My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
5202
>
1600 - Food Program
>
PR0547134
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2021 12:05:33 PM
Creation date
10/12/2021 3:52:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0547134
PE
1625
FACILITY_ID
FA0026740
FACILITY_NAME
IN-N-OUT BURGERS
STREET_NUMBER
5202
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
CURRENT_STATUS
01
SITE_LOCATION
5202 PACIFIC AVE
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\jcastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
89
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES BY SYMBOL "0 " <br /> OROUTE 3/4" HW AND CW DOWN IN WALL TO SERVICE SINK FAUCET. 0 ( ) 0 24 PROVIDE SHUT-OFF VALVE FOR EACH CW BRANCH IN RISE. ACCESS PANELS <br /> 0 a INSTALL SOLENOID VALVE FURNISHED BY OWNER). PROVIDE SHUT-OFF VALVES 1 FIRE LINE MUST ENTER BUILDING IN THE GENERAL AREA SHOWN. <br /> REQUIRED FOR ALL VALVES RECESSED IN WALL. LABEL EACH SHUT OFF VALVE. <br /> COORDINATE WITH FIRE PROTECTION DRAWINGS FOR EXACT LOCATION. IN <br /> PROVIDE 1" CW FROM FIRE RISER RM. TO BEVERAGE AND R.O. AND UNIONS ON EACH SIDE. INSTALL ACCESS PANEL (24X24) FURNISHED BY Architecture / Development <br /> FILTERS. PROVIDE SHUT-OFF VALVES (SOV) ON BRANCH TO FILTERS. REF. COORDINATE WITH ADJACENT HVAC DIFFUSER AND SEE A7.0. NO CASE SHALL THE FIRE RISER BE LOCATED GREATER THAN 5'-0" FROM 25 PROVIDE 6" DIRT LEG WITH CAP AT BOTTOM OF 2" DROP TO MANIFOLD. <br /> TWO 1" STUBS SUPPLY AND DISTRIBUTION FROM CEILING, BOTH THE EXTERIOR WALL UNDER WHICH THE FIRE RISER LINE ENTERS BUILDING. <br /> ( ) 14901 Quorum Drive <br /> ARE TO HAVE Y4"NIPPLES, 12" DOWN FROM CEILING. 0 1y" HOT AND COLD WATER AND %" HOT WATER RETURN UP TO WATER HEATERS s 26 PROVIDE LINE SIZE BALL VALVES (V-3, SEE SHEET P1.1) FOR SHUT-OFF PROVIDE 2" CW SUPPLY FOR WC'S AND BRANCH 1" DIRECTLY TO WC. Suite 300 <br /> ON ROOF. ALONG BACK WALL. NO ANGLE STOPS OR COMPRESSION FITTINGS. Dallas Texas 75254 <br /> 0 2" CW MAY BE ROUTED DIRECTLY ABOVE RESTROOM (WATER CLOSET) 11 1" GAS TO KITCHEN EQUIPMENT. PROVIDE SHUT OFF COCK TO EACH PIECE. CAP 2- INSTALL (2) 2" WATER SUPPLY LINES WITH 2" SHUT-OFF BY-PASS VALVE <br /> WALL. SHOWN OFFSET FROM WALL FOR CLARITY. q GAS PIPING WITHIN WALLS AND ABOVE INACCESSIBLE CEILINGS SHALL BE 1 ASSEMBLY. RECESSED IN WALL, ACCESS PANEL REQUIRED. EXTEND BOOSTER Ph: (972)239-8884 <br /> GRILLS (P-09A) FOR FUTURE. PROVIDE 6" DIRT LEG WITH CAP AT BOTTOM OF DROP. „ >, Fax: (972)239-5054 <br /> O PROVIDE 8x8 SST ACCESS PANEL (CENTERED AT 84' AFF) AT EACH INSTALLED WITH FITTINGS LISTED FOR USE IN CONCEALED LOCATIONS. PUMP SUPPLY AND RETURN