My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
A
>
ALPINE
>
2300
>
1600 - Food Program
>
PR0160469
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2021 11:46:25 AM
Creation date
10/7/2021 2:17:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0160469
PE
1625
FACILITY_ID
FA0001695
FACILITY_NAME
Michael's New York Style Pizza, Inc
STREET_NUMBER
2300
Direction
W
STREET_NAME
ALPINE
STREET_TYPE
Ave
City
Stockton
Zip
95204
APN
111090190222
CURRENT_STATUS
01
SITE_LOCATION
2300 W Alpine Ave
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLUMBING FIXTURE SCHEDULE PLUMBING LEGEND <br /> MARK MAKE & MODEL DESCRIPTION TRIMREMARKS CAL GREEN SPECIFIED SYMBOL DESCRIPTION <br /> E A DD C GP DE FIXpU EPM <br /> FS-1 ZURN 12"02"x6" WHITE ACID RESISTING PORCELAIN TOP —CW COLD WATER LINE <br /> SQUARE SCORIATED <br /> Z-1900 FLOOR SINK - —HW HOT WATER LINE <br /> ZURN ---SS SANITARY SEWER LINE <br /> TOP WITH VANDAL FD-1 ZN_415-S SQUARE FLOOR w1 T_-1 WATERLESS NICKEL BRONZE HEEL-PROOF <br /> PROOF SCREW TRAP MER STRAINER --HV HORIZONTAL VENT <br /> MAY EXTEND ASA Tp_ --RWL RAIN WATER LEADER1 THE SURE SEAL CONDENSATE DRAIN RAP SEALER -- <br /> WASTE OR VENT 552009V —CD— <br /> GLEAN OUT <br /> ZURN <br /> WALL PLAN FINISHED FLOOR FCO FLOOR CLEANOUT SEE SPECIFICATIONS FOR TOP fl— WALL CLEAN OUT <br /> ZN-7400 —FCO FLOOR CLEAN OUT <br /> CHROME WALLCOVER ADJUSTABLE LEVEL ZURN --—YC0 YARD CLEAN OUT TO GRADE p p <br /> & SCREW 4' a : CONTROL WCO ZS-1446 WALL CLEANOUT SEE SPECIFICATIONS FOR TOP ® FLOOR DRAIN WM B <br /> d FLOOR SINK <br /> PLUGGED OU WHA-7 WATTS I SHER PROVIDE ELMDOR DW-SS-CL 12 X12 ® TRAP PRIMER <br /> W/ CLEANOUT FLOOR LINE '4, �* MEMBRANE N0. 05H WWATER HAMMEQ ASHING MACHINE FOR SIZE STAINLESS STEEL ACCESS PANEL SHB HOSE BIBB ARCHITECTS <br /> SEE SPECIFICATIONS 7 --Do-- GATE VALVE <br /> FOR ADDITIONAL SOV SHUT OFF VALVE <br /> ' 2019 COMMERCIAL CALIFORNIABALANCING VALVE`- INFORMATION � GAS COCK <br /> • 's� ... ,• • '' ' • •.• .�, • _—_ �� , ' 5757 Pacific Avenue <br /> • e°• • GREEN <br /> � GLOVE VALVE Suite 226 <br /> 4.' CAST IRON RISER CODE PRESSURE REDUCING VALVE (PRV) <br /> (BALANCE OF PIPING <br /> -- CIRCUIT SETTER BALANCING VALVE Stockton, CA 95207 <br /> 1/8" C I BEND SAME AS CLEANOUT TO GRADE <br /> ' � CODE REQUIREMENTS LOCATION FOUND CHECK VALVE <br /> EXPANSION JOINT <br /> +� 5.303,3.4 FAUCETS AND FOUNTAINS. V V <br /> FH o WATER HAMMER ARRESTER WITH SIZE 2000 L Street <br /> REFER TO PLUMBING FIXTURE V, V , VTR VENT, VENT RISER, VENT THRU ROOF Suite 125 <br /> SCHEDULE L W R SHEET FOR SS, SSD SEWER, SANITARY SEWER DROP Sacramento, CA 95811 <br /> 5.303.3.4.1 NONRESIDENTIAL LAVATORY FAUCETS. LAVATORY FAUCETS SHALL REQUIRED FLOW RATES. <br /> HAVE A MAXIMUM FLOW RATE OF NOT MORE THAN 0,5 GALLONS CW, D, R COLD WATER (DROP)(RISER) <br /> PER MINUTE AT 60 PSI. HW, D, R HW SUPPLY (DROP)(RISER) <br /> 5-LCTION HWR HOT WATER RETURN T 209.944.9110 <br /> 5.303.3.4.2 KITCHEN FAUCETS. KITCHEN FAUCETS SHALL HAVE A MAXIMUM THW TEMPERED HOT WATER F 209.944.5711 <br /> FLOW RATE OF NOT MORE THAN 1.8 GALLONS PER MINUTE AT G NATURAL