CLIPPED ON TRIM COUNTER SUNK HEAD SCREW (MIN. WALL AS PER PLANSET. DOOR SCHEDULE REVISIONS BY <br /> 3 PER JAMB) <br /> SEALANT OVER DOOR FRAME <br /> BACKER ROD. HARDWARE <br /> GYPSUM WALLBOARD PREHUNG DOOR AND FRAME DOOR# WIDTH HEIGHT MATERIAL FINISH MATERIAL FINISH DOOR TYPE GROUP REMARKS <br /> AS PER DOOR SCHEDULE. <br /> AS PER PLANS. <br /> METAL FRAME <br /> AS PER SCHEDULE AND <br /> SPECIFICATIONS. 101e 6' - 0" T _ 11" METAL MANUF METAL MANUF 2 -- EXISTING, ENSURE COMPLIANCE TO ANSI 117.1 2009 <br /> ANCHOR DOOR FRAME TO 102 T - 0" T - 0" WOOD PAINT METAL PAINT 1 -- <br /> WALL AS PER <br /> 2 X WALL AS PER PLANS. = SHIM AS NEEDED TO ALLOW MANUFACTURER. NOTE: OWNER TO SELECT DOOR MANUFACTURER. <br /> PROVIDE DOUBLE STUD AT DOOR TO BE HUNG SQUARE <br /> OPENING AND LEVEL. SEALANT OVER <br /> BACKER ROD. <br /> HOLLOW METAL DOOR JAMB U <br /> METAL DOOR AS <br /> INTERIOR DOOR JAMB AND PER SCHEDULE AND <br /> 4 NON-BEARING HEAD HOLLOW METAL SPECIFICATIONS. Z 0 <br /> A6.2 1 1/2" = 1'-0" 1 0 <br /> U Ln <br /> DOOR GENERAL NOTES W WM 00 <br /> s METAL DOOR JAMB AND HEAD AT WALL a/ H Ln r <br /> A6.2 1 11211 = 11-011 <br /> A ALL EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF <br /> A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. U < Ln <br /> u�// <br /> C.M.U. BLOCK ALUMINUM FRAME. � U r. <br /> B LOCKING DEVICES AT EXIT DOORS SHALL HAVE A PLAINLY MARKED AND I — <br /> READILY DISTINGUISHABLE MESSAGE PANEL INDICATION WHETHER THE LOCK U - U) <br /> ALUMINUM DOOR. G.W.B. WALL BEYOND. IS IN THE"OPEN" OR "LOCKED" POSITION. Q Q <br /> D00 R WIDTN DOOR WIDTH DOOR HARDWARE: W Q L N <br /> ALUMINUM THRESHOLD. C MANUALLY OPERATED EDGE OR SURFACE-MOUNTED FLUSH FLUSH BOLTS AND <br /> WATER TIGHT DOOR SEAL. 1. PRIVACY T SURFACE BOLTS ARE PROHIBITED AT THE EXIT DOORS. UJ <br /> \ _ / \ WALL BUMMPERPER W X <br /> w \ 4 w / \ CLOSER 0 <br /> EXTERIOR WALK SEALANT CONT. A6 2 C-1 SOUND SEAL D MANUALLY OPERATED EDGE OR SURFACE-MOUNTED FLUSH FLUSH BOLTS AND > W <br /> OR STEPS. BOTH SIDES. 0 / 0 \ / SURFACE BOLTS OR ANY OTHER TYPE OF DEVICE THAT MAY BE USED TO CLOSE 0 <br /> 0 0 NOTE: ALL DOOR HARDWARE TO BE LEVER U <br /> M // o j // TYPE HARDWARE AS PER ANSI A117.1. OR RESTRAIN THE DOOR OTHER THAN BY OPERATION OF THE LOCKING DEVICE <br /> HARDWARE TO BE SELECTED BY OWNER. SHALL NOT BE USED.WHERE EXIT DOORS ARE USED IN PAIRS AND APPROVED 7 <br /> AUTOMATIC FLUSH BOLTS ARE USED,THE DOOR LEAF HAVING THE AUTOMATIC ` <br /> 1/2" EXPANSION JOINT. ° a OOR TYPE 1 DOOR TYPE 2 FLUSH BOLTS SHALL HAVE NO DOOR KNOB OR SURFACE-MOUNTED HARDWARE. Q <br /> a 4a " a �> �•�._ 7 THE UNLATCHING OF ANY LEAF SHALL NOT REQUIRE MORE THAN ONEm <br /> a OPERATION. W <br /> W <br /> m W 'un <br /> l <br /> - - W <br /> r <br /> CONCRETE SLAB. E THE UNLATCHING OF ANY EXIT DOOR SHALL NOT REQUIRE MORE THAN ONE -3 W <br /> OPERATION. IIr—_ i <br /> Q W UJ r <br /> 7 ALUMINUM THRESHOLD F ALL EXTERIOR DOORS SHALL BE WEATHERSTRIPPED I T <br /> o Ln <br /> 6 / 1111 <br /> 0 G HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE CENTERED BETWEEN Q <br /> THIRTY-FOUR INCHES & FOURTY-FOUR INCHES ABOVE THE FLOOR. LATCHING rn� <br /> AND LOCKING DOORS THAT ARE HAND ACTIVATED AND WHICH ARE IN A PATH r U) <br /> OF TRAVEL SHALL BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE <br /> HARDWARE, PANIC BARS, CRASH BARS, PUSH-PULL ACTIVATING BARS, OR W 'n <br /> OTHER HARDWARE DESIGNED TO PROVIDE PASSAGE WITHOUT REQUIRING THE T W N <br /> ABILITY TO GRASP THE OPENING HARDWARE. LOCKED EXIT DOORS SHALL y r %-0 <br /> OPERATE AS ABOVE IN EGRESS DIRECTION. 