REVISIONS BY
<br /> CRUMBL COOKIES STOCKTON
<br /> opa!" San Joaquin County
<br /> z Environmental Health Department ■
<br /> < 1868 E. Hazelton Ave.
<br /> Stockton, CA95205
<br /> (209) 468-8-3420 864 W BENJAMIN H
<br /> i65
<br /> Z p
<br /> APPROVED WITH CONDITIONS STOCKTON , A 95207 -
<br /> 1 0
<br /> For conditions, please see approval letter dated: 6-17-21 U
<br /> DRAWING INDEX Approved by: l�la�(beGGOGII�fGGIGt�L Date: Jure 17, 2021 W W M 00
<br /> Ln
<br /> DESIGN CRITERIA PROJECT DIRECTORY PROJECT INFORMATIONG)
<br /> U
<br /> Q Ln
<br /> Imm U
<br /> GENERAL PROJECT INFORMATION ^
<br /> G0.0 COVER SHEET PLUMBING DRAWINGS APPLICABLE CODE: OWNER MECHANICAL/PLUMBING/ELECTRICAL THESE DRAWINGS ARE PART OF A SET OF CONSTRUCTION DOCUMENTS. THE U
<br /> G1.1 ACCESSIBILITY DETAILS P-1.0 PLUMBING SPECIFICATIONS 2019 CALIFORNIA BUILDING CODE CRUMBL COOKIES ENGINEER CONSTRUCTION DOCUMENTS CONSIST OF ONE OR MORE OF THE FOLLOWING ❑ ❑W
<br /> 2019 CALIFORNIA MECHANICAL CODE KATIE BERTILACCHI THEODORE BRANDVOLD ELEMENTS:
<br /> G1.2 SITE PLAN P-1.1 PLUMBING SCHEDULES 2019 CALIFORNIA PLUMBING CODE (209) 603-5583 COMMERCIAL ARCHITECTURE %_-00rn
<br /> ARCHITECTURAL DRAWINGS P-2.1 WATER PIPING PLAN
<br /> P-2.0 WASTE PIPING PLAN 2019 CALIFORNIA FIRE CODE ca.stockton@crumble.com (209) 571-8158 CONSTRUCTION DRAWINGS UJ
<br /> 2019 CALIFORNIA ENERGY CODE 616 14TH ST. MODESTO, CA SPECIFICATIONS W XJ
<br /> 2019 CALIFORNIA ELECTRIC CODE DESIGN CONSULTANTS STRUCTURAL CALCULATIONS ❑
<br /> A1.1 DEMOLITION PLAN, REMODEL FLOOR PLAN & P-2.2 GAS PIPING PLAN CALIFORNIA RETAIL FOOD CODE JZW ARCHITECTS CONTRACT FORMS AND CONDITIONS Q Q
<br /> RCP P-3.0 PLUMBING DETAILS TYLER WALLES ADDENDA I LL
<br /> ACCESSIBILITY SARA SANDBERG MODIFICATIONS AND REVISIONS 0 ❑
<br /> A2.1 INTERIOR ELEVATIONS 2019 CALIFORNIA BUILDING CODE 45 E. CENTER ST, SUITE 202
<br /> A2.2 INTERIOR ELEVATIONS, ENLARGED RESTROOM ELECTRICAL DRAWINGS NORTH SALT LAKE, UT 84054 CONTRACTORS, SUBCONTRACTORS, AND OTHERS WHO PROVIDE LABOR AND/OR 0 Z
<br /> PLAN (385) 324-9050 MATERIALS REFERENCING THESE DRAWINGS ARE RESPONSIBLE FOR OBTAINING AND
<br /> E-1.0 ELECTRICAL COVER SHEET tylerw@jzw-a.com REVIEWING ALL CURRENT CONSTRUCTION DOCUMENTS.
