My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5202
>
1600 - Food Program
>
PR0547134
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2021 12:05:33 PM
Creation date
10/12/2021 3:52:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547134
PE
1625
FACILITY_ID
FA0026740
FACILITY_NAME
IN-N-OUT BURGERS
STREET_NUMBER
5202
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
5202 PACIFIC AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STRUCTURE <br /> WIRING LEGEND 208V-30 QE Q <br /> UNIT MO FURNISHED & INSTALLED BY <br /> MECH. CONTRACTOR <br /> RA QE FURNISHED & INSTALLED BY DISCONNECT E <br /> WALL 10" CLEARANCE UNION <br /> ELECT. CONTRACTOR Architecture / Development <br /> STRUCTURE CONDENSATE DRAIN ME FURNISHED BY MECH. CONTRACTOR & <br /> DIMENSIONS INDICATED ON PLAN DUCT WITH 1" ACOUSTICAL LINE WITH TRAP INSTALLED BY ELECT. CONTRACTOR. <br /> VIEW ARE INSIDE CLEAR LINING FC 1" HIGH STUB OPEN UNIT BASE RAIL <br /> <A-RA 1 TO ATMOSPHERE 14901 Quorum Drive <br /> SPUN ALUM. HOUSING <br /> VIBRATION ELIMINATORS � 1/2" X 2" NEOPRENE Suite 300 <br /> GASKET Dallas Texas 75254 <br /> UN-USED DISCONNECT � <br /> USE BIRDSCREEN SWITCH Ph: (972)239-8884 <br /> Ell I <br /> �((7 1,,, I SILOFLEX D SA 16 GAUGE "S" HOLD DOWN ) A2 q3 Fax: (972)239-5054 <br /> ALL <br /> SECURE FAN TO CURB W/ SA CLIP, 6" LONG, 4-PER UNIT ISSUE RECORD <br /> S.M. SCREWS 12" OC ALL <br /> AROUND LONE PER SIDE) 120V1-10 QE <br /> I 2'-MIN. SPUN ALUM. COMPONENTS INSULATION DATE DESCRIPTION <br /> L11FOAM RUBBER GASKET TO--' O COUNTER FLASHING BY <br /> CEILING CEILING UNDERSIDE OF FAN CURB WALL SLEAVE FOR REFRIGERANT MECHANICAL CONTRACTOR. 16 GAUGE URBAN DESIGN PROTOTYPE <br /> CAP SIDE LINES, DRAIN, POWER, AND SIGNAL FRONT <br /> METAL ROOF CURB 24V WIRING 7-10-2020 ISSUED FOR PERMIT <br /> TRANSFER -��- FLASHING <br /> GRILLE TRANSFER NOTE: CURBS AND FANS SHALL BE WIRELESS TEMPERATURE <br /> ROOF STRUCTURE, SEE CONTROLLER (STANDARD) DUCT <br /> I ELEVATION VIEW (TRANSFER DUCT) GRILLE FROM SAME MANUFACTURER ARCHITECTURAL DRAWINGS -FOR DETAILS INSULATED REFRIGERANT LINES ROOFING 4"X FRT DF#1 <br /> NOTES: CANTS LEVELING BLOCK. <br /> 1. SEE ARCHITECTURAL DRAWINGS FOR CEILING TYPE DUCT EXTENSION BACKDRAFT DAMPER 3"MIN SHAPE TO LEVEL <br /> AND HEIGHT. <br /> UNIT. <br /> 2. SEE PLANS FOR TRANSFER GRILLE TYPE AND SIZE. <br /> 7 DUCT SMOKE DETECTOR 24V WIRING-4 WIRE KELECTRONIC <br /> SEE PLUMBING DRAWINGS C 3" FLEXIBLE DUCT FURN. BY MECH. CONTR. PROGRAMMABLE <br /> FOR GOND. LINE ROUTING C THERMOSTAT M <br /> CONNECTION INSTALLED BY MECH. CONTR., SYSTEM CONTROL <br /> FAN COIL CONDENSATE DRAIN LINE WIRED BY ELECT. CONTR. PANEL SIZE PER OWNERS SPEC'S <br /> BACK <br /> TRANSFER DUCT R00 ,/ <br /> 13 SCALE: NOT TO SCALE BLOCKIN <br /> 11 BATHROOM EXHAUST FAN 09 FSCALE: NOT TO SCALE AN T COIL UNIT DETAIL WTO SCALE IRING DIAGRAM REVISION RECORD <br /> REMOTE THERMOSTAT <br /> NOTE: COORDINATE EXACT ROOF CONSTRUCTION MEANS AND METHODS SENSORS PLACED <br /> WITH ARCHITECTURAL AND STRUCTURAL PLANS. SCALE: NOT TO SCALE PER M3.0, NOTE 6 <br /> CURB DETAIL <br /> EL. CONDUIT (WALL, CEILING SIM.) SECURE REFRIGERANT LINES @—aSc <br /> TU NOT TO SCALE <br /> EL. CONDUIT TO PIPE PIER WITH PIPE CLAMP. <br /> EL. BOX <br /> BLOWER MOTOR COVER 8 HOUSING <br /> WIRE LIQUID LINE FILTER DRYER CU 18" <br /> AND SIGHT GLASS 1 <br /> TO STRUCTURE ACOUSTICAL FLEX. <br /> SWITCH OR POWER CONDUIT FOR LIGHTING DUCT O <br /> FIXTURE IN CEILING DUCT LL <br /> REMOTE START <br /> PIPES (WALL, CEILING SIM.) CONTROL <br /> o Q c <br /> METAL DUCT <br /> BETWEEN STUDS <br /> JOINT COMPOUND AND <br /> 2" WIDE SHEET <br /> nz <br /> DRY WALL TAPE STRAP <br /> SECURE UNIT TO PAD WITH <br /> WITH 16 GA. METAL ANGLE <br /> SQUARE TO ROUND CLIPS AT EACH CORNER AND DISCHARGE <br /> CHROMIC ESCUTCHEON ADAPTER 3/8"x3" CONCRETE ANCHORS. SCOOP VENT OVER <br /> WHERE OCCUR JOINED PER MANUFACTURERS USE MASON INDUSTRIES GREASE HOOD EXHAUST FAN OUTLET :AL <br /> FINISH RECOMMENDATIONS a 3/4" NEOPRENE SUPER W <br /> WAFFLE PAD. o <br /> EL. CONDUIT, PIPES (GONG. SLAB) V p 4" LEVEL PLATFORM POWER TO FAN F SS/p� <br /> TILE WITH GROUT (BY GF . u GRE POINT AGAUGE BVENTILATED WALL AT TOWER WALL AT TOWER �� R /Al F <br /> !I L - RECEPTACLE O AF Z <br /> c_ <br /> W/P �3 ET-COCK No. M29234 1� <br /> CONC. SLAB NOTE: VALVE a a• a < PER 2016 CMC 603.4.1, FLEXIBLE DUCTS CEILING EXHAUST <br /> Exp. 06/30/21 <br /> AND CONNECTORS SHALL NOT BE MORE THAN FAN BASE TO GREASE CPQ \P <br /> Ae.'.• Aa.'•.• <'.' Z Q <br /> • a•. . a. . .• . a.