REVISIONS BY <br /> ELECTRICAL PANEL SCHEDULE INTERIOR LIGHTING FIXTURE SCHEDULE <br /> PANEL A PANEL B T-24 SYMBOL LAMP DESCRIPTION MANUFACTURER & LOAD QUANTITY DETAIL REMARKS <br /> MARK MODELNUMBER <br /> PANEL LOCATION: FEEDERS: SEE ONE LINE-DIAGRAM PANEL LOCATION: FEEDERS: SEE ONE LINE-DIAGRAM <br /> MOUNTING: FLUSH PHASE: 3 MOUNTING: FLUSH CONDUIT: SEE ONE LINE-DIAGRAM <br /> PANEL RATING: 400 AMPS VOLTAGE: 208 PANEL RATING: 100 AMPS VOLTAGE: 120/208 3 PH,4W BUS <br /> DESCRIPTION BRK LOAD CODE A B C CODE LOAD BRK DESCRIPTION DESCRIPTION BRK LOAD CODE A B C CODE LOAD BRK DESCRIPTION 2'X4', 5000K <br /> RECESSED MOUNTED FLAT LITHONIA <br /> 1 3108 5 3108 2 1 LOBBY LIGHTING 20/1 390 3 845 3 455 20/1 KITCHEN LIGHTING 2 1 LED 65 W 14 ■ <br /> 3 MCA=30 40/3 3108 5 3488 1 380 20/1 (E)GFI ROOF OUTLET 4 3 NIGHT LIGHTING 20/1 130 3 160 3 30 20/1 EXIT LIGHTING 4 PANEL FIXTURE WITH 0 10V 2GTL4 882 EZ1 LP850 <br /> DIMMING DRIVER <br /> 5 3108 5 3358 1 1 250 20/1 HVAC SMOKE DETECTOR 6 5 CAN LIGHTING 20/1 1 24 3 1 274 1 250 20/1 1 RESTROOM GFI 6 <br /> 7 3456 4 3456 8 7 RESTROOM LIGHT&FAN 20/1 431 3 1181 1 750 20/1 CONVENIENCE OUTLETS 8 L) <br /> 9 MCA=26=26 35/3 3456 4 3456 10 9 EC1 -DATA CABINET 20/1 1200 1 1700 1 500 20/1 SHOW WINDOW OUTLETS 10 <br /> MC <br /> 11 3456 4 3456 12 11 CM1 -NEST CAMERAS 20/1 144 1 644 1 500 20/1 PRi/DDi -TICKET PRINTERS 12 2'x4', 5000K 2 <br /> 13 0 14 13 POINT OF SALE OUTLETS 20/1 250 1 850 1 600 20/1 CD1 -POINT OF SALE OUTLETS 14 RECESSED MOUNTED FLAT LITHONIA <br /> 15 0 16 [21 <br /> 780 8 1560 8 780 16 1 NL LED PANEL FIXTURE WITH 0-10V 2GTL4 88L EZ1 LP850 65 W 3 <br /> 17 0 18 M1 -MIXER 20/3 780 8 1560 8 780 20/3 M1 -MIXER 18 DIMMING DRIVER ''❑ <br /> 19 LIGHTING CONTROL PANEL 20/1 100 3 100 20 780 8 1560 8 780 20 UJ W <br /> 21 0 22 M2-MIXER 20/1 1100 8 1825 5 725 20/1 EF-1 I HOOD EXHAUST 22 L LA23 0 24 MUA-MAKE-UP AIR UNIT 20/1 1024 5 1024 24 4" DIAMETER, LED r L1� <br /> 251 0 26 25 FF-1 -AIR CURTAIN 20/1 360 1 1800 8 1440 20/1 Wi -HOT HOLDING CABINET 26 RECESSED MOUNTED LITHONIA [J m co <br /> 27 01 -BAKERY OVEN 20/1 250 1 500 1 250 20/1 01 -BAKERY OVEN 28 27 IPAD OUTLETS 20/1 80 1 1520 8 1440 20/1 Wi -HOT HOLDING CABINET 28 O LED DOWN LIGHT WITH 0-10V WF4 LED 30K4OK50K 10.6 W 4 gOCRI MW W L <br /> r <br /> 29 6240 8 12480 8 