<br /> A6.1 EQUIPMENT PLAN AND SCHEDULES � mm
<br /> A6.2 DOOR SCHEDULE E-1.1 ELECTRICAL SCHEDULE DEFERRED SUBMITTALS ARCHITECTS OF RECORD CONTRACTORS, SUBCONTRACTORS, AND OTHERS ARE TO REPORT ANY DISCREPANCIES m W
<br /> E-2.0 ELECTRICAL POWER PLAN THEODORE BRANDVOLD OR ERRORS TO ARCHITECTS IMMEDIATELY. ANY CHANGES TO THE PROJECT WILL BE W W LJ
<br /> A6.3 WIRE SHELVING DETAILS E-2.1 ELECTRICAL LIGHTING PLAN COMMERCIAL ARCHITECTURE VERIFIED WITH THE OWNER BY THE ARCHITECT AND REVISIONS WILL BE ISSUED BY W
<br /> A6.4 FINISH PLAN AND DETAILS E-2.2 ELECTRICAL HVAC POWER PLAN LL 0
<br /> (209) 571-8158 ARCHITECT. CONTRACTORS ARE NOT TO MAKE ALTERATIONS OF ANY KIND WITHOUT /
<br /> A7.1 CABINETRY PLAN AND SECTIONS FIRE ALARM SYSTEM 616 14TH ST. MODESTO, CA THE PRIOR WRITTEN CONSENT OF ARCHITECT. DISCREPANCIES NOT REPORTED
<br /> A7.2 SECTIONS AND DETAILS ENERGY CALCULATIONS
<br /> FIRE SPRINKLER SYSTEM IMMEDIATELY ARE RESPONSIBILITY OF CONTRACTOR.
<br /> Q
<br /> A7.3 WALL AND CEILING DETAILS T-24.1 ELECTRICAL POWER DISTRIBUTION TITLE 24 CONTRACTORS SHALL NOT SCALE FROM DRAWINGS. DIMENSIONS ARE PROVIDED TO W r
<br /> CACLULATIONS SCOPE OF W ALLOW FOR ACCURATE CONSTRUCTION OF BUILDING. QUESTIONS ARISING FROM I T
<br /> DIMENSIONS SHOULD BE RESOLVED BY CONTACTING ARCHITECT. C3 'n
<br /> MECHANICAL DRAWINGS T-24.2 INDOOR LIGHTING TITLE 24 CALCULATIONS LI'
<br /> M-1.0 MECHANICAL SPECIFICATIONS T-24.3 MECHANICAL SYSTEMS TITLE 24 N ❑
<br /> M-1.1 MECHANICAL SCHEDULES CALCULATIONS CONSTRUCTION OF INTERIOR PARTITION WALLS,TRANSACTION COUNTERS AND NEW FINISHES, ii rn
<br /> INSTALLATION OF KITCHEN EQUIPMENT AND MECHANICAL, ELECTRICAL AND PLUMBING W C]M-2.0 MECHANICAL PLAN T-24.4 MECHANICAL SYSTEMS TITLE 24 SYSTEMS AS REQUIRED BY RETAIL BAKERY FUNCTIONS AND APPLICABLE CODES. SCOPE OF W I I
<br /> M-3.0 MECHANICA DETAILS CALCULATIONS WORK TO INCLUDE THE REUSE OF ELECTRICAL SERVICE PANEL AND EXISTING ROOF TOP UNIT. W
<br /> � T rN
<br /> M-3.1 MECHANICA DETAILS T-24.5 DOMESTIC WATER HEATING TITLE 24
<br /> .-0
<br /> M-4.0 EXHAUST HOOD SPECIFICATIONS CALULATIONS 'n
<br /> M-4.1 EXHAUST HOOD SPECIFICATIONS T-24.6 PROCESS SYSTEMS TITLE 24 CALCULATIONS W nI
<br /> M-4.2 EXHAUST HOOD SPECIFICATIONS L.L
<br /> GENERAL PROJECT NOTES PROJECT LOCATION CODE ANALYSIS O
<br /> Ll
<br /> CHAPTER 3: OCCUPANCY CLASSIFICATION AND USE
<br /> GENERAL PROJECT NOTES GENERAL FINISH NOTES v /
<br /> 302 CLASSIFICATION. BUSINESS: GROUP B
<br /> 4` ACCESSIBLE 304 BUSINESS GROUP B MSEC AgCy'�
