Laserfiche WebLink
1400 E. Victor Rd, Lodi, CA 95240 PR0529108 <br /> 10/14/2021 Program: APSA <br /> PHOTO 5: <br /> The 01/07/202.1 monthly ins ection checklist was incom lete (page 2 of 2) <br /> Is the primary tank free of water or has another preventative measure been taken? / <br /> 4 NOTE: Refer to paragraphs 6.10 and 6.11 of the standard for alternatives for Category 1 r1Yes ❑No ❑N/A <br /> tanks.N/A is only appropriate for these alternatives. <br /> 5 For double-wall or double bottom tanks or CE-ASTs, is interstitial monitoring equipment <br /> (where applicable)in good working condition? ❑Yes ❑No ❑N/A <br /> 6 For double-wall tanks or double bottom tanks or CE-ASTs,is interstice free of liquid? <br /> Remove the liquid if it is found.If tank product is found,investigate possible leak. ❑Yes ❑No ❑N/A <br /> Equipment on tank <br /> 7 If overfill equipment has a"test'button,does it activate the audible horn or light <br /> to confirm operation?If battery operated,replace battery if needed. As ❑NO A/A <br /> 8 Is overfill prevention equipment in good working condition?If it is equipped with a ( .4Amechanical test mechanism,actuate the mechanism to confirm operation. Q'Yes ❑ NO <br /> 9 Is the spill container(spill bucket)empty,free of visible leaks and in good working <br /> condition? ❑Yes ❑No ❑ N/A <br /> 10 Are piping connections to the tank(valves,fittings,pumps,etc.)free of visible leaks? <br /> Note:if"No",identify location and describe leak. ❑YesENO <br /> 11 Do the ladders/platforms/walkways appear to be secure with no sign of severe corrosion <br /> or damage? ❑Yes4N/A <br /> Containment(Diking/Impounding) <br /> 12 Is the containment free of excess liquid,debris,cracks,corrosion,erosion,fire hazards and <br /> other integrity issues? ❑Yes ❑No ❑N/A <br /> 13 Are dike drain valves closed and in good working condition? ❑Yes ❑No ❑ N/A <br /> 14 Are containment egress pathways clear and any gates/doors operable? ❑Yes ❑No ❑ N/A <br /> Concrete Exterior AST(CE-AST) <br /> 15 Inspect all sides for cracks in concrete. Are there any cracks in the concrete exterior larger <br /> than 1/16"? ❑Yes ❑ No TN/A <br /> 16 Inspect concrete exterior body of the tank for cleanliness,need of coating,or rusting whereapplicable. Tank exterior in acceptable condition? ❑Yes ❑ No Visual inspect all tank top openings including nipples,manways,tank top overfill containers, <br /> and leak detection tubes. Is the sealant between all tank top openings and concrete intact ❑Yes ❑ No <br /> and in good condition? <br /> Other Conditions <br /> 18 Is the system free of any other conditions that need to be addressed for <br /> continued safe operation? ❑Yes ❑ No <br /> Monthly Checklist D.,,,,,-) „F, <br /> VICKY VANG-LEE, EHS Page 5 of 5 <br />