6240 30 29 R2-REFRIGERATOR 20/1 242 8 2222 1 1980 20/1 TV55 30 DIMMING DRIVER LL TT <br /> 31 01 -BAKERY OVEN 70/3 6240 8 12480 8 6240 70/3 01 -BAKERY OVEN 32 31 R4-U/C REFRIGERATOR 20/1 265 8 1261 8 996 20/1 MW-MICROWAVE 32 r U� <br /> 33 6000 8 12000 8 6000 34 33 Ri -REFRIGERATOR 20/1 780 8 1776 8 996 20/1 MW-MICROWAVE 34 T '^ <br /> 35 AC-1 SMOKE DETECTOR 20/1 250 1 1 250 36 35 Ri -REFRIGERATOR 20/1 780 8 1776 8 996 20/0 MW-MICROWAVE 36 l u 1 <br /> 37 9273 9273 38 37 RI -REFRIGERATOR 20/1 780 8 1776 8 996 20/1 MW-MICROWAVE 38 2'X4', 5000K LITHONIA V <br /> 39 PANEL B 100/3 9321 9321 40 39 Ri -REFRIGERATOR 20/1 780 8 780 40 RECESSED MOUNTED FLAT 2GTL4 302 EZ1 DRYWALL <br /> ^ <br /> 141 8512 8512 42 41 1012 8 1012 20/1 F2-FREEZER 42 3 LED PANEL FIXTURE WITH 0-10V WITH DGA24 DRYWALL 23.3 W 1 0� v <br /> VA LOAD PER PHASE 28417 28765 28056 VA LOAD PER PHASE 9273 9321 8512 DIMMING DRIVER ADAPTER ❑ <br /> AMPERAGE PER PHASE 236.8 239.7 233.8 AMPERAGE PER PHASE 77.28 77.68 70.93 " ^' <br /> LOAD BALANCE33% 34% 33% LOAD BALANCE 34% 34% 31% ^ ❑ `VV <br /> VA LOAD THIS PANEL 85238 VA LOAD THIS PANEL 27106 ILLUMINATED EGRESS ❑ r <br /> TOTAL PANEL AMPERAGE 236.6 TOTAL PANEL AMPERAGE 75.29 EM1LED WITH 90 U2L <br /> MINUTE BATTERY LITHONIA <br /> 6 W 3 J N X <br /> BACKUP � ❑ W Q <br /> LOAD CALCULATIONSEl 0> o LL <br /> COMBINATION EXIT/ ❑ <br /> DESCRIPTION CODE LOAD ADJUSTED LOAD EM2 LED ILLUMINATED EGRESS LITHONIA 3.8 W 2 �■ Z <br /> WITH 90 MINUTE BATTERY ECR LED M6 RED <br /> RECEPTACLES BACKUP <br /> 100%OF FIRST 10 KVA 1 7994 VA @ 100% 7994 VA <br /> 50%OF REMAINDER 2 0 VA @ 100% 0 VA m W Ln <br /> LIGHTING @ 125% 3 1560 VA @ 125% 1950 VA LIGHTING CONTROL SCHEDULEJ W <br /> MOTOR LOAD- LARGEST @ 125% 4 10368 VA @ 125% 12960 VA <br /> MOTOR LOADS @ 100% 5 11073 VA @ 100% 11073 VA <br /> EQUIPMENT CONTINUOUS @ 125% 6 0 VA @ 125% 0 VA SYMBOL DESCRIPTION MANUFACTURER & QUANTITY DETAIL REMARKS W <br /> EQUIPMENT NON-CONTINUOUS @ 100% 7 0 VA @ 100% 0 VA MODEL NUMBER W <br /> KITCHEN EQUIPMENT @ 65% 8 54243 VA @ 65% 35258 VA <br /> EXISTING LOAD 9 0 VA @ 100% 0 VA <br /> TOTAL 85238 ADJ. TOTAL 69235 WALL MOUNT nLight Air 1 ❑ I Ln <br /> VOLTS 208 OCCUPANCY SENSOR/DIMMING LIGHT SWITCH SENSOR SWITCH WSXA WH Q <br /> PHASE 3 WALL MOUNT nLight Air ^ <br /> CALCUATED AMPS 