My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EIGHT MILE
>
2994
>
1600 - Food Program
>
PR0547204
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2021 12:14:02 PM
Creation date
10/7/2021 3:50:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547204
PE
1625
FACILITY_ID
FA0026788
FACILITY_NAME
BURGER KING #27834
STREET_NUMBER
2994
Direction
W
STREET_NAME
EIGHT MILE
STREET_TYPE
RD
City
STOCKTON
Zip
95209
CURRENT_STATUS
01
SITE_LOCATION
2994 W EIGHT MILE RD
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
rn <br /> T <br /> 0 <br /> 0 <br /> STEP-4 <br /> w <br /> 1. LOOSEN AND RELOCATE VL COLLAR TO "H" DIMENSION AS MEASURED IN o <br /> STEP 1. RETIGHTEN SCREWS ON COLLAR. <br /> STEP-1 (DO NOT REMOVE COLLAR FROM PIPE SECTION.) <br /> 0 <br /> A. COORDINATE WITH THE LATEST KITCHEN EQUIPMENT PLANS PRIOR TO <br /> INSTALLATION OF CURB. VERIFY WITH GENERAL CONTRACTOR. VL COLLAR 2. IF NEEDED, TRIM EXCESS DUCT LENGTH TO FINISHED LENGTH OF 11H"+3 Q <br /> B. MARK AND PLUMBOB THE LOCATION OF THE ROUND OPENING FROM FLOOR USING "H" LENGTH MEASURED IN STEP 2. Cn <br /> z z <br /> INNER DUCT ~ <br /> TO DECK. `" <br /> C. PLACE CURB OVER OPENING BY USING DIMENSION GIVEN BELOW. "H" "H"+1" MIN. NOTE: FINISHED LENGTH OF"H"+1" (MINIMUM) UP TO "H+3" w <br /> "H"+3" MAX. (MAXIMUM) IS ACCEPTABLE. <br /> D. WHEN GREASE FLANGE ARRIVES PLACE ON CURB WITH ROUND OVER r <br /> OPENING IN DECK. TRANSITION DUCT <br /> 0 <br /> FAN ADAPTER PLATE w <br /> Y <br /> U <br /> w <br /> HVAC CONTRACTOR SHALL NOT 0 <br /> DISASSEMBLE THE EXHAUST FAN TO7 ° gum@. <br /> IPIC - 3G Factory- Built Grease Duct <br /> RECONFIGURE THE EXHAUST DISCHARGE <br /> 1411 Installation Instructions <br /> STEP-4b Rotate duct 180 <br /> Specific for Burger King Restaurant Installation <br /> (Forward Discharge Assembly) m w <br /> 46" I 46-1/2" <br /> FAN ADAPTER PLATE Q <br /> Note: These instructions have been developed in coordination for use with kitchen exhaust hood o <br /> TRANSITION DUCT manufactured by Gaylord Industries. <br /> N I <br /> 0 <br /> M I <br /> 0 <br /> M _ INNER DUCT GENERAL INFORMATION <br /> 35- 1/4" <br /> QVL COLLARMetal-Fab Model IPIC-3G grease duct is "Listed" by Underwriters Laboratories for kitchen exhaust duct W <br /> FLANGED CURB EXHAUST PLATE applications for continuous operations at 500' F and intermittent operation at 2000' F. IPIC 3G is further <br /> ROOF CURB "C Icssified" by Underwriters Laboratories as equivalent to c 2hr. fire rated grease duct enclosure as per UL <br /> 2221 test standard and listed for Zero inch clearance to combustibles for sizes up to and including 24-inch <br /> PLAN VIEW OF ROOF CURBS inside diameter. �Y <br /> Warning: During this installation, field application of factory-supplied insulation must be installed at joints <br /> and on Variable Length / Adjustable Length components. Do not substitute insulation with other makes or z <br /> STEP-5 BROILER THE FOLLOWING INSTRUCTIONS ARE STEP-5 FRYER �, <br /> (BROILER) <br /> USED TO ALIGN THE GREASE DUCT TO ( ) brands. Upon completion