PIPING UP IN WALL TO ABOVE CEILING. <br /> VALVE / WATER HAMMER ARRESTOR LOCATION IN RESTROOMS. LOCATE 12 3/4" HW & CW DOWN IN WALL TO SERVE TRASH AREA FAUCET. PROVIDE LINE SIZE INSTALLATION SHALL COMPLY WITH 2016 CPC AND AHJ. ISSUE RECORD <br /> TRAP PRIMER HERE WHERE APPLICABLE. REFER TO A19.0 FOR DETAILS. SOWS IN FIRE RISER ROOM WALL (ACCESS PANEL REQUIRED) AT 24" AFF. INSULATE 2a PROVIDE 2" PVC CONDUIT FROM CO2 TO BAG-IN-BOX. USE LONG SWEEP <br /> 0PROVIDE 3 PVC CONDUIT FOR PRESSURE WASHER HOSE. USE ONLY LONG ELBOWS. REFER TO ARCHITECTURAL PLANS FOR LOCATION AND ELEVATION. DATE DESCRIPTION <br /> O FILTERED WATER DOWN IN WALL HW WITH 1" THERMACEL INSULATION FOR FULL LENGTH. SEE P2.0 FOR CONTINUATION. SWEEP ELBOWS. COORDINATE WITH ROOF DRAINS. REFER TO KITCHEN AND URBAN DESIGN PROTOTYPE <br /> 3 LOCATE HOSE BIBB IN PRESSURE WASHER BOX AT 56" A.F.F. ARCHITECTURAL PLANS FOR DETAILS. 1 29 EXTEND BOOSTER PUMP 2" SUPPLY AND RETURN PIPING ABOVE CEILING TO 7-10-2020 ISSUED FOR PERMIT <br /> O ROUTE 1/2" DRAINS FROM BEVERAGE AND R.O. FILTERS DOWN IN BOOSTER PUMP IN WATER HEATER ROOF TOWER. WATER PIPING TO BE <br /> 14 <br /> WALL. TERMINATE AT FLOOR SINK, REFERENCE SHEET P4.0. PROVIDE BFPD-3 ON WALL FOR CARBONATORS. ROUTE DRAIN INTO WALL AND O ROUTE WATER PIPING IN CHASE LOCATED ON EXTERIOR OF WALL DOWN TO INSULATED FOR SOUND PROOFING AND SUPPORTED WITH PIPE HANGERS. <br /> TERMINATE AT FLOOR SINK. SUPPLY PIPING SHALL ALSO BE RUN IN WALLS. PRESSURE WASHER BOX, REFERENCE KITCHEN DRAWINGS K8.2 DETAILS. <br /> O WATER FROM R.O. FILTER SHALL BE ROUTED IN 3/4" TUBE WITH TERMINATE PRESSURE WASHER HOSE WITH QUICK DISCONNECT PER OWNER'S 30 BOOSTER PUMP 2" SUPPLY AND RETURN PIPING TO BOOSTER PUMP IN <br /> NOTE: REFER TO SHEET K4.0 FOR BEVERAGE TUBES IN 6" PVC (UNDERFLOOR) CONDUITS. REFER TO 0 1-1/4" H & CW TO TURBO WASH AND FILL FAUCETS. PROVIDE 1" REQUIREMENTS. WATER HEATER ROOF TOWER ABOVE. REFERENCE SHEET P5.0 FOR <br /> EQUIPMENT CONNECTION SIZES AND DETAILS. ARCHITECTURAL AND KITCHEN PLANS FOR DETAILS. MINIMUM CONNECTION FILL FAUCET (TO MAXIMIZE FLOW INTO SINK). CONTINUATION. <br /> O PROVIDE 3" PVC CONDUIT FOR TANK REFILL LINE. USE ONLY LONG SWEEP <br /> OBEVERAGE SYSTEM (CARBONATORS) SHALL BE FED THROUGH BEVERAGE MAKE SINGLE CONNECTION TO PLUMBING ON SINKS. REFERENCE NOTE BY ELBOWS. REFER TO ARCHITECTURAL PLANS FOR LOCATION AND ELEVATION. <br /> FILTER AND THEN S/S RPZ (BFPD-3). PROVIDE S/S-316 THREADED 0 SYMBOL NUMBER 15 (ABOVE) FOR CONNECTION SIZE. <br /> R.O. WATER BELOW SLAB IN 2" CONDUIT FROM BEVERAGE TUBING <br /> FITTINGS AND PIPING DOWNSTREAM OF RPZ AND S/S BARBS ON ENDS 03/4" <br /> OF MANIFOLD. TO