192.2 ❑D DIMMING LIGHT SWITCH SENSOR SWITCH RPODBA DX WH G2) 3 ❑ O) <br /> �3 WIRELESS 1-ZONE ROOM CONTROLLER nLight Air 1 W W ❑ <br /> RPP20 D G2 I [v <br /> O CEILING MOUNT nLight Air <br /> OS 1 <br /> OCCUPANCY SENSOR RCMSB 7 G2 k I <br /> DS CEILING MOUNT nLight Air 1 a <br /> DAYLIGHT SENSOR RCMSB 7 G2 <br /> FOR NATIONAL LIGHTING LIGHTING ACCOUNT, CONTACT 0 <br /> CRUMBL@CEDNATIONALACCOUNTS.COM <br /> ELECTRICAL ONE - LINE DIAGRAM 562-926-7202 El <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br /> EXISTING D A 13 <br /> R <br /> MAIN SWITCHBOARD TO REMAIN - NO WORK <br /> J <br /> I <br /> ~ C-25449 p <br /> 6-30-21 <br /> M s� RENEWAL DATE <br /> '9T OQ <br /> OF CAL <br /> 200/3 J <br /> • <br /> •0 <br /> - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br /> v <br /> crumbl <br /> cookies <br /> Lu <br /> W Y INTERIOR TENANT <br /> w rr IMPROVEMENT <br /> LL O <br /> o � <br /> Q zz LOCATION <br /> QZ 864 W. BENJAMIN HOLT DR. <br /> z Q STOCKTON, CA <br /> g 95207 <br /> Lu A.P.N.: 09741060 <br /> rr <br /> O O <br /> z <br /> F <br /> U) FRANCHISE OWNER <br /> X <br /> w KTK CO. <br /> 3966 GLEN ABBY CIRCLE <br /> ALL ELECTRICAL EQUIPMENT SHALL BE LABELED, LISTED, OR STOCKTON, CA <br /> CERTIFIED BY A NATIONALLY RECOGNIZED TESTING LABORATORY 95219 <br /> ACCREDITED BY THE UNITED STATES OCCUPATIONAL <br /> SAFETY HEALTH ADMINISTRATION <br /> PANEL SUB <br /> A PANEL <br /> 200 AMP 100 AMP TAF DRAWN <br /> CHECKED <br /> ARC FLASH LABELING REQUIREMENT SLW <br /> PROVIDE THE FOLLOWING LABEL AS A MINIMUM ALL SWITCHBOARDS AND PANEL BOARDS SUPPLIED BY A FEEDER SHALL BE MARKED TO DATE <br /> FOR COMPLIANCE WITH NFPA AND NEC: 1-1/4" C W/(2) #2+ (1) #8 GND INDICATE THE DEVICE OR EQUIPMENT WHERE THE POWER SUPPLY ORIGINATES. 5/25/2021 <br /> SCALE <br /> ® DANGER AS SHOWN <br /> JOB NO. <br /> 21-136 <br /> / ARC FLASH AND SHOCK HAZARD SHEET <br /> FOLLOW ALL REQUIREMENTS IN SERVICE EQUIPMENT SHALL BE LEGIBLY MARKED IN THE FIELD WITH THE MAXIMUM <br /> NFPA 70E FOR SAFE WORK AVAILABLE FAULT CURRENT. THE FIELD MARKING SHALL INCLUDE THE DATE THE <br /> PRACTICES AND FOR PERSONAL FAULT CURRENT CALCULATION WAS PERFORMED AND BE OF SUFFICIENT <br /> PROTECTIVE EQUIPMENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED Eml ol <br /> OF SHEETS <br />