of installation, 2 layers of 1 .5-inch insulation (supplied by manufacturer) must be w >_ O <br /> THE HOOD OUTLET COLLAR. applied directly around the inner duct as described in these instructions in order to maintain the Zero-inch v Q 0-) <br /> clearance to combustibles rating as per the manufacturer's UL listing. L <br /> ROOF CURB 1. TURN THE DUCT ASSEMBLY OVER& ROOF CURB O'� rr) <br /> CAREFULLY SLIDE THROUGH THE FAN FOR QUESTIONS CALL METAL- EAB @ 1 - 800 - 835 - 2830 X 4165 o Q <br /> STEP-2 BROILER HOOD STEP-2 (FRYER HOOD) cuRB. o <br /> 2. CONTINUE LOWERING THE Q �,j LO <br /> ASSEMBLY, AS IT APPROACHES THE Q ch <br /> 30" HOOD, ALIGN THE OUTLET COLLAR& Q � Q w <br /> ROOF CURB 30" - SLIP THE ASSEMBLY INTO THE Q LLJ CC z <br /> ROOF CURB METAL-FAB OUTLET COLLAR. ,� METAL-FAB OUTLET STEP-7 = �, > Q <br /> COLLARCOLLAR <br /> 3. CHECK THE FAN ADAPTER PLATE <br /> FOR PROPER POSITION. THE OUTSIDE • <br /> EDGE OF THE FAN ADAPTER PLATE ROOF CURB <br /> SHOULD BE APPROXIMATELY 1/4" <br /> = MEASURE DISTANCE APPROX. 61" FROM EDGE OF ROOF CURB. <br /> (SHOULD BE APPROX. 58") 4. NOTE: IF THE FAN CURB IS NOT <br /> PROPERLY ALIGNED TO THE HOOD <br /> METAL-FAB METAL-FAB OUTLET COLLAR, THE FAN ADAPTOR VL COLLAR <br /> OUTLET COLLAR 10" 1.D. F/`Z <br /> OUTLET COLLAR PLATE CAN BE TRIMMED TO RE-ALIGN. V-BAND rn <br /> r` <br /> ONCE ALIGNMENT IS ESTABLISHED ^l U 17 <br /> 1. 16 GAUGE SQUARE OFFSET } <br /> I VJ � � U-)32" WELDED TO DISCHARGE COLLAR PROCEED TO STEP-6 TO SEAL AND �U-) <br /> AT THE FACTORY, ON TOP OF <br /> ASSEMBLE GREASE DUCT TO ~ U <br /> THE GAYLORD EXHAUST HOOD. EXHAUST HOOD. 0 }Cl) <br /> METAL-FAB OUTLET COLLAR COMES <br /> FROM FACTORY WELDED INTO CAP C/1 C, <br /> 1ox12 - WITH CAP WELDED ONTO TOP OF Q =o <br /> SQUARE OFFSET. <br /> IWO <br /> BROILER 1. LOCATE THE METAL-FAB • <br /> OUTLET COLLAR POSITIONED 2. MEASURE DISTANCE FROM TOP OF U <br /> ON TOP OF THE GAYLORD OUTLET COLLAR TO TOP OF ROOF LO <br /> EXHAUST HOOD. CURB AS SHOWN. FFF---III <br /> Z <br /> FACTORY WELDED OFFSET TO HOOD DISCHARGE COLLAR NOTE: ALL REMAINING INSTRUCTIONS PERTAIN TO BOTH BROILER o� <br /> 2. MEASURE DISTANCE z w <br /> FROM TOP OF HOOD OUTLET EXHAUST HOOD AND FRYER EXHAUST HOOD AS IN STEP-5. <br /> COLLAR TO TOP OF ROOF CURB Jo <br /> AS SHOWN. FRYER <br /> 0 <br /> 1. APPLY A BEAD OF SEALANT TO V-BAND CLAMP AND ATTACH TO <br /> STEP-6 JOINT AS SHOWN. REF. TO STEP 3. <br /> 2. TIGHTEN SCREWS ON VL COLLAR. (FOR MORE POSITIVE <br /> SEAL, APPLY SEALANT TO VL COLLAR SLOT AND FLARED <br /> GREASE DUCT OUT END OF COLLAR PRIOR TO TIGHTENING SCREWS.) <br /> ASSEMBLY v ER <br /> SEALANT <br /> STEP-8 <br /> PLAIN END SCALE X 4 TECH SCREWS w Q <br /> w ~ � <br /> STEP-3 APPLY THIN FILM OF SEALANT a o■ <br /> 1. REMOVE THE OUTER CASING & INSULATION FROM THE VARIABLE (APPROX 1" WIDE) ,� ROOF CURB ROOF CURB <br /> LENGTH (VL) DUCT. y <br /> VL COLLAR (DO NOT DISCARD INSULATION OR CASING. IT WILL BE USED LATER). 