Laserfiche WebLink
'L <br /> 66 <br /> SA N of O A Q U I N' % Z 2 Environmental Health Department <br /> COUNTY— <br /> Equipment <br /> OUNTYEquipment shall be sealed to the floor or raised 6 inches off the floor by means of <br /> easily cleanable legs or feet. (CRFC Section 114301) <br /> �alls and ceilings shall be constructed so surfaces are impervious, smooth and <br /> w cleanable. (CRFC Section 114301) <br /> 9. Potable water tanks shall be sufficient in volume to fulfill the required 5 gallon minimum <br /> for hand washing. Facilities with limited food preparation must provide at least 15 <br /> additional gallons of water for warewashing. For any preparation beyond limited food <br /> preparation at least 25 additional gallons of water for waFwashing and food <br /> preparation us_t be provided. (CRFC S ction 114217) 30 gallons tank for potable <br /> water a 45 Ions tank for waste w er are required minimum. I <br /> 10.Wastewater tanks shall have a minimum capacity that is 50 percent greater than the <br /> potable water tanks. In no case shall the wastewater capacity be less than 7.5 gallons. <br /> Where potable water for the preparation of a food or beverage is supplied, an additional <br /> wastewater tank capacity equal to at least 15 percept of the water supply shall be <br /> provided. (CRFC Section 114323 (b)) qo Y14 ntw <br /> a Wva!k <br /> Food service openings: a. Shall be no more than 216 square inches and no less than <br /> 18 inches apart. b. Shall be covered with solid material or screen. If screen is used it <br /> must be at least 16-mesh per inch.(CRFC Section 114259.2) <br /> 12.0 both sides of the vehicle. Provide the name of the business in 3 inches high, the <br /> ame of the owner in 1 inch high, and the City State and Zip code in 1 inch high. These <br /> are minimum heights. <br /> 1 e handwashing shall be separated from the warewashing sink or food preparation / <br /> storage areas by a metal splash guard, if separation is less than twenty-four (24) <br /> inches. Splash guard shall be at least six (6) inches in height from back edge to front <br /> edge [CRFC §113953]. <br /> 1.obile Food Facilities where nonprepackaged food is cooked, blended, or otherwise <br /> prepared shall provide a warewashing sink with at least three compartments with two <br /> integral metal drainboards. The dimensions of each compartment of the <br /> warewashing sink shall be at least 12 inches wide, 12 inches long, and 10 inches deep, <br /> or large enough to accommodate the cleaning of the largest utensil. Each drainboard <br /> shall be at least the size of one of the sink compartments. The drainboards shall be <br /> installed with at least one-eighth inch per foot slope toward the sink compartment, and <br /> fabricated with a minimum of one-half inch lip or rim to prevent the draining liquid from <br /> spilling onto the floor. (CRFC Section 114313) <br /> 15.Except as specified in subdivision (c), all new and replacement food-related and <br /> utensilrelated equipment shall be certified or classified for sanitation by an American <br /> National Standards Institute (ANSI) accredited certification program. In the absence of <br /> 2of3 <br />