWINGS. dre DIMMING ROOM CONTROLLER <br /> ® OUTLET RELAY 20A RATED <br /> 0 2. CONDUCT A CONTROLS PRE-CONSTRUCTION MEETING WITH CONTROLS <br /> STARTUP TEAM. PROVIDE AGENDA AND ATTENDEES AS A SUBMITTAL, INCLUDEX U HT� U <br /> NOTES:N DEVICE l.D. TAGS, PROGRAMMING, CABLE ROUTING, PROGRAM AND TIME +E •J S D <br /> ai <br /> SCHEDULES AND DATE OF PROGRAMMING AND TESTING, TYPE JAPS1 W LloP DESCRIPTION F MANUFACTURER'S NO. LOAD 1. FOR SUBMITTAL INCLUDE FACTORY CONTROL DRAWINGS. <br /> 6 RECESSED DOWN LIGHT LITHONIA 2CONDUCT A CONTROLS <br /> rn 3. CONTRACTOR TO HAVE SYSTEM FACTORY SUPPORT FOR START UP, . PRE—CONSTRUCTION MEETING WITH CONTROLS STARTUP <br /> a PROGRAMMING AND COMMISSIONING.VERIFY OPERATIONAL HOURS WITH OWNER A LED #LDN6-40/10—L06—MVOLT—EZ 1 TAGS, PROGRAMMING,AGENDA <br /> NDAABLE ATTENDEES <br /> AS A SUBMITTAL. INCLUDE DEVICE I.D. <br /> PRIOR TO COMMISSIONING. 1 1 GRAM AND TIME SCHEDULES AND DATE <br /> .o OF PROGRAMMING AND TESTING. <br /> `" BAR AREA PENDENT HI LITE 3. CONTRACTOR TO HAVE SYSTEM FACTORY SUPPORT FOR START UP, PROGRAMMING <br /> AND COMMISSIONING. VERIFY OPERATIONAL HOURS WITH OWNER PRIOR TO <br /> � B 1 100 VERIFY MOUNTING HEIGHT H 2040 <br /> IN FIELD 100 COMMISSIONING. <br /> v <br /> N <br /> 'a <br /> m 65" CEILING FAN MINKA AIR <br /> t FAN — — EXTREME H2O COAL WET FAN _ <br /> '0 #56D82 WMB PROJECT; <br /> E COMBINATION EXIT SIGN/ LITHONIA 20-030 <br /> o ERESS MGT UNIT, 90 #LHQM LED R HO SD <br /> N BATTERY <br /> I <br /> BACKUP — <br /> o WALL MOUNT EMERGENCY LITHONIA <br /> EGRESS LIGHT UNIT, 90 #ELM2L <br /> MIN BATTERY BACKUP E O.2 <br /> C — <br /> N <br /> Y REMOTE EMERGENCY LITHONIA eR°�Ess'O� <br /> L;jl� EXTERIOR LIGHT POWERED AFF OELR DWHGXD WT �51zFeatheri?iverorF.stoo<t©n.cAsszl9 <br /> 209-478-8270 f www.hcs-eng.corn \v� %y�c <br /> . HCS. Z <br /> Richard C.Smith.PE richard@hcs-en .com No. E14303 <br /> � BY4e - <br /> Engineering g xp. 6-3p-21 <br /> ❑Bhupendra Patel,PE Bhupendra@hcs-en opat : !)ohn117/4 50 ears ©Elizabeth Agdar elizabeffighcs-eng.c <br /> y <br /> PROJECT#2020.222 <br /> 811112020 7:06;47 AM Copyright WMB,Inc. <br />