'n <br /> W I <br /> 0- <br /> H INTERIOR AND EXTERIOR THRESHOLDS SHALL BE NO HIGHER THAN ONE-HALF 0 <br /> INCH ABOVE THE ADJACENT FLOOR LEVELS. EACH EXPOSED EDGE OF <br /> THRESHOLD SHALL BE BEVELED AT 1:2 SLOPE. NO VERTICAL CHANGE OF U <br /> ELEVATION SHALL EXCEED ONE-QUARTER INCH. <br /> I THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF A DOOR THAT SHALL <br /> NOT BE MORE THAT ONE-HALF INCH LOWER THAN THE THRESHOLD OF THE 5ED ARCy <br /> DOORWAY. ALL LANDINGS SHALL BE LEVEL EXCEPT FOR THE EXTERIOR �,� �J. 8 <br /> LANDINGS WHICH MAY HAVE A SLOPE NOT TO EXCEED ONE-QUARTER INCH PER <br /> FOOT OR 2% GRADE. = O <br /> C-25449 <br /> S 6-30-21 <br /> RENEWAL DATE <br /> J MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED FIFTEEN LBS FOR 9T 0 <br /> THE FIRE DOORS, FIVE LBS FOR EXTERIOR DOORS AND 5 LBS FOR INTERIOR SOF CA�-�F <br /> DOORS. SUCH PULL OR PUSH EFFORT BEING APPLIED AT RIGHT ANGLES TO <br /> HINGED DOORS AND AT THE CENTER PLANE OF SLIDING OR FOLDING DOORS. <br /> COMPENSATING DEVICES OR AUTOMATIC DOOR OPERATORS MAY BE UTILIZED <br /> TO MEET THE ABOVE STANDARDS.WHEN FIRE DOORS ARE REQUIRED, THE <br /> MAXIMUM ALLOWABLE BY THE APPROPIATE ADMINISTRATIVE AUTHORITY, NOT <br /> TO EXCEED FIFTEEN LBS. " • <br /> K THE BOTTOM TEN INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING crumbL <br /> DOORS SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE <br /> DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A cookies <br /> TRAP OR HAZARDOUS CONDITION.WHERE NARROW FRAME DOORS ARE USED, A <br /> TEN INCH HIGH SMOOTH PANEL SHALL BE INSTALLED ON THE PUSH SIDE OF INTERIOR TENANT <br /> THE DOOR, WHICH WILL ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR IMPROVEMENT <br /> FOOREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. <br /> LOCATION <br /> 864 W BENJAMIN HOLT <br /> STOCKTON, CA 95207 <br /> L DOOR DETAILS REFERENCED MAY NOT NECESSARILY SHOW HARDWARE SMOKE <br /> SEALS, ETC. REFER TO RATING AND HARDWARE REQUIREMENTS FOR <br /> WEATHERSTRIPPING, DOOR BOTTOMS,OR SMOKE SEAL REQUIREMENTS. A.P.N.: <br /> FRANCHISE OWNER <br /> M ALL GLAZING IN DOORS SHALL BE TEMPERED GLASS, EXCEPT WHERE KTK CO <br /> FIRE-RATED DOORS ARE SCHEDULED, IN WHICH CASE WIRE-GLASS SHALL BE CRUMBL COOKIES- <br /> USED. STOCKTON <br /> N SIGN ADJACENT TO MAIN EXIT DOORS SHALL STATE: "DOORS TO REMAIN <br /> UNLOCKED WHEN BUILDING IS OCCUPIED" WITH 1 INCH HIGH CONTRASTING <br /> LETTERS, PER CBC 1008.1.9.3 #2.2 DRAWN <br /> Author <br /> CHECKED <br /> 0 BARS,GRILLES, GRATES, OR SIMILAR DEVICES PLACED OVER EXIT DOORS SHALL Designer <br /> BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, TOOL, OR ANY <br /> SPECIAL KNOWLEDGE OR EFFORT. SUCH BARS, GRILLES, GRATES, OR SIMILAR DATE <br /> DEVICES SHALL BE EQUIPPED WITH AN APPROVED RELEASE DEVICE FOR USE BY 5/25/2021 3:28:34 PM <br /> THE FIRE DEPARTMENT EMERGENCY ACCESS WHEN REQUIRED BY THE SCALE <br /> AUTHORITY HAVING JURISTICTION. AS SHOWN <br /> JOB NO. <br /> 21-070 <br /> P PROVIDE FOUR SETS OF KEYS FOR ALL LOCKS,TAGGED AND IDENTIFIED. SHEET <br /> Q PROVIDED MASTER LOCK CO #81 PADLOCKS KEYED ALIKE FOR ALL LOCKABLE <br /> SWITCHGEAR, TELEPHONE, HOUSE PANEL, AND TIMECLOCK CABINETS. A602 <br /> OF SHEETS <br />