Laserfiche WebLink
EXIST. EXTERIOR WALL D I�VAI1VAV1 <br /> TO REMAIN UU VV 0B I!1/ <br /> Ent rpHses <br /> ® (E) <br /> 601 N. ORO AVENUE <br /> 1 Stockton, CA 95215 <br /> Phone: (209) 298-6818 <br /> LEGEND TO <br /> DEMISING WALL 0 Email: dmworblw(1Dyahoo.com <br /> TO REMAIN <br /> Architecture O Consulting <br /> ® LIGHT FIXTURES EO 181 `4�5� MARC. C <br /> r^ � <br /> EXIST. DEMISING WALL * ■ <br /> C 16716 N0. a <br /> ILLUMINATED EXIT SIGN O TO REMAIN 0,a pOl�_3p, oar <br /> 9� 2 <br /> EMERGENCY LIGHTS WITH BATTERY BACK—UP. CONNECT F oe <br /> Q Op CAV7� <br /> CONNECT LIGHT TO NEAREST UNINTERUPTED POWER <br /> SOURCE <br /> These tlnvhpa are Propertyy rp GMM EMerprLLn, antl ora not to <br /> be repro0u,W, cMnggeetl, copleE, or rwsetl .=t the eapnsutl <br /> MECH. REGISTERS — SEE MECH. DRAWINGS written ronsmt of OMW Enlerprieee. <br /> LEGEND <br /> �X=X" CEILING HT. DESIGNATION; TYP. W-0" A.F.F., U.N.O. 1. EXIST. CEILING TO REMAIN <br /> 2. EXIST. LIGHT FIXTURE <br /> 1� 1•-0 3. NEW LIGHT FIXTURE <br /> O KEYNOTE, SEE THIS SHEET <br /> LUMINAIRE SCHEDULE <br /> SYMBOL MANUFACTUREF CATALOG NO. DESCRIPTION / <br /> T-1 METALUX 24CGFP4540C — 41 WATTS 24"x48" RECESSED SUSPENDED LED LIGHT FIXTURE / <br /> � 1 <br /> NEW (4) FIXTURES — SAVINGS OF AT <br /> 102 LEAST 40% OVER OLD FIXTURES PER <br /> T-1 T-1 141.0(b2liii <br /> O 3O <br /> O 1 <br /> LIGHTING NOTES I Project For <br /> 1. SEE MECHANICAL AND PLUMBING DWGS. FOR NEW WORK. I O T-1 T-t AG Renovation & <br /> 2. THE MEANS OF EGRESS AND EXIT DISCHARGES SHALL BE ILLUMINATED AT 103 3 Improvement <br /> ALL TIMES THAT THE BUILDING IS OCCUPIED. THE MEANS OF EGRESS I 2769 Boeing Way, #100 <br /> ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT CANDLE AT THE Stockton, CA 95206 <br /> WALKING SURFACE. CBC 1008.2.1. THE POWER SUPPLY FOR EGRESS \ Phone: (209) 518-8777 <br /> ILLUMINATION SHALL BE PROVIDED BY THE PREMISES ELECTRICAL SUPPLY. CBC 1008.3. <br /> 3. PROVIDE TACTILE LIGHTING SIGN AT EACH GRADE LEVEL EXTERIOR EXIT O <br /> DOOR. THE NEW SIGN SHALL HAVE THE WORD 'EXIT'. CBC 1011.1. <br /> 4. THE MEANS OF EGRESS AND EXIT DISCHARGE SHALL BE ILLUMINATED AT Project <br /> ALL TIMES THAT THE BUILDING IS OCCUPIED. THE MEANS OF EGRESS Herbalife <br /> ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 FOOT CANDLE AT THE Tenant Improvement <br /> WALKING SURFACE. CBenanmp <br /> C 1008.2.1. <br /> THE POWER SUPPLY FOR EGRESS ILLUMINATION SHALL BE PROVIDED BY THE PREMISES (E) 4120 N. El Dorado Avenue <br /> ELECTRICAL SUPPLY. CBC 1008.3. UI (E) Stockton, CA 95204 <br /> 104 / <br /> EXIST. SUBPANEL: 200A, 120/208V, 30, 4W, <br /> (E) <br /> L R T CIRCUIT E <br /> L q pp E <br /> CIRCUIT <br /> CIR. € O WATTS BREAKER CIR, T C TT WATTS BREAKER Sheet Contents <br /> I� <br /> NO. DESCRIPTION A 8 C POLE AMP NO. DESCRIPTION 0 R A B C POLE AMP 1 <br /> 1 %1ST. OUTLETS 1440 1 20 2 EW OUTLETS 1000 1 20 <br /> 3 LIGHTS, ESH. FAN 8 EMER. LIGHTS 360 1 20 4 EW LIGHTS AT FOOD PREP 192 1 20 LIGHTING PLAN <br /> S MEDICATED LIGHTING SIGNAGE 100 1 20 6 PARE 1 20 <br /> 7 SPARE 1 20 8 PARE 1 20 (E) (E) <br /> 9 SPARE 1 20 10 PARE 1 20 <br /> 11 PARE 1 20 12 PARE 1 20 <br /> 13 SPARE 1 20 14 PARE 1 20 <br /> 15 SPARE 1 20 1 16 SPARE 1 20 <br /> 19 20 DRAWING STATUS DATE <br /> 21 22 <br /> 23 24 <br /> 25 26 ISSUED 1-18-21 <br /> 27 28 <br /> 29 30 <br /> 31 32 1 PLAN REVIEW NO. 1 3-10-21 <br /> 33 34 LIGHTING PLAN <br /> 3s 36 NORTH <br /> 37 EXIST. HVAC UNIT szooI <br /> 38 <br /> 39 S20040 <br /> 41 42TOTAL WATTS PER PHASE: 6820 5560 TOTAL WATTS PER PHASE: 1080 192 0 SCALE: 1/4"=V-0" <br /> TOTAL WATTS = 18,852; THUS, 19 KVA / 0.208 / 1.73 x 125% = 66 AMPS, OK <br /> BUILDING PERMIT NO.: 1902581 <br /> PANEL SCHEDULE <br /> NOT TO SCALE DRAWN BY: NEO CLAYTON <br /> CHECKED BY: OMW <br /> SCALE: AS NOTED <br /> PROJECT NO.: 20-005 <br /> SHEET: <br /> E2 <br />