<br /> O ALL DIMENSIONS TO NEW WALLS ARE TO FACE OF STUD UNLESS NOTED OTHERWISE. O ALL INTERIOR WALLS TO BE WRAPPED WITH 5/8" GYPSUM WALL BOARD, TAPED, FILLED, �✓ - PATH TO FOOD PROCESSING ESTABLISHMENTS AND COMMERCIAL \G �J' BR9,�o c,\
<br /> ALL DIMENSIONS TO EXISTING WALLS ARE TO FACE OF FINISH. EXISTING DIMENSIONS AND FINISHED AS PER ROOM FINISH SCHEDULE AND OWNER. - PUBLIC ACCESS KITCHENS NOT ASSOCIATED WITH RESTAURANTS,
<br /> 6-34-21
<br /> WERE PROVIDED BY OWNER. CONTRACTOR TO VERIFY PRIOR TO CONSTRUCTION. % CAFETERIAS AND SIMILAR DINING FACILITIES NOT MORE C-25449
<br /> O
<br /> SEE FLOOR PLANS AND/OR FINISH SCHEDULE FOR FINISH FLOOR MATERIALS. THAN 2,500 SF IN AREA
<br /> O v
<br /> 2
<br /> O CONTRACTOR TO VERIFY EXISTING CONDITIONS. DISCREPANCIES BETWEEN ACTUAL T EN PM\\`�N / \ y �'� RENEWAL
<br /> DAE
<br /> CONDITIONS AND PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. O OWNER TO SELECT ALL HARDWARE, FIXTURES, APPLIANCES, ETC. CONTRACTOR TO \ { �` CHAPTER 6: TYPES OF CONSTRUCTION 9T CPQ
<br /> CONTRACTOR SHALL SUBMIT SPECIFIC DISCREPANCIES FOR ARCHITECT REVIEW. INSTALL AS PER OWNER. ' - ' TYPE V-B SOF CAi-�F
<br /> PROJECT
<br /> O IN ALL AREAS OF CONSTRUCTION. PROTECT ALL EXISTING WALLS, CEILINGS, FLOORING O ALL SPECIAL ACCESSIBILITY FACILITIES SHALL BE IDENTIFIED WITH APPROPRIATE y `� y CHAPTER 9: FIRE PROTECTION AND LIFE SAFETY SYSTEMS
<br /> 3 FINISHES, EQUIPMENT, FURNITURE, ACCESSORIES,AND ALL EXISTING BUILDING 4 SIGNAGE. ' > �� > LOCATION 903 AUTOMATIC SPRINKLER SYSTEM
<br /> ELEMENTS TO REMAIN FROM DAMAGE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR �� ,� , n EXISTING: EQUIPPED WITH AUTOMATIC SPRINKLER
<br /> PATCHING, REPAIR, AND/OR REPLACEMENTS OF ALL SUCH ITEMS AT NO EXPENSE TO O IN ALL AREAS SCHEDULED TO RECEIVE NEW WALL FINISH, CLEAN, PATCH, AND REPAIR &
<br /> �G \ ;\ NFPA 13 FIRE SPRINKLER SYSTEM PROVIDED IN BUILDING
<br /> OWNER IF DAMAGE OCCURS. ALL WALLS IN PREPARATION FOR NEW PAINT OR FINISH. COORDINATE REMOVAL OF ',,
<br /> EXISTING WALL ITEMS AND ACCESSORIES WITH OWNER. `;�, CHAPTER 10: MEANS OF EGRESS
<br /> ® PROVIDE THE FOLLOWING ITEMS TO CONTROL VERMIN AND FLIES: A) AIR CURTAIN AT 4^ c�• \, 1004 OCCUPANT LOAD
<br /> SERVICE ENTRANCES. B)EXTERIOR DOORS SHALL BE SELF CLOSING. C) SEAL ALL © AT WALL TRANSITIONS FROM NEW TO EXISTING WALLS, PATCH REPAIR AND/OR REPLACE :* .. = 1004.5 DESIGN OCCUPANT LOAD -TABLE 1004.5
<br /> EQUIOPMENT TO FLOOR OR WALL GYP. BOARD AS REQUIRED TO PROVIDE FLUSH TRANSITION BETWEEN NEW AND EXISTING