CHEESE MELTER. REFER TO SHEET K5.0 FOR EXACT LOCATIONS. <br /> 5 <br /> REVISION RECORD <br /> CO2 TANK 10-14-2020 <br /> (REFILL BOX) �CIN COMMENTS <br /> REMOTE GAS METER BY GAS 0 � <br /> n <br /> COMPANY. REFERENCE SHEET - - - - - - - - - - - - - - - - - - - - - - P-22 <br /> P2.0 FOR CONTINUATION. _ _ _ _ _ _ _ _ _ 0 GAS LOAD SUMMARY <br /> 4 � 4 -23A O (3)GAS GRILLES @ 80,000 BTU/H EA= 240 CFH <br /> 7 23 <br /> Y I I (5)GAS FRYERS @ 120,000 BTU/H EA= 600 CFH <br /> Lw <br /> J ❑ / AC-1 @ 180,000 BTU/H = 180 CFH <br /> ❑ �Y2 / 23 AC-2 @ 180,000 BTU/H = 180 CFH <br /> / 7I9 I AC-3 ® 220,000 BTU/H = 220 CFH <br /> II i <br /> I / WH-1 2 ® 199,999 BTU/H EA = 399.9 CFH <br /> 1 -1/4" GAS UP ` � II III' 3" <br /> AC-1 © 180 CIF III / 2 <br /> �I - TOTAL= 1819.9 CFH <br /> „ VIII SEE SHEET K5.0 FOR 1 I I :AL <br /> 4 VIII IIIIIIIIII II IIIIIIII II IIIIIIIIII IIIIII II II VIII a ` CQ IIIIIIII UNDERGROUND CONDUIT RUNS. k1/4" <br /> / I I <br /> IIIIII IIIIIIII II IIIIIII II IIIIIIII IIIIII II II IIII II 3 " P-o1 <br /> I I I I I I I I I o I IIIIII Z4 I I I FSS/ <br /> IIII IIIIIIII II IIIIIII II IIIIIIII IIIIII II II IIII / II IIIIU10II _ D _ DISTANCE FROM METER TO MOST REMOTE CONNECTION 180.5' Oi� <br /> 65'+/- _ — — ` _ 0 MULTIPLIER FOR LOSSES IN SYSTEM (X 1.50) X 1 .50 <br /> = — — — — _ — — _ — — — — — — — _ II IIII I 0 TOTAL DEVELOPED LENGTH OF SYSTEM 270.75' F Z <br /> (TYP.5 1 P-02A 0 w <br /> � Ill�rl II II IIIIIIII II II I111111I II II IIIIIIII II II IIIIIII II II IIII o � �� � I III I � � M No. M29234 <br /> _ f P-118 7" WATER COLUMN LOW PRESSURE GAS PIPING SYSTEM. * Exp. 06/30/21 <br /> _� — _L_ _� — _ __L — _J _ __ L — �_ _J — _ _ / TOTAL DEVELOPED LENGTH OF PIPING SYSTEM = 300'-0" � \CY1Y4" 19 / 2 MANIFOLD q�� 14AN <br /> _ I _ GAS PIPING SYSTEM SIZED FROM THE OF CA1-�F 0/14/20 <br /> _ Y4"�}, I PLUMBING CODE (2019 CPC) TABLE 1215.2(1) <br /> I <br /> Na 2" CONDUIT BELOW \ \ \ \ � 19 11 � / I��I <br /> FLOOR FOR KETCHUP ���L_J <br /> CO2 LINE. (AC�2 @180 CFH) �� IS P <br /> 2 P-41.....-.t. <br /> 4" G UP P-22 P-86 P-87 P-22 P- 19 2" <br /> G DOWN GENERAL NOTES <br /> 9 IN WALL — II ��� 2IN WALL <br /> GAS RISER I BFPD-1 18 �I 600 CFH <br /> AT BUILDING \ IIII V-3 - I P_ 9 9 A. REFER TO SHEET P1.0 FOR GENERAL PLUMBING NOTES <br /> 5 r- APPLICABLE TO ALL PLANS. engineering consultants <br /> P-n III O III 0 I I I P-4s \ <br /> _=I — J — I I BFPD �� 0 B. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS 14901 Quorum Dr. #565 Dallas, TX 75254 <br /> 4-il <br /> 1)/ \ 0 (ESPECIALLY Al2.0, Al2.1, AND A19.0) AND KITCHEN rtmassociates.com 1 972.387.3500 <br /> �4" IN WALL 0 PLANS AND ELEVATIONS (ESPECIALLY K4.0) FOR FINAL <br /> 12 _ _ 2 GAS GAS �4 4 4 / 1/ UNDER WINDOW LOCATIONS OF FIXTURES AND EQUIPMENT. 