•. . a REFRIGERANT LINES INSULATED FAN <br /> 5 FEET IN LENGTH AND SHALL NOT BE USED WITH ARMSTRONG 3/4" ARMAFLEX U DUCT 71 �HAN� <br /> IN LIEU OF RIGID ELBOWS OR FITTINGS AND COVERED WITH CHILDERS d) FLASH CURB ALL 9TF <br /> CONDUIT / PIPE FOAM TAPE ALUMINUM WEATHERPROOF JACKET. v Q WELDED AIR FLOW OF CALF 0/14/20 <br /> ROOF TOWER ROOF <br /> 12 <br /> CONDENSING UNIT DETAIL CONCEALMENT OF CONDUITS @—RCFLOOR <br /> U100D NAILERSCALE: NOT TO SCALE SCALE: NOT TO SCALE <br /> BUILT-UP ROOFING <br /> STRUCTURAL SUPPORT <br /> ON ROOF f DUCT <br /> ROOF DECK PENETRATION BY <br /> GEN. CONTR. OA CO2 EXHAUST FAN DETAIL <br /> LEVEL METAL ROOF CURB AF SCALE: NOT TO SCALE <br /> AIR FLOW BANDING — 304 SSGREASE EXHAUST FAN DETAIL engineering consultants <br /> BLOWER MOTOR COVER & HOUSING 3/4"W x .015" THK MIN 06 SCALE: NOT TO SCALE 14901 Quorum Dr. #565 Dallas, TX 75254 <br /> rtmassociates.com � 972.387.3500 <br /> 3"MIN LONGITUDINAL OVERLAP .•��, <br /> AT BLANKET JOINT �.•� 20.GHAA.027 <br /> 2X WEB BLOCKING AS 2x4 BLOCKING (FLAT) EYE BOLT <br /> 3" MIN PERIMETER OVERLAP .`� TWO LAYERS 1-1/2" THICK REQUIRED <br /> 12" x 8" MINIMUM DUCT AT BLANKET JOINT 1" —1/2" <br /> ASTM 2336 APPROVED FIRE PROTOTYPE VERSION <br /> CLEAN OUT (TYPICAL). 1-1/2" RATED DUCTWRAP FOR 6U.2.61 <br /> WHERE CLEANOUTS OCCUR HOOD EXHAUST DUCT '6' '� �. MIN. ONE HOUR FIRE RATING <br /> IN FIRE—RESISTANCE—RATED <br /> ENCLOSURE, PROVIDE 10-1/2" (STAGGER JOINTS 12"BETWEEN <br /> SLIDING OR HINGED DOORS 16 GAGE STEEL GREASE JOINTS). 3M FIRE BARRIER DUCT <br /> EQUAL IN FIRE RESISTIVE EXHAUST DUCT. PROTECT DISCHARGE WRAP 615+ OR THERMAL 2X WEB BLOCKING EACH PROJECT NAME <br /> PROTECTION TO THAT OF AGAINST CORROSION SCOOP CERAMICS FIREMASTER. SIDE (TYPICAL) <br /> ENCLOSURE. REFERENCE GREASE HOOD EXHAUST FAN <br /> 02/Ms.o Low POINT 1-1 0" RATED CLEARANCE <br /> GREASE 21"TYP INN 0 U T <br /> RECEPTACLE 10-1CM <br /> W/PET-COCK <br /> NOTE: / BURGER <br /> GREASE 1.WRAP SUPPORT HANGER SYSTEM INDEPENDENTLY WITH SAME THICKNESS FOR SIMPSON A34 CLIP UNDER / <br /> DUCT SLOPE AT 2% EXTERNAL FIRE THREAT CONDITIONS. FLAT BLOCKING EACH END / <br /> ALL f <br /> 2" X 2" ANGLE IRON WELDED 2. WRAP GREASE DUCT CONTINUOUS AS SHOWN BELOW FOR ENTIRE LENGTH FROM <br /> SUPPORT FRAME KITCHEN HOOD CONNECTION TO EXHAUST FAN ON ROOF. SUPPORT FROM STRUCTURE <br /> 3. BANDING REQUIREMENTS: USE 304 STAINLESS STEEL FOR MIN. ONE HOUR WITH 0.25" THREADED ROD STO C I(TO N <br /> MAKE SMALLEST RATING OR 1" WIDE 22 A STRAP <br /> RADIUS POSSIBLE 16 GAUGE VENTILATED <br /> FAN BASE. <br /> TWO LAYERS OF ASTM 2336 i CALIFORNIA <br /> APPROVED FIRE WRAP - ROOF 1" WIDE 22 GAUGE <br /> \ <br /> EXTEND