<br /> WALL SURFACES. .. FUNCTION OF SPACE LOAD FACTOR AREA #OCC. crumbL
<br /> O TRASH ENCLOSURE: COORDINATE WITH LOCAL REFUSE COMPANY FOR ADEQUACY OF MERCANTILE: 60 GROSS 152 SF 3
<br /> EXISTING TRASH ENCLOSURE 7 IT IS THE CONTRACTORS RESPONSIBILITY TO COORDINATE AND LOCATE ELECTRICAL, " SR� KITCHENS, COMMERCIAL: 200 GROSS 1031 SF 6 cookies
<br /> T ' .; 'o�
<br /> DATA, AND PHONE RECEPTACLES, SWITCHES, ETC.TO AVOID CASEWORK, DOORS ETC. - OCCUPIED SPACE 1183 SF 9
<br /> © ALL EQUIPMENT SHALL HAVE NSF OR EQUAL APPROVALS a, - = INTERIOR TENANT
<br /> 8 ALL CABINETS SHELVING,TABLES, DISPLAY CASES AND EQUIPMENT SHALL BE ` EMPLOYEE RESTROOM NA 57 SF NA IMPROVEMENT
<br /> ., �'`' `
<br /> CONSTRUCTED OF NON-TOXIC, NON-CORROSIVE, WATERPROOF, WASHABLE MATERIALS.
<br /> ', � , `. TOTAL AREA 1240 SF 9
<br /> GENERAL FRAMING NOTES CONSTRUCTION
<br /> E POSED NAIIL HEADS, ETC AND INSIPQUALITY WITHOUT LOCATION
<br /> INSTALLED MANNER WHICH DOES NOT CREATE NOT TO SCALE �\ 1005 MEANS OF EGRESS SIZING 864 W BENJAMIN HOLT
<br /> O ALL DIMENSIONS AND CONDITIONS TO BE VERIFIED BY CONTRACTOR PRIOR TO ANY WORK. CLEANING PROBLEMS. THEY SHALL BE CAULKED AND COVED WITH A 4" HIGH COVING AT N 1005.2 MINIMUM WIDTH BASED ON COMPONENT STOCKTON, CA 95207
<br /> THE BASE OR INSTALLED ON ROUND APPROVED 6" LEGS. EGRESS PLAN MIN 36" PROVIDED
<br /> O ALL INTERIOR WALLS TO BE 3 5/8" METAL STUDS AT 16" O.C. UNLESS NOTED OTHERWISE. 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
<br /> PROVIDE ALL BACKING FOR EQUIPMENT AS REQUIRED. GENERAL PLUMBING, ELECTRICAL, EQUIPMENT NOTES TABLE 1006.2.1 SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY A.P.N.:
<br /> OCCUPANCY:B
<br /> O ALL WORK SHALL BE IN STRICT ACCORDANCE WITH THE NOTED EDITION OF THE OCCUPANT LOAD OF SPACE: <30
<br /> INTERNATIONAL BUILDING CODE (I.B.C.), AND LOCAL ORDINANCES. O EXISTING CONDITIONS FOR ALL BUILDING SYSTEMS: PLUMBING, MECHANICAL, COMMON PATH OF EGRESS TRAVEL DISTANCE W/ FS: <100FT FRANCHISE OWNER
<br /> ELECTRICAL, SEWER, FIRE PROTECTION, STRUCTURAL, ETC. WERE PROVIDED BY OWNER. F, ONE EXIT REQUIRED FROM EACH SPACE KTK CO
<br /> ALL STRUCTURAL PLYWOOD SHALL BE STRUCTURAL GRADE I OR STRUCTURAL GRADE II. CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION. ° 00 00000 00000 00000 0000- ONE EXIT PROVIDED FROM EACH SPACE CRUMBL COOKIES-
<br /> 0000 00000 00000 00000 1:11:11:11:]E: STOCKTON
<br /> O ALL ELECTRICAL FINISH HARDWARE TO BE SELECTED BY OWNER. I-II _ _ ♦ 2019 CALIFORNIA PLUMBING CODE, CHAPTER 4