7/7; <br /> INNER DUCT 2. PLACE THE "TRANSITION DUCT/FAN ADAPTER PLATE" UPSIDE DOWN OVERLAP (ALIGN BEADS) <br /> (OUTER CASING ON THE ROOF (FAN ADAPTER PLATE AGAINST ROOF). APPLY SEALANT VL CASING <br /> NOT SHOWN) <br /> 3. APPLY 1/4" BEAD OF SEALANT(PROVIDED)TO FLANGE. OUTLET COLLAR FLANGE 3/4" OVERLAP <br /> VL COLLAR SECURE W/ SCREWS <br /> INNER DUCT FLANGE 1. APPLY A 1/4" BEAD OF SEALANT ONTO THE FLANGE OF THE w <br /> OUTLET COLLAR. (SIMILAR TO BEAD OF SEALANT USED TRIM FLUSH IF NEEDED Q Z <br /> TO ASSEMBLE DUCT SECTIONS IN STEP 3). J Q <br /> Li <br /> Z4. APPLY SEALANT TO INSIDE GROOVE OF V-BAND. <br /> TRANSITION DUCT 2. APPLY A THIN COAT OF SEALANT ABOUT 1"WIDE ON z <br /> (THE V-BAND IS USED TO CLAMP INNER DUCT THE INNER DUCT DIRECTLY ABOVE THE FLANGE OF z <br /> __Z FLANGES TOGETHER.) THE COLLAR AS SHOWN. (NOTE: PLAIN END OF THE INNER w Q O_ <br /> DUCT MUST EXTEND AT LEAST 1" PAST FLANGED COLLAR). <br /> 5. SET INNER DUCT FLANGE ON TRANSITION DUCT FLANGE. '� Q <br /> FAN ADAPTER PLATE--//7 <br /> V) <br /> 3. CAREFULLY SLIDE GREASE DUCT ASSEMBLY THROUGH 1. THE VARIABLE LENGTH (VL) CASING IS MADE UP OF (2) HALF-JACKETS. N[if W Q <br /> THE FAN CURB AS SHOWN. LOWER ASSEMBLY INTO BUILDING, WRAP VARIABLE LENGTH (VL)CASING COMPLETELY AROUND THE INSULATED m i <br /> AND INSERT PLAIN END INTO OUTLET COLLAR OF HOOD. VL DUCT. THE CASING SHOULD OVERLAP THE DUCT ABOVE THE VL AS <br /> O SHOWN. TRIM THE PLAIN END OF (VL)CASING SPACE IF NEEDED TO FIT THE V <br /> 4. IF NEEDED, REPOSITION VL COLLAR UP AGAINST OUTLETFINISHED HEIGHT OF THE VARIABLE LENGTH (VL). OVERLAP SEAMS OF THE cw„ Z <br /> O COLLAR FLANGE. SEALANT SHOULD BE COMPRESSED TO HALF JACKETS BY 3/4"AND SECURE USING SCREWS PROVIDED. , 0 U <br /> 1. ATTACH THE V-BAND CLAMP OVER THE INNER DUCT FORM A LIQUID TIGHT SEAL. w 0 0 <br /> of N <br /> SCALE X4 FLANGES. < Ln <br /> L <br /> 5. SECURE DUCT ASSEMBLY TO FAN CURB USING TECH SCREWS (NOT SUPPLIED). LL! w Q m <br /> NOTE: WHEN ATTACHING CLAMP BAND USE A RUBBER IMPORTANT: RECTANGULAR PLATE OF DUCT ASSEMBLY MUST BE EVENLY CENTERED 0 0 Q <br /> OVER FAN CURB. BEFORE SECURING TO FAN CURB VERIFY THAT OUTER SURFACE r1 ~ <br /> MALLET (OR OTHER)TO AID IN ASSEMBLY. TIGHTEN = z <br /> V-BAND CLAMP USING HEX DRIVE SCREWS PROVIDED OF GREASE DUCT MAINTAINS A MINIMUM 1-INCH CLEARANCE TO COMBUSTIBLE 0 o w o J <br /> TO COMPLETE A LIQUID TIGHT SEAL. MATERIALS. Q Copyright 2 01 5 Drawings, specifications, notes, database, �w 0 0 U Q <br /> 6. HVAC CONTRACTOR SHALL PROVIDE AND INSTALL HIGH TEMP SEALANT OR GASKET TO computer files, field data, and reports as instruments of service prepared by Ir <br /> 1-- <br /> 0 m � o w <br /> THE OUTER PERIMETER OF THE GREASE FLANGE. :5i <br /> the Design of Record. As instruments of services, these items remain the <br /> property of the Design of Record, who shall retain all statutory and other M 11 <br /> reserved rights, including the copyright thereto. Any use, reproduction or <br /> changes to these documents without written consent of NCA Consultants is a <br /> violation of federal co ri ht laws. <br />
The URL can be used to link to this page
Your browser does not support the video tag.