GAS LOW PRESSURE WWW,Wmbarchitects.com <br /> 60 PSI. KITCHEN FAUCETS MAY TEMPORARILY INCREASE THE MPG MEDIUM PRESSURE GAS <br /> FLOW ABOVE THE MAXIMUM RATE, BUT NOT TO EXCEED 2.2 HPG HIGH PRESSURE GAS <br /> GALLONS PER MINUTE AT 60 PSI,AND MUST DEFAULT TO A LPG PROPANE GAS <br /> MAXIMUM FLOW RATE OF 1.8 GALLONS PER MINUTE AT 60 PSI. CA COMPRESSED AIR <br /> DL DRAIN LINE <br /> 5.303,4.4.3 WASH FOUNTAINS. WASH FOUNTAINS SHALL HAVE A MAXIMUM DS DOWN SPOUT <br /> RD ROOF DRAIN <br /> FLOW RATE OF NOT MORE THAN 1.8 GALLONS PER MINUTE120 AD AREA DRAIN <br /> [RIM SPACE(INCHES)AT 60 PSI). AC ABOVE CEILING <br /> WALL CLEAHOUT ��OO� CLEANOUT 5.3o BG BELOW GRADE <br /> 3.4,4.4 METERING FAUCETS. METERING FAUCETS SHALL NOT DELIVER MV MIXING VALVE <br /> D n NOT TO SCALE . 0 GALLONS PER CYCLE. WC <br /> (^� <br /> DETML NOT TO SCALE MORE THAN2 <br /> � WATER CLOSET <br /> UR URINAL <br /> 5.303.4.4.5 METERING FAUCETS FOR WASH FOUNTAINS. METERING FAUCETS LAV LAVATORY <br /> FOR WASH FOUNTAINS SHALL HAVE A MAXIMUM FLOW RATE OF S SINK <br /> NOT MORE THAN 0.20 GALLONS PER CYCLE/20[RIM SPACE(INCHES) SS SERVICE SINK <br /> TYPICAL THREADED ROD HANGER AT 60 PSI]. WM WASHING MACHINE <br /> SUPPORTS SEE HANGER SCHEDULE DF DRINKING FOUNTAIN <br /> & OSHPD ORE-APPROVAL NO. NOTE: WHERE COMPLYING FAUCETS ARE UNAVAILABLE, GD GARGABE DISPOSAL <br /> OPM-0052-13. NOTE: AERATORS OR OTHER MEANS MAY BE USED TO ACHIEVE F FIRE PROTECTION LINE <br /> PRIOR TO SETTING FLOOR SINK, REDUCTION. FHC FIRE HOSE CABINET Michael's Pizza <br /> PIPE HANGER SCHEDULE PLUMBING CONTRACTOR TO FHS FIRE HOSE STANDPIPE <br /> PIPE SIZE HANGER Ro BOLT COORDINATE WITH LOCAL HEALTH INV. INVERT ELEVATION Remodel <br /> > THRU Y4 Y4" V4 DEPARTMENT TO CONFIRM EXACT FG FINISHED GARDE <br /> 1 THRU 01" _- �" ��� REQUIREMENTS WHETHER FLOOR SINK ������� ��11VlNE��I® F/G FUEL GAS <br /> 2 THRU 2V �y" IS TO BE FLUSH OR RAISED 1" ABOVE CONNECTION N SIZE P.O.C. POINT OF CONNECTION 2300WAIpi�eAve <br /> 3 '/z '� TYPICAL TRANSVERSE & LONGITUDINAL FINISHED SURFACE. wasTE COLD wnr�t HOT wnTm AP ACCESS PANEL Stockton, CA 95204 <br /> FIXTURE SYM BRMCH TRAP VENT Bwwow ovn.Er BW oun sr Cf CAST IRON <br /> ACING PER OSHPD PRE-APPROVAL FLOOR DRAIN 3" FD 2",3" 3" 2" - - - - - <br /> - OPM-0052-13. VC VITRIFIED CLAY <br /> HANGER ROD- SEE INSULATION SUPPORT FLOOR SINK FS 3" 3" 2" CENTER LINE <br /> SCHED. FOR SIZE H�R HEADER <br /> HOT WATER FINISHED DRAIN PIPE DN DOWN PLUMBING <br /> MBH THOUSANDS OF BTU PER HOUR SCHEDULES <br /> WROUGHT STEEL WALL NIPC NOT IN PLUMBING CONTRACT <br /> CEEVIS HANGER- ADJUSTABLE UNDER PLUMBING CO & DETAILS <br /> SEE SPECS. FOR BAND HANGER- CONTRACT TYPE SEE SPECS. FOR V2" SINK GRATE D.L. DEVELOPED LENGTH <br /> TYPE 25% OPEN <br /> GAS& CONDENSATE ALVANIZED SHIELD <br /> PIPING SIMILAR AT INSULATION 7, FINISH GRADE KITCHEN-PLUMBING FIXTURE SCHEDULE <br /> a 4.. . e' PLUM SUPPLY INSTALL WATER WASTE WL5 ISLS GAS <br /> PIPE SUPPQRT NOTES: ' NO. DESCRIPTION HGT ® HGT C� HGT ® REMARKS <br /> • QTY BY BYCW Wi 10 HA1 WALL WALL VENT x 00 SIZE WALL <br /> GAS PIPES: 4 . a p a , <br /> ,•4• O