<br /> GENERAL THERMAL, MOISTURE,AND ACOUSTICAL PROTECTION NOTES O PROVIDE (2) SEISMIC STRAPS (MIN.) FOR EVERY WATER HEATER. - - -♦� 422 MINIMUM NUMBER OF REQUIRED FIXTURES
<br /> °o°o oo°o° 422.1 FIXTURE COUNT
<br /> °°°° °°°°° MINIMUM NUMBER IN TABLE 422.1
<br /> O AIRTIGHT DRYWALL SYSTEMS SHALL BE USED (USE VAPOR BARRIERS AT ALL EXTERIOR ® IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO ASSURE REQUIRED j� BUSINESS: AuthoN
<br /> WALLS AND CEILINGS). PLUMBING AND ELECTRICAL SERVICE TO ALL FIXTURES AS INDICATED ON PLANS AND I 1 PER 15 FOR FEMALE, FIRST 30
<br /> AS REQUIRED BY BUILDING CODE AND OWNER. - 1 PER 50 FOR MALE, FIRST 100 CHECKED
<br /> O SEAL AROUND ALL ELECTRICAL, PLUMBING, OR MECHANICAL PENETRATIONS AT EXTERIOR _b� 422.2 SEPARATE FACILITIES. Designer
<br /> WALL AND INCEILING/FLOOR OR CEILING ROOF ASSEMBLIES.
<br /> O THE GENERAL CONTRACTOR SHALL VERIFY AND COORDINATE WITH ALL TRADES, SIZES, \ EXCEPTION 3: IN BUSINESS AND MERCHANTILE
<br /> AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, PLUMBING, AND ELECTRICAL OCCUPANCIES WITH TOTAL FLOOR AREA OF 2000 DATE
<br /> O5/25/2021 3:28:44 PM
<br /> ALL EXTERIOR WALL INSULATION TO MATCH EXISTING. EQUIPMENT, EQUIPMENT PADS FOR BASES. AS WELL AS ELECTRIC POWER, WATER AND \ SQUARE FEET OR LESS ONE TOILET FACILITY
<br /> DRAIN INSTALLATIONS, BEFORE PROCEEDING WITH WORK. CONTRACTOR SHALL PROVIDE DESIGNED FOR THE USE BY NO MORE THAN ONE SCALE
<br /> COORDINATION DRAWINGS FOR PROPER PLACEMENT OF ALL TRADES WORK, ANY \� PERSON AT A TIME SHALL SATISFY THE REQUIREMENT AS SHOWN
<br /> CONCERNS, SPACE LIMITATIONS OR STRUCTURAL CONFLICTS, SHALL BE BROUGHT TO PATH OF EGRESS 71'- 0"
<br /> FOR SERVING CUSTOMERS AND EMPLOYEES OF BOTH JOB NO.
<br /> GENERAL DOOR NOTES THE ATTENTION OF THE ARCHITECT, A REASONABLE RESPONSE TIME SHALL BE
<br /> SEXES. 21-0700
<br /> ALLOWED. 7117 ul 2020 CALIFORNIA FOOD CODE, CHAPTER 9 PERMANENT FOOD FACILITIES
<br /> SHEET
<br /> O COORDINATE WITH OWNER FOR DOOR MANUFACTURER. © ILLUMINATION LEVELS SHALL MEET OR EXCEED THE FOLLOWING VALUES FOR FOOD ARTICLE 2.TOILET FACILITIES (b)(1)
<br /> PREPERATION AND STORAGE AREAS ❑ KITCHEN A PERMANENT FOOD FACILITY SHALL PROVIDE CLEAN
<br /> DOORS TO BE SOLID T CORE, PAINT GRADE, COLOR TO BE SELECTED BY OWNER. ElMERCANTILE TOILET FACILITIES FOR CONSUMERS WHEN THERE IS ONSITE CONSUMPTION OF FOODS OR THE FACILITY HAS
<br /> O DOOR HARDWARE TO BE SELECTED BY OWNER. MORE THAN 20,000 SQUARE FEET OF FLOOR SPACE. ■
<br /> OF SHEETS
<br />
|