TO CURB FLANGE 29 1/2" HANGER BAND MAX — <br /> CURB TO CURB 10'-0" SPACING - - / 5202 PACIFIC AVE <br /> 02 KITCHEN EXHAUST DUCT SYSTEM STOCKTION, CA 95207 <br /> SCALE:NOT TO SCALE SUPPORT FROM <br /> UL LISTED GREASE DUCT WITH TWO LAYERS OF STRUCTURE WITH <br /> ASTM E 2336 LISTED AND LABELED GREASE DU DUCTMATE EZ-LOCK <br /> ENCLOSURE SYSTEM. THERMAL CERAMICS CABLE SUPPORTS TO <br /> FIREMASTER FAST WRAP DUCTWRAP XL OF BRACE DUCT <br /> 3M FIRE BARRIER DUCT WRAP 615+, LATERALLY FROM <br /> 0" RATED CLEARANCE EACH SIDE. MAX. <br /> 10'-0" SPACING ROUND SPIRAL SEAM <br /> DUCT SEE PLAN FOR <br /> SIZE <br /> MATERIALS AND INSTALLATIONSHAMoNmOUT <br /> MCSTANDARDS <br /> LMACNA AND 2019 <br /> WEATHERPROOF C <br /> UNIT DISCONNECT <br /> \BURGER® <br /> TRANSVERSE & LONGITUDINAL <br /> DUCTMATE TO BE LOCATED CABLE BRACE (TYP.) GOD BLESS AMERICA <br /> ROOFTOP UNIT AT SEISMIC RESTRAINT <br /> LOCATIONS. SEE DETAILS OF TYPICAL <br /> III III NON-COMBUSTIBLE CEILING. REFERENCE INSULATED ROOF CURB. THERE CABLE CONNECTIONS TO <br /> ARCHITECTURAL DRAWINGS. SHALL BE A MINIMUM OF 12" <br /> STRUCTURE. <br /> 0 <br /> CLEARANCE FROM THE TOP OF THE 0 <br /> III III 16 GA S/S METAL TRIM ROOF MOUNTED CURB TO THE TOP REFERENCE 3/P1.1 FOR RTU <br /> ALL AROUND FINISHED SURFACE OF THE ROOF. CONDENSATE PIPING DETAIL 30' - 90° DUCT <br /> IIIIII STAINLESS STEEL ENCLOSURE I. I El 1 45° PROJECT NUMBER <br /> III III TO ELEC. PANEL I I SMOKE DETECTOR TO SHUT DOWN 190955 <br /> III III MINIMIZE ROOF I I UNIT UPON ACTIVATION SUPPORT ROD (SHOWN) WITH <br /> OPENINGS AND SEAL J I I CONNECT TO R.A. RISER ROD STIFFENER. SEE ROD SHEET TITLE <br /> STIFFENER DETAILS FOR <br /> IIIIII J REQUIREMENTS. <br /> 16 GUL LISTEDLHOODLDED SUPPLY JJJ//II I I RETURN o o MECHANICAL <br /> — — — — — — — — — — — SEE DETAILS 0 F TYPICAL DETAILS <br /> 1" RIGID INSULATION BOARD FOR CABLE CONNECTIONS TO <br /> 0 2 FLAMEGUARD FILTERS AT GRILL SOUND ISOLATION. SECURE TO BRACED COMPONENTS. <br /> LMANUAL O.B.D. FOR <br /> N <br /> rn (3 AT FRYERS) INSIDE OF ROOF CURB BALANCING SUPPORT MEMBER <br /> z I SUPPORT MEMBER <br /> :LIJ <br /> :E � ROOFTOP UNIT DETAIL DUCT ATTACHED TO SUPPORT MEMBER PIAN VIEW OF BRACE <br /> SCALE: NOT TO SCALE <br /> W SHEET NUMBER <br /> U DUCT SEISMIC MOUNTING DETAIL <br /> U O <br /> IGREASE EXHAUST DETAIL <br /> o O3 SCALE: NOT TO SCALE SCALE: NOT TO SCALE <br /> M5mO <br /> z z <br />