HAND SINK 1 SUPREME P.C. 3 4" 3 4" -- -- -- 1-1 2" -- <br /> PIPE 1"0 OR LARGER SHALL HAVE TRANSVERSE BRACING ' <br /> a METAL / / / -- -- -- -- SL-HS-15 <br /> ® 14' O.C. (MAX)& LONGITUDINAL BRACING CSD 20' O.C. 2 DISH WASHER 1 1EURODIB P.G. -- -- __ " __ __(MAX) PIPES LESS THAN 1"0 NEED NO BRACING. -- 1 7-1/4 -- -- -- F92EKDPS <br /> OTHER PIPES: O'/z" DUMP SINK 1 OMCAN P.C. 3/4" 3/4„ --- 1-i/2" -- -- -_ -_ -- 43761 <br /> PIPE 2O OR LARGER SHALL HAVE TRANSVERSE BRACING SEDIMENT BUCKET <br /> ® 16' O.C. (MAX) & LONGITUDINAL BRACING ® 32' O.C. (MAX) 4 DRAIN BOARD 1 LACROSSE P.C. --- -- <br /> TYPICAL _ _ <br /> PIPES LESS THAN 21/2" NEED NO BRACING. Oi" SDW36 <br /> ALL PIPES�,� 5O ICE BIN 1 SUPREME P C " �_ _-_ <br /> FOR PIPES WHERE THE DISTANCE OF THE HANGER (FROM TOP METAL -- -- -� 7 - SLI-12-36-7 <br /> OF PIPE TO BOTTOM OF SUPPORT) IS LESS THAN 12", NO SEISMIC TURBO _ _ <br /> RESTRAINTS REQUIRED WHEN SPECIFIC CONDITIONS ARE MET PER _- __ <br /> O REFRIGERATOR 7 AIR P.C. - -- -- --- -- -- TBB-4SG-N <br /> 1-6 OF OSHPD PRE-APPROVAL N0. OPM-0052-13. -- - <br /> PIPE WQLIVGE� IFUNDR SINK O GLASS CHILLERS 1 PERLICK P.C. -- -- -- -- -- --- -- -- -- -- FR36 <br /> DETAIL NOT TO SCALE � dd I, NOTES: <br /> DEINUL NOT TO SCALE �.r i. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE <br /> FOR ROUGH-IN AND FINAL CONNECTIONS WITH <br /> KITCHEN SUPPLIER DRAWINGS. <br /> "SEMCO" #1100R FLASHING <br /> PUBLISH HISTORY: <br /> TURNED IN ON CAST IRON DATE REVISION <br /> VENTS 3" & LARGER ONLY. wti, <br /> 08.21.20 PERMIT APPLICATION <br /> F I <br /> N FINISHED FLOOR <br /> I ! <br /> r <br /> I I <br /> EXTEND WHERE REQ'D <br /> N <br /> 4 '• TO CLEAR FRESH AIR <br /> . :4 PERMASEAL I INTAKES, ETC. <br /> WATERPROOF WATER PROOFING I <br /> N MEMBRANE FLASH COMPOUND !�"SEMCO" CAULK TYPE <br /> LEAD INTO • • <br /> CLAMPING COLLAR °: ,A.° ' 4 ` CLAMPING COLLAR I I SLE EVE FOR CASTUNTER IRON <br /> 01 <br /> e: "SEMCO" SEAMLESS LEAD <br /> VENTS AND THREADED <br /> f OR CAULK TYPE FOR <br /> o <br /> FLASHING W/18" SKIRT ALL STEEL VENTS <br /> 03 <br /> IAND STEEL VARIABLE ! <br /> TP-1, WATERLESS PITCH BOOT <br /> TRAP PRIMER. 10 <br /> f <br /> i00 <br /> 00 <br /> Q <br /> Q I I SET SKIRT OVER ROOF FELT <br /> � <br /> Li <br /> Jo VENT PIPE - SEE <br /> WMB PROJECT: <br /> PLANS FOR SIZE 20,030 <br /> z <br /> CDQ <br /> 0 <br /> 't Ems, ALEXANDER SCHEFLO <br /> 0 <br /> A•s` and ASSOCIATES, Inc. P8.0 <br /> ='�� Mechanical Engineers (209) 948-9761 <br /> IFUNDIR �] MMR <br /> 2926 Pacific Ave. Stockton, Ca. 95204 <br /> - V E EI V T cr U M 025588 <br /> Ci� /� Exp. 09-30-20 <br /> / D��W�� ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN <br /> D LLL"`��7 LLLIII NOT To SCALE 9 �f CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE <br /> ROOF D1E. HAN� p� ENGINEER AND THE SAME MAY NOT BE USED, DUPLICATED OOF' CAS-\ DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ENGINEER. <br /> To SCALE c� Alexander Scheflo & Assoc. Inc <br /> Copyright WMB <br />
The URL can be used to link to this page
Your browser does not support the video tag.