Laserfiche WebLink
REVISIONS BY <br /> Q KEYNOTES <br /> iO ELECTRICAL CONTRACTOR SHALL PROVIDE FUSED DISCONNECTS, MOTOR STARTER, CONTROL <br /> RELAY 120V CONTROL TRANSFORMER, AND CONNECTION TO KITCHEN EXHAUST FAN, AS <br /> DIRECTED BY EQUIPMENT MANUFACTURER <br /> OELECTRICAL CONTRACTOR SHALL PROVIDE FUSED DISCONNECTS, MOTOR STARTER, CONTROL <br /> RELAY 120V CONTROL TRANSFORMER, AND CONNECTION TO KITCHEN MAKE-UP AIR UNIT, AS <br /> DIRECTED BY EQUIPMENT MANUFACTURER <br /> OELECTRICAL CONTRACTOR SHALL VERIFY EXISTING AND/OR PROVIDE FUSED DISCONNECTS, • <br /> MOTOR STARTER, CONTROL RELAY 120V CONTROL TRANSFORMER, AND CONNECTION TO HVAC <br /> UNIT AS DIRECTED BY EQUIPMENT MANUFACTURER <br /> O4 ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING AND/OR PROVIDE WEATHERPROOF/GFI <br /> RECEPTACLE ON ROOF 2 <br /> OELECTRICAL CONTRACTOR SHALL VERIFY EXISTING AND/OR PROVIDE POWER AND CONTROL <br /> CONDUITS, WIRING AND CONNECTION FOR DUCT SMOKE DETECTOR FOR HVAC UNIT AS <br /> DIRECTED BY MECHANICAL CONTRACTOR. DETECTOR SHALL BE FURNISHED BY MECHANICAL W ko <br /> 1 CONTRACTOR, INSTALLED AND CONNECTED BY ELECTRICAL CONTRACTOR. <br /> PROVIDE 20A/1 P ELECTRICALLY HELD CONTACT IN WATERPROOF ENCLOSURE. WIRE TO Ln <br /> CONTROL HVAC UNIT FOR EMERGENCY SHUT DOWN CONTROL BY DUCT SMOKE DETECTOR. L] m ca <br /> i I I LwL u' � <br /> I I r A <br /> a F I I — `` <br /> B-1,3,5 1 <br /> I I I LA <br /> I I <br /> tj 0� <br /> --- W Q 0 <br /> \ n N <br /> --- ---------------------- <br /> n 0 � <br /> F_ X <br /> 3 En <br /> I o w Q <br /> 3 / LL <br /> O ' El o <br /> C0 <br /> (E) (E) Z G <br /> I <br /> F A-1,3,5 F -7.9.11 Q <br /> + ® + ® 00 <br /> m W Ln <br /> 4 m W <br /> 4 1 -3 a/ <br /> J (E) Q <br /> A-4 rA 4� I W N <br /> SD SD <br /> Ll J <br /> - I El 0 z <br /> I L YI <br /> e I r <br /> A-6 5 A-6 i J I a) <br /> W <br /> 01 W 0 <br /> I I <br /> — — <br /> __ ' I 0 N <br /> D %_0 <br /> F = = I I <br /> I o0 <br /> p a <br /> ° 1❑ ❑ 1 <br /> 0000 ;ool <br /> I 0 <br /> 1❑ ❑ 1 HVAC UNIT S C H D E D U LE El <br /> ❑ ❑ i <br /> UNIT VOLOTS/ FLA DISC. FUSE BRANCH CIRCUIT <br /> 1 = =1 i❑ ❑ i ' R C <br /> 1 El Ell D <br /> i ❑ Ell i❑ ❑ i KEF 115/ 1 8.9 20/1 20 1/2" C W/(2)#12+ (1) #12 GND <br /> 1 = 01 I❑ ❑ <br /> I ti <br /> L J II II II I :El ❑ <br /> ' ' <br /> Ji El Ell i❑ El i MUA 115/ 1 13.8 2011 20 1/2" C W/(2)#12+ (1) #12 GND <br /> J L- J L J Ll--!J J 1 ❑ Ell i C-25449 0 <br /> II AC-1 208/3 30 40/3 40 EXISTING TO REMAIN - NO WORK 6-30-21 <br /> I ❑ 1:11I :El El El EI I 1 RENEWAL DATE <br /> a i ❑ ❑i i❑ 11i AC-2 208/3 30 40/3 40 EXISTING TO REMAIN NO WORK 9�F FOS <br /> ® p ❑ i OF CA\-\ <br /> Cl El <br /> ❑ ❑ 1 <br /> 0 i❑ El •• <br /> ® 1❑ ❑ 1 <br /> i❑ ❑ i <br /> V <br /> crumbl <br /> cookies <br /> INTERIOR TENANT <br /> IMPROVEMENT <br /> LOCATION <br /> 864 W. BENJAMIN HOLT DR. <br /> STOCKTON, CA <br /> 95207 <br /> A.P.N.: 09741060 <br /> FRANCHISE OWNER <br /> KTK CO. <br /> 3966 GLEN ABBY CIRCLE <br /> STOCKTON, CA <br /> NOTE 95219 <br /> CONTRACTOR TO VERIFY EXISTING CONDITIONS <br /> IF EXISTING FIXTURES, DUCTWORK AND/OR PIPING LEFT BY PREVIOUS TENANT <br /> MEET THE PERFORMANCE AND ACCESSIBILITY REQUIREMENTS OF BUILDING CODE AND PROJECT <br /> SPECIFICATIONS,EXISTING PIPING, DUCTWORK FIXTURES AND EQUIPMENT MAY BE UTILIZED DRAWN <br /> TAF <br /> NOTIFY ARCHITECT IF REVISIONS AND/OR ADDITIONAL INFORMATION <br /> IS REQUIRED TO MEET PROJECT CRITERIA CHECKED <br /> SLW <br /> PLAN <br /> NORTH DATE <br /> 5/25/2021 <br /> SCALE <br /> �# SEE DRAWING M-1.1 FOR MECHANICAL EQUIPMENT SCHEDULE AS SHOWN <br /> JOB NO. <br /> 21-136 <br /> SHEET <br /> SEE DRAWING E-1.0 FOR ELECTRICAL SYMBOL LEGEND <br /> ELECTRICAL HVAC POWER PLAN SCALE: Em2m2 <br /> 1/4" = 1'-0" <br /> OF SHEETS <br />