20.GHAA.027 <br /> SEE P2.0 FOR 3 1, 11 >, — „ 2" » — �, L - _ TO SINK <br /> �4 ��4 �\ 1Y4 „ 3 1„ 7 PROTOTYPE VERSION <br /> CONTINUATION FIRE \ I 1Y4 .. 19 / 19 a / / / 3 �4" 16U.2.61 <br /> — „ " ---- <br /> SEE CIVIL DWGS. FOR 1 �4 / <br /> CONTINUATION FD-1 CFI 22 <br /> 13 _ II PROJECT NAME <br /> - I <br /> 1 P 1 1 / 9' 3 P-116 <br /> U 2' _ 3 S� — 3 4 2 6 \ Y2 <br /> DEDICATED SPACE FOR �7 P-807P-81A WC // - _ 2" QST_ _ C-1 C_1 2/ / WC-2 r 1 <br /> IN-N-OUT <br /> if , <br /> INCOMING FIRE RISER. Hg-2 HB-1 / L 1 L 1 L 1 , BURGER <br /> , ---------- 2•• 0 2" U-1 1Y° I � — � o � „ WH -A o " ,- 0 2 O/ / ° 2 I i � / � <br /> �°1/4„ <br /> COORDINATE 3/4" CW TO - -H2 -T. WC-2 °° W - — J ❑0 1 o °7 F-1 - (r1Y411 1 \ LO <br /> HB-2 WITH FIRE RISER AND P-23A \ / _ - I 1"FW <br /> DRAIN FROM TOWER - ' WALE MOUNT LJ `�� " �� <br /> 3 " „ P-15 6 P-104 �'4 STO C KTO N <br /> 21 4 26 Z4 „ 3 " �4„ cHEM cABNET III �4" P-21 1" .I -- 1Y4» I 1 <br /> INCOMING 2" 2„ 29 ly _ GE oiL�� - - P-09A <br /> DOMESTIC WATER P. - — , O ` <br /> O i = r TA:�ICADDYI 3FW 1 19 80 CFH I — 5 <br /> _ _ _ _ _ _ _ _ _ _ _ EE _ _ _ o CALIFORNIA <br /> I \ BILE 6 /4 KEEP PLUMBING CLEAR OF ONION 0 <br /> 1� I O I " "J 1 " - FW HOOD EXHAUST DUCT CEILING <br /> L- 1 - -Q �� - - - � - - - � � D 2 1 Y2 „ 5202 PACIFIC AVE <br /> � \ 20 B�`i y �• 3 13 PENETRATION. STOCKTION, CA 95207 <br /> 1>, 0 3 1„ <br /> 2„ \ �/ �� — � �/ FA-1 - - 28 - - -LBUN BU BUN BUN /� �4 <br /> RACK RAS ” L RACK if BFPD-3 _A <br /> f -- i - I— <br /> 3" _ P-� 14 BFPD-3 \ / P-25 WATER LINES TO SINK FAUCETS ARE <br /> HEM <br /> AB,NEr 2a 19 2" I / BUILT INTO SINK. PIPING SHOWN OUT <br /> 6 2„ 20 — �� — Y» 3 �4„ 3 , i 16 BFPD-1 CONNECT TOP O.C. ON SINK <br /> OF WALL FOR <br /> PLUMBER <br /> UNIT # <br /> 2 /4 P-25. <br /> Qi 1-1/4" GAS UP P-LP — <br /> ��__ (AC-3 ® 220 CFH) 5 2„ 3- NoNmOUT <br /> o I "-% j '° y <br /> 2" <br /> _ Ik \BURGERe <br /> - - - - -� 02 - - - - -� F � � - -� 2- - GOD BLESS AMERICA <br /> Al F I P-2 <br /> TELEPHONE <br /> - LLLI I �LI <br /> I L-L o Y2" <br /> Ln --- � I I <br /> II � II <br /> PROJECT NUMBER <br /> II 190955 <br /> 10 <br /> 2" GAS UP 0 22 SHEET TITLE <br /> (WH'S @ 399.9 CFH) <br /> Ju WATER AND GAS <br /> PLUMBING WATER AND GAS PLAN 3" PLUMBING PLAN <br /> LO <br /> II <br /> co <br /> SCALE: 1/4" = 1'0" 28 <br /> II <br /> II <br /> 022 � <br /> SHEET NUMBER <br /> o <br /> II II <br /> m � II II <br /> ZZ <br /> II P3mO <br />
The URL can be used to link to this